Peng Wang

Peng Wang

Auto-generated profile, based on publicly available information

Peng Wang

College of Intelligence Science, National University of Defense Technology, Changsha, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PWPeng Wang
Peng Wang
QLQingsong Li
Qingsong Li
YXYi Xu
Yi Xu
YZYongmeng Zhang
Yongmeng Zhang
XXXiang Xi
Xiang Xi
DXDingbang Xiao
Dingbang Xiao
With the performance of micromechanical gyroscopes approaching navigation grade, the scale factor nonlinearity is gradually becoming the limitation for high-performance applications such as the satellite attitude measurement. Coupling errors caused by parasitic capacitance are the major sources of scale factor nonlinearity but are usually neglected. In this article, the parasitic-capacitance coupling errors are introduced into the traditional gyroscope model and the scale factor nonlinearity induced by the coupling errors has been analyzed theoretically. The analysis indicates that two parasitic-capacitance couples from sense excitation signal to drive or sense detection signal are the dominant causes of scale factor nonlinearity. Two measurements (i.e., the amplitude of driving excitation signal and axis tuning voltage) are used to realize the calibration of coupling errors with the least square method. The experiment is also carried out to verify this novel calibration method on a navigation-grade honeycomb disk resonator gyroscope. The experimental results demonstrate that the coupling errors have decreased by 87.5 and 44.5 times, respectively, after the error compensation and that the scale factor nonlinearity has been improved from 244.8 ppm to 29.00 ppm. Furthermore, this calibration method can be applied to other resonator gyroscopes with the similar structure and control scheme.

20 September 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
LCLiangqian Chen
Liangqian Chen
TMTongqiao Miao
Tongqiao Miao
QLQingsong Li
Qingsong Li
PWPeng Wang
Peng Wang
XWXuezhong Wu
Xuezhong Wu
DXDingbang Xiao
Dingbang Xiao
In recent years, the application prospects of high-precision MEMS gyroscopes have been shown to be very broad, but the large temperature drift of MEMS gyroscopes limits their application in complex temperature environments. In response to this, we propose a method that combines mode reversal and real-time multiple regression compensation to compensate for the temperature drift of gyroscope bias. This method has strong adaptability to the environment, low computational cost, the algorithm is online in real time, and the compensation effect is good. The experimental results show that under the temperature cycle of −20~20 °C and the temperature change rate of 4 °C/min, the method proposed in this paper can reduce the zero-bias stability from about 27.8°/h to 0.4527°/h, and the zero-bias variation is reduced from 65.88°/h to 1.43°/h. This method improves the zero-bias stability of the gyroscope 61-fold and the zero-bias variation 46-fold. Further, the method can effectively suppress the zero-bias drift caused by the heating of the gyroscope during the start-up phase of the gyroscope. The zero-bias stability of the gyroscope can reach 0.0697°/h within 45 min of starting up, and the zero-bias repeatability from 0 to 5 min after startup is reduced from 0.629°/h to 0.095°/h.

1 February 2023 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
PWPeng Wang
Peng Wang
QLQingsong Li
Qingsong Li
YZYongmeng Zhang
Yongmeng Zhang
YWYulie Wu
Yulie Wu
XWXuezhong Wu
Xuezhong Wu
DXDingbang Xiao
Dingbang Xiao

5 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PWPeng Wang
Peng Wang
QLQingsong Li
Qingsong Li
YZYongmeng Zhang
Yongmeng Zhang
XXXiang Xi
Xiang Xi
YWYulie Wu
Yulie Wu
DXDingbang Xiao
Dingbang Xiao
This article presents a novel self-calibration method to improve the scale factor (SF) stability by the synchronous control on the first-order and third-order harmonic components of nonlinear detection. On the conventional scheme of a drive loop, the readout amplitude of the first-order harmonic component is controlled at a constant value. However, the actual vibration amplitude of drive-mode motion would drift due to the change of circuit gains between the readout amplitude and actual amplitude, thereby resulting in the deterioration of the SF stability. The third-order harmonic component of nonlinear detection shares the same circuit with the vibration signal, indicating that its readout amplitude can track the change in circuit gains in real time. Therefore, this new approach replaces the original fixed reference with the varying readout amplitude of the third-order harmonic component to eliminate the drive-mode vibration error and eventually calibrate the drift of SF. Experiments performed on a honeycomb disk resonator gyroscope (HDRG) have demonstrated the feasibility of the calibration method. The calibration based on the harmonic extraction yields a short-term SF repeatability of 24.9 ppm and a long-term SF repeatability of 30.8 ppm. Allan deviation analysis of the calibrated SF demonstrates a 3.5-ppm precision upon an average of 200 s. The temperature sensitivity of the SF is reduced from 717.3 ppm/°C to 5.02 ppm/°C and the SF repeatability is improved from 15643 ppm to 94.9 ppm over the temperature range of −30 °C to 30 °C.