26 January 2007 in Magnetic Resonance in Medicine
Brain water proton (1H2O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5‐mm midventricular axial slice was sampled using a modified Look‐Locker technique with 1.5 mm in‐plane resolution, and 32 time points post‐adiabatic inversion. The results confirmed that for most brain tissues, T1 values increased by more than a factor of 3 between 0.2T and 7T, and over this range were well fitted by T1 (s) = 0.583(B0)0.382, T1(s) = 0.857(B0)0.376, and T1(s) = 1.35(B0)0.340 for white matter (WM), internal GM, and blood 1H2O, respectively. The ventricular cerebrospinal fluid (CSF) 1H2O T1 value did not change with B0, and its average value (standard deviation (SD)) across subjects and magnetic fields was 4.3 (±0.2) s. The tissue 1/T1 values at each field were well correlated with the macromolecular mass fraction, and to a lesser extent tissue iron content. The field‐dependent increases in 1H2O T1 values more than offset the well‐known decrease in typical MRI contrast reagent (CR) relaxivity, and simulations predict that this leads to lower CR concentration detection thresholds with increased magnetic field. Magn Reson Med 57:308–318, 2007.
1 February 1990 in Magnetic Resonance in Medicine
2 October 2000 in Magnetic Resonance in Medicine
21 November 2003 in Magnetic Resonance in Medicine
Contrast reagents (CRs) may enter the tissue interstitium for a period after a vascular bolus injection. As the amount of interstitial CR increases, the longitudinal relaxographic NMR “shutter‐speed” (T–1) for the equilibrium transcytolemmal water exchange process increases. The quantity T–1 is given by |r1o[CRo] + R1o0 – R1i| (where r1o and [CRo] represent the interstitial (extracellular) CR relaxivity and concentration, respectively, and R1o0 and R1i are the extra‐ and intracellular 1H2O relaxation rate constants, respectively, in the absence of exchange). The increase of T–1 with [CRo] causes the kinetics of the water exchange equilibrium to appear to decrease. Here, analytical theory for two‐site‐exchange processes is combined with that for pharmacokinetic CR delivery, extraction, and distribution in a method termed BOLus Enhanced Relaxation Overview (BOLERO©). The shutter‐speed effect alters the shape of the bolus‐tracking (B‐T) time‐course. It is shown that this is mostly accounted for by the inclusion of only one additional parameter, which measures the mean intracellular lifetime of a water molecule. Simulated and real data demonstrate that the effect of shutter‐speed variation on pharmacokinetic parameters can be very significant: neglecting this effect can lead to an underestimation of the parameter values by 50%. This phenomenon can be heterogeneous. Within a tiny gliosarcoma implanted in the rat brain, the interstitial CR in the tumor core never rises to a level sufficient to cause apparent slowing of the exchange process. However, within the few microns needed to reach the proliferating rim, this occurs to a significant degree. Thus, even relative pharmacokinetic quantities can be incorrectly represented in a parametric map that neglects this effect. The BOLERO analysis shows promise for in vivo vascular phenotyping in pathophysiology. It also includes a provision for approximating the separation of the perfusion and permeability contributions to CR extravasation. Magn Reson Med 50:1151–1169, 2003.
20 August 2003 in Magnetic Resonance in Medicine
This report describes the measurement of water preexchange lifetimes and intra/extracellular content in intact, functioning mammalian brain. Intra‐ and extracellular water magnetic resonance (MR) signals from rat brain in vivo were quantitatively resolved in the longitudinal relaxation domain following administration of an MR relaxation agent into the extracellular space. The estimated intracellular water content fraction was 81% ± 8%, and the intra‐ to extracellular exchange rate constant was 1.81 ± 0.89 s–1 (mean ± SD, N = 9), corresponding to an intracellular water preexchange lifetime of ∼550 ms. These results provide a temporal framework for anticipating the water exchange regime (fast, intermediate, or slow) underlying a variety of compartment‐sensitive measurements. The method also supplies a means by which to evaluate membrane water permeability and intra/extracellular water content serially in intact tissue. The data are obtained in an imaging mode that permits detection of regional variations in these parameters. Magn Reson Med 50:493–499, 2003.