Pierre Gebhardt

Pierre Gebhardt

Auto-generated profile, based on publicly available information

Pierre Gebhardt

Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
DSDavid Schug
David Schug
VNVanessa Nadig
Vanessa Nadig
BWBjoern Weissler
Bjoern Weissler
PGPierre Gebhardt
Pierre Gebhardt
VSVolkmar Schulz
Volkmar Schulz
For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3mm × 3mm × 5mm LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds (D T1) in the timing branch from vth t1 = 5-30. The overvoltage was varied in a range of 1.25 V-7.25 V. The ambient temperature was kept at 16 ∘C. For all measurements, we performed an energy calibration including a correction for saturation. We evaluated the energy resolution, the coincidence resolving time (CRT) and the coincidence rate. At an overvoltage of 6 V, we obtained an energy resolution of about 10% FWHM, a CRT of approximately 210 ps FWHM and 400 ps FWTM, the coincidence rate showed only small variations of about 5%. To investigate the influence of the ambient temperature, it was varied between 12 ∘C-20 ∘C. At 12 ∘C and an overvoltage of 6.5 V, a CRT of approx. 195 ps FWHM and an energy resolution of about 9.5% FWHM could be measured. Observed satellite peaks in the time difference spectra were investigated in more detail. We could show that the location of the satellite peaks is correlated with a programmable delay element in the trigger circuit.

1 February 2016 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
PDPeter M Düppenbecker
Peter M Düppenbecker
BWBjoern Weissler
Bjoern Weissler
PGPierre Gebhardt
Pierre Gebhardt
DSDavid Schug
David Schug
JWJakob Wehner
Jakob Wehner
VSVolkmar Schulz
Volkmar Schulz
Advances in solid-state photon detectors paved the way to combine positron emission tomography (PET) and magnetic resonance imaging (MRI) into highly integrated, truly simultaneous, hybrid imaging systems. Based on the most recent digital SiPM technology, we developed an MRI-compatible PET detector stack, intended as a building block for next generation simultaneous PET/MRI systems. Our detector stack comprises an array of 8 × 8 digital SiPM channels with 4 mm pitch using Philips Digital Photon Counting DPC 3200-22 devices, an FPGA for data acquisition, a supply voltage control system and a cooling infrastructure. This is the first detector design that allows the operation of digital SiPMs simultaneously inside an MRI system. We tested and optimized the MRI-compatibility of our detector stack on a laboratory test bench as well as in combination with a Philips Achieva 3 T MRI system. Our design clearly reduces distortions of the static magnetic field compared to a conventional design. The MRI static magnetic field causes weak and directional drift effects on voltage regulators, but has no direct impact on detector performance. MRI gradient switching initially degraded energy and timing resolution. Both distortions could be ascribed to voltage variations induced on the bias and the FPGA core voltage supply respectively. Based on these findings, we improved our detector design and our final design shows virtually no energy or timing degradations, even during heavy and continuous MRI gradient switching. In particular, we found no evidence that the performance of the DPC 3200-22 digital SiPM itself is degraded by the MRI system.

23 January 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
KKKarl Krueger
Karl Krueger
FMFlorian Mueller
Florian Mueller
PGPierre Gebhardt
Pierre Gebhardt
BWBjoern Weissler
Bjoern Weissler
DSDavid Schug
David Schug
VSVolkmar Schulz
Volkmar Schulz
In modern large-scale PET systems, transferring the digitized raw detector data at high count rates to a centralized processing unit is a challenge. Processing data on FPGAs close to the detectors can reduce data early on and improve scalability of the PET system. We present and evaluate an FPGA implementation of gradient tree boosting (GTB) for one-dimensional position estimation of gamma interactions in the scintillator. GTB is a supervised machine learning algorithm based on building ensembles of binary decision trees. Models were trained offline and inferred in an FPGA (XC7K410T-2FFG676 Kintex-7). Input features and GTB parameters influencing both positioning performance and model size were varied while evaluating the inferred models concerning data throughput and FPGA resource consumption as well as positioning performance. We achieved throughputs per detector between 2.94 × 106 and 4.55 × 106 gamma interactions per second. For an optimized GTB model, resource consumption could be reduced by factors of 17 and 10 to less than 1% (2.51 × 103 look-up tables) of available logic and 1.26% (20 BRAMs) of memory resources, while maintaining a positioning performance of 98.63% when compared to the model with the best positioning performance. The presented framework can be easily adapted to other photosensors and scintillator configurations.

