3 July 2024 in IEEE Access
X-ray imaging plays a pivotal role in clinical diagnostics by facilitating tasks ranging from organ segmentation to disease detection. With the integration of artificial intelligence (AI), the capabilities of X-ray analysis have been greatly enhanced. However, acquiring a comprehensive dataset for training AI models remains challenging due to various factors including patient privacy, radiation exposure, and cost constraints. To overcome this hurdle, researchers have turned to create synthetic X-ray datasets. In dental imaging, the synthesis of Panoramic X-rays (PXs) poses unique challenges owing to the intricate nature of the oral cavity and the inherent diversity among patients. Existing efforts predominantly rely on Cone Beam Computed Tomography (CBCT) or phantoms for such tasks. Synthesizing PX can be beneficial when the PX imaging cannot be performed immediately or when dentists need to find a one-to-one correspondence between PX and CBCT. This review paper comprehensively examines the methodologies employed for synthesizing dental PXs, specifically, automated synthesis, elucidating the methods utilized and the associated advantages, limitations, and potential clinical applications in routine practice. By shedding light on these approaches, this review aims to provide valuable insights for researchers and practitioners in the dental imaging domain.
26 May 2025 in IEEE Access
Panoramic X-ray (PX) is the most widely used imaging modality in dental health care. However, PXs can be severely degraded due to artifacts such as ghostly shadows, distortions, and superimposition of adjacent structures. Panoramic tomosynthesis from cone-beam computed tomography (CBCT) can be considered an alternative to noisy PX. Traditional cylinder-based methods take orthogonal projections along an appropriate dental arch; however, they suffer from a significant discrepancy between synthesized and genuine PXs, making them less applicable for clinical purposes. Recently, another approach based on simulated geometry that emulates the X-ray source-detector movement of PX scanners for ray tracing has been proposed. However, their methods suffer from poorly fitted ray trajectories for individual patients, uneven ray tracing, image misalignment, and, in some cases, the need for prior information on scan parameters. To tackle those problems, we propose a robust method of synthesizing PXs from CBCT by defining a universally applicable simulated geometry of the ray trajectory. Our method adjusts the ray trajectory to be optimal for a patient’s jaw shape and also achieves uniform ray sampling throughout the patient’s jaw by progressively increasing ray sampling intervals. In addition, tilt correction was applied to alleviate potential errors caused by incorrect patient positioning. Quantitative and qualitative results show that our method outperforms prior SA-based methods as well as image processing methods. Our framework can synthesize realistic PX images from dental CBCT by employing efficient ray tracing strategies customized to the patient’s oral structure without the need for scan parameters and ultimately empower dentists’ diagnostic capabilities.
24 September 2025 in IEEE Access
Panoramic radiography (PX) is widely used in dentistry but provides only a flattened 2D view; Cone Beam Computed Tomography CT (CBCT) recovers 3D anatomy at higher dose and cost. We tackle full 3D reconstruction from a single real-world PX for varying patients. We propose ViT–NeBLa (Vision-Transformer Neural Beer–Lambert), a physics-guided framework that estimates a continuous 3D dentoalveolar density field directly from single PX. The design mirrors panoramic acquisition while simplifying the inverse problem: we parameterize projection-ray directions by tangency to a patient-adaptive elliptical path and independently restrict sampling to a jaw-focused horseshoe (focal trough) in which the projection rays do not intersect. This removes the intermediate density-aggregation step used by overlapping-ray methods and reduces per-ray samples by about 52%, lowering memory and compute. A hybrid ViT–CNN backbone extracts global anatomical context and local texture from the PX, and a learnable multi-resolution hash positional encoding maps 3D sample coordinates to expressive features that preserve fine dental and osseous detail. Per-point densities are predicted by a compact MLP and accumulated into a coarse 3D grid, which a lightweight 3D U-Net refines into the final volume. Training is end-to-end using synthetic PX rendered from CBCT via the Beer–Lambert law together with voxelwise, projection-consistency, and perceptual losses; at inference, a single PX is processed directly—without CBCT flattening or dental-arch priors. Experiments show that ViT–NeBLa outperforms contemporary PX-to-3D baselines both quantitatively and qualitatively, yielding sharper cortical boundaries, clearer trabecular patterns, and fewer artifacts. In sum, ViT–NeBLa provides a radiation-efficient route to clinically informative 3D visualization from routine panoramic radiographs while simplifying geometry, reducing sampling, and preserving high-frequency structure.
23 February 2023 in TechRxiv
Panoramic Radiography and Cone Beam Computed Tomography (CBCT) are the most used imaging techniques for implant treatment and oral surgery. However, it cannot be used frequently due to the high cost and radiation exposure of CBCT. Whereas Panoramic x-rays do not provide the high dimensional information necessary for planning surgery. Our research aims to produce an automated method for reconstructing a 3D dental structure from a single panoramic X-ray. This paper presents a robust preprocessing pipeline of CBCT data which are exploited to train a deep learning model for reconstructing the 3D dental structure from a single 2D panoramic X-ray image. It includes a method of generating a pair of synthetic panoramic X-rays and the corresponding flattened 3D volume as ground truth from CBCT data.