7 July 2023 in Medical Image Analysis
1 August 2022 in Current Directions in Biomedical Engineering
In this work we present a four compartment mathematical lung model to simulate the local gas exchange based on electrical impedance tomography (EIT) input. The model simulates the local and global time course of the volume, the gas fraction in the alveoli and the arterial partial pressure. The regional information about the distribution of ventilation and perfusion is extracted from EIT data. In order to illustrate the suitability of this approach, an ARDS patient is simulated. The results show good agreement with measurement data for large portions of the time and seem promising e.g. for the use in medical decision support systems.
1 May 2024 in at - Automatisierungstechnik
Expiratory flow limitation (EFL) is an often unrecognized clinical condition with a multitude of negative implications. A mathematical EFL model is proposed to detect flow limitations automatically. The EFL model is a switching one-compartment lung mechanics model with a volume-dependent airway resistance to simulate the dynamic behavior during expiration. The EFL detection is based on a breath-by-breath model parameter identification and validated on clinical data of mechanically ventilated patients. In the severe flow limitation group 93.9 % ± 5 % and in the no limitation group 10.2 % ± 13.7 % of the breaths are detected as EFL. Based on the high detection rate of EFL, these results support the usefulness of the EFL detection. It is a first step toward an automated detection of EFL in clinical applications and may help to reduce underdiagnosis of EFL.
19 March 2026 in Computer Methods and Programs in Biomedicine
Patient-ventilator interaction critically influences the safety and effectiveness of mechanical ventilation, particularly under support modes such as pressure support ventilation (PSV). This study introduces a mathematical model of the respiratory center that integrates chemical feedback, mechanical feedback, and reflex mechanisms to simulate spontaneous breathing and its interaction with a mechanical ventilator. The model incorporates O2 and CO2 chemoreflexes, mechanical feedback, and neural control circuits. Simulation studies evaluated the model's performance under hypercapnia, hypoxia, varying PSV levels, and different types of patient-ventilator asynchrony, comparing outcomes to published literature data. The model accurately reproduced respiratory rate and tidal volume responses with mean absolute percentage errors below 12%, and generated asynchrony frequencies within a 5% acceptance margin. Characteristic ventilatory patterns and emergent asynchronies appeared naturally, without explicit programming of events, demonstrating the physiological plausibility of the model. This respiratory center model provides a robust tool for investigating respiratory control, testing ventilator strategies, and supporting the development of intelligent ventilation approaches, including in silico clinical trials. Its ability to reproduce both normal and pathological ventilatory patterns underscores its potential for translational and clinical research applications.