12 January 2024 in Medical Physics
Verified
Journal Article
Open access
YKYannick Kuhl
Yannick Kuhl
FMFlorian Mueller
Florian Mueller
SNStephan Naunheim
Stephan Naunheim
MBMatthias Bovelett
Matthias Bovelett
JLJanko Lambertus
Janko Lambertus
VSVolkmar Schulz
Volkmar Schulz
Background: Preclinical research and organ‐dedicated applications use and require high (spatial‐)resolution positron emission tomography (PET) detectors to visualize small structures (early) and understand biological processes at a finer level of detail. Researchers seeking to improve detector and image spatial resolution have explored various detector designs. Current commercial high‐resolution systems often employ finely pixelated or monolithic scintillators, each with its limitations.Purpose: We present a semi‐monolithic detector, tailored for high‐resolution PET applications with a spatial resolution in the range of 1 mm or better, merging concepts of monolithic and pixelated crystals. The detector features LYSO slabs measuring (24 × 10 × 1) mm3, coupled to a 12 × 12 readout channel photosensor with 4 mm pitch. The slabs are grouped in two arrays of 44 slabs each to achieve a higher optical photon density despite the fine segmentation.Methods: We employ a fan beam collimator for fast calibration to train machine‐learning‐based positioning models for all three dimensions, including slab identification and depth‐of‐interaction (DOI), utilizing gradient tree boosting (GTB). The data for all dimensions was acquired in less than 2 h. Energy calculation was based on a position‐dependent energy calibration. Using an analytical timing calibration, time skews were corrected for coincidence timing resolution (CTR) estimation.Results: Leveraging machine‐learning‐based calibration in all three dimensions, we achieved high detector spatial resolution: down to 1.18 mm full width at half maximum (FWHM) detector spatial resolution and 0.75 mm mean absolute error (MAE) in the planar‐monolithic direction, and 2.14 mm FWHM and 1.03 mm MAE for DOI at an energy window of (435–585) keV. Correct slab interaction identification in planar‐segmented direction exceeded 80%, alongside an energy resolution of 12.7% and a CTR of 450 ps FWHM.Conclusions: The introduced finely segmented, high‐resolution slab detector demonstrates appealing performance characteristics suitable for high‐resolution PET applications. The current benchtop‐based detector calibration routine allows these detectors to be used in PET systems.

11 February 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PGP Gebhardt
P Gebhardt
BLB Lavin
B Lavin
APAlkystis Phinikaridou
Alkystis Phinikaridou
JMJ MacKewn
J MacKewn
MHMarkus Henningsson
Markus Henningsson
RBRene Botnar
Rene Botnar
Objective. In preclinical research, in vivo imaging of mice and rats is more common than any other animal species, since their physiopathology is very well-known and many genetically altered disease models exist. Animal studies based on small rodents are usually performed using dedicated preclinical imaging systems with high spatial resolution. For studies that require animal models such as mini-pigs or New-Zealand White (NZW) rabbits, imaging systems with larger bore sizes are required. In case of hybrid imaging using positron emission tomography (PET) and magnetic resonance imaging (MRI), clinical systems have to be used, as these animal models do not typically fit in preclinical simultaneous PET-MRI scanners. Approach. In this paper, we present initial imaging results obtained with the Hyperion IID PET insert which can accommodate NZW rabbits when combined with a large volume MRI RF coil. First, we developed a rabbit-sized image quality phantom of comparable size to a NZW rabbit in order to evaluate the PET imaging performance of the insert under high count rates. For this phantom, radioactive spheres with inner diameters between 3.95 and 7.86 mm were visible in a warm background with a tracer activity ratio of 4.1 to 1 and with a total 18F activity in the phantom of 58 MBq at measurement start. Second, we performed simultaneous PET-MR imaging of atherosclerotic plaques in a rabbit in vivo using a single injection containing 18F-FDG for detection of inflammatory activity, and Gd-ESMA for visualization of the aortic vessel wall and plaques with MRI. Main results. The fused PET-MR images reveal 18F-FDG uptake within an active plaques with plaque thicknesses in the sub-millimeter range. Histology showed colocalization of 18F-FDG uptake with macrophages in the aortic vessel wall lesions. Significance. Our initial results demonstrate that this PET insert is a promising system for simultaneous high-resolution PET-MR atherosclerotic plaque imaging studies in NZW rabbits.