7 July 2022 in IEEE Transactions on Industrial Electronics
With the performance of micromechanical gyroscopes approaching navigation grade, the scale factor nonlinearity is gradually becoming the limitation for high-performance applications such as the satellite attitude measurement. Coupling errors caused by parasitic capacitance are the major sources of scale factor nonlinearity but are usually neglected. In this article, the parasitic-capacitance coupling errors are introduced into the traditional gyroscope model and the scale factor nonlinearity induced by the coupling errors has been analyzed theoretically. The analysis indicates that two parasitic-capacitance couples from sense excitation signal to drive or sense detection signal are the dominant causes of scale factor nonlinearity. Two measurements (i.e., the amplitude of driving excitation signal and axis tuning voltage) are used to realize the calibration of coupling errors with the least square method. The experiment is also carried out to verify this novel calibration method on a navigation-grade honeycomb disk resonator gyroscope. The experimental results demonstrate that the coupling errors have decreased by 87.5 and 44.5 times, respectively, after the error compensation and that the scale factor nonlinearity has been improved from 244.8 ppm to 29.00 ppm. Furthermore, this calibration method can be applied to other resonator gyroscopes with the similar structure and control scheme.
1 February 2023 in Journal of Microelectromechanical Systems
5 October 2022 in IEEE Sensors Journal
This article presents a novel self-calibration method to improve the scale factor (SF) stability by the synchronous control on the first-order and third-order harmonic components of nonlinear detection. On the conventional scheme of a drive loop, the readout amplitude of the first-order harmonic component is controlled at a constant value. However, the actual vibration amplitude of drive-mode motion would drift due to the change of circuit gains between the readout amplitude and actual amplitude, thereby resulting in the deterioration of the SF stability. The third-order harmonic component of nonlinear detection shares the same circuit with the vibration signal, indicating that its readout amplitude can track the change in circuit gains in real time. Therefore, this new approach replaces the original fixed reference with the varying readout amplitude of the third-order harmonic component to eliminate the drive-mode vibration error and eventually calibrate the drift of SF. Experiments performed on a honeycomb disk resonator gyroscope (HDRG) have demonstrated the feasibility of the calibration method. The calibration based on the harmonic extraction yields a short-term SF repeatability of 24.9 ppm and a long-term SF repeatability of 30.8 ppm. Allan deviation analysis of the calibrated SF demonstrates a 3.5-ppm precision upon an average of 200 s. The temperature sensitivity of the SF is reduced from 717.3 ppm/°C to 5.02 ppm/°C and the SF repeatability is improved from 15643 ppm to 94.9 ppm over the temperature range of −30 °C to 30 °C.