Stefan Sack

Stefan Sack

Auto-generated profile, based on publicly available information

Stefan Sack

Universitätsklinikum Essen, Klinik für Kardiologie Westdeutsches Herzzentrum Essen, Essen, Germany

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2007 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
MBMarco Budeus
Marco Budeus
PFPeter Feindt
Peter Feindt
EGEmmeran Gams
Emmeran Gams
HWHeinrich Wieneke
Heinrich Wieneke
SSStefan Sack
Stefan Sack
CPChristian Perings
Christian Perings

1 October 2001 in EP Europace
Verified
Journal Article
Open access
PDF file
SSS. Sack
S. Sack
FHF. Heinzel
F. Heinzel
NDN. Dagres
N. Dagres
SES. Enger
S. Enger
AAA. Auricchio
A. Auricchio
RER. Erbel
R. Erbel
Aims: This report describes the initial clinical results with a newly designed guiding catheter and an ‘over the wire’ pacing lead based on angiolasty technology to stimulate the left ventricle using the transvenous route via the coronary sinus (OTW-CV lead). Methods and Results: In 75% of the 15 patients (6 males, 9 females, mean age of 53±9 years) with congestive heart failure, access to coronary sinus required less than 2 min; in one patient, the attempt failed. Mean R wave amplitudes plus or minus the standard deviation, measured at apical, mid-ventricular and basal positions in the anterior (11·4±9·2, 10·8±6·2, 9·3±6·3 mV) and lateral or posterior veins (10·1±10·7, 8·6±6·4, 7·7±4·3 mV) showed a trend favouring the apex without statistical significance. Pacing impedance, measured at the same sites and vein tributaries, ranged from 670±191 to 915±145 ohms. Pacing thresholds measured at apical and mid ventricular sites were significantly lower than at the base in the anterior vein 2·5±2·8 and 2·8±1·8 vs 5·6±2·7 V at 0·5 ms, P< 0·001). Thresholds in the lateral/posterior veins showed a similar trend but did not reach statistical significance (3·0±1·7, 3·6±1·4±1·8 V at 0·5 ms). In patients, in whom thresholds were determined in more than one vein, the ‘best’ mean threshold was 1·6±0·7 V. Conclusion: The new ‘over the wire’ lead and guiding catheter system allows uncomplicated access to the coronary sinus and the depth of the coronary vein tributaries. Left ventricular sensing and pacing thresholds are acceptable for chronic use in implanted cardiac rhythm management systems.

1 August 2005 in Herz
Verified
Journal Article
Closed access
PDF file
SSStefan Sack
Stefan Sack
CNChristoph Naber
Christoph Naber
PKPhilipp Kahlert
Philipp Kahlert
NMNasser Malyar
Nasser Malyar
AGAchim Gutersohn
Achim Gutersohn
RERaimund Erbel
Raimund Erbel

1 September 2005 in Herzschrittmachertherapie + Elektrophysiologie
Verified
Journal Article
Closed access
PDF file
SSS. Sack
S. Sack
AHA. V. Hehn
A. V. Hehn
AKA. Krukenberg
A. Krukenberg
HWHeinrich Wieneke
Heinrich Wieneke
RER. Erbel
R. Erbel

1 February 2001 in Herz
Verified
Journal Article
Closed access
PDF file
SSStefan Sack
Stefan Sack
EMElisabeth Mouton
Elisabeth Mouton
PDPascal Defaye
Pascal Defaye
NDNikolaos Dagres
Nikolaos Dagres
UWUlrich Wolfhard
Ulrich Wolfhard
OGon behalf of the AIDA Multicenter Study Group
on behalf of the AIDA Multicenter Study Group

24 August 2007 in Intensivmedizin und Notfallmedizin
Verified
Journal Article
Closed access
PDF file
SSStefan Sack
Stefan Sack
PKPhilipp Kahlert
Philipp Kahlert
SPSebastian Philipp
Sebastian Philipp
EKEva Kottenberg-Assenmacher
Eva Kottenberg-Assenmacher
SCSophia Churzidse
Sophia Churzidse
RERaimund Erbel
Raimund Erbel