1 December 2012 in The Journal of the Acoustical Society of America
The recording of auditory brainstem response (ABR) at high stimulation rates is of great interest in audiology. It allows a more accurate diagnosis of certain pathologies at an early stage and the study of different mechanisms of adaptation. This paper proposes a methodology, which we will refer to as randomized stimulation and averaging (RSA) that allows the recording of ABR at high stimulation rates using jittered stimuli. The proposed method has been compared with quasi-periodic sequence deconvolution (QSD) and conventional (CONV) stimulation methodologies. Experimental results show that RSA provides a quality in ABR recordings similar to that of QSD and CONV. Compared with CONV, RSA presents the advantage of being able to record ABR at rates higher than 100 Hz. Compared with QSD, the formulation of RSA is simpler and allows more flexibility on the design of the pseudorandom sequence. The feasibility of the RSA methodology is validated by an analysis of the morphology, amplitudes, and latencies of the most important waves in ABR recorded at high stimulation rates from eight normal hearing subjects.
1 February 2010 in Ear & Hearing
Objective: In this study, we analyze how electrically evoked compound action potential (ECAP) responses can be used to assess whether electrodes should be activated in the map and to estimate C levels in the Med-El Tempo+ Cochlear Implant Speech Processor. Design: ECAP thresholds were measured using the ECAP Recording System of the Pulsar CI100 implant. Twenty-one postlingually and 28 prelingually deafened patients participated in this study. The relationship between ECAP responses and the activation of electrodes was analyzed. Because an error in the estimation of T levels (behavioral thresholds) has less effect on hearing quality than an error in the estimation of C levels in the Tempo+ cochlear implant speech processor (maximum comfort levels), correlation and regression analyses were performed between ECAP thresholds and C levels. Results: The observation of an evoked potential generally implied that the electrode was activated because only 3.5% of electrodes that yielded measurable evoked responses were deactivated, because of collateral stimulations or an unpleasant hearing sensation. In contrast, the absence of an evoked potential did not imply that an electrode should be deactivated, because 20% of these electrodes provided a useful auditory sensation. ECAP responses did not predict the absolute behavioral comfort levels because of the excessive error between behavioral C levels and those derived from ECAP thresholds (the mean relative error is 43.78%). However, by applying a normalization procedure, ECAP measurements allowed the C-level profile to be predicted with a mean relative error of 6%; that is, they provided useful data to determine the C level of each electrode relative to the average C level of the patient. Conclusions: ECAP is a reliable and an useful objective measurement that can assist in the fitting of the Tempo+ cochlear implant speech processor. From results presented in this work, a protocol is proposed for fitting this cochlear implant system. This protocol facilitates appropriate cochlear implant fitting, particularly for children or uncooperative patients.
28 June 2013 in IEEE Geoscience and Remote Sensing Letters
This letter presents a novel picking algorithm which allows an automated determination of the P-phase onset time. The algorithm includes an adaptive multiband processing and noise-reduction techniques to allow a confident onset time estimation in signals strongly affected by background and/or nonstationary noise processes. Results using a set of 3780 computer-generated earthquake-like signals show that the accuracy is much better than that achieved by conventional STA/LTA algorithm. In addition, the accuracy of the proposed method is improved when it is combined with an autoregressive method. An application of the algorithm to a set of 400 natural earthquakes confirms that the combination of both algorithms provides a precise P-phase onset time estimation in real environments, overcoming the limitations associated with the autoregressive method.
1 February 2014 in Journal of Volcanology and Geothermal Research
1 January 2012 in Clinical and Experimental Otorhinolaryngology
The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor.
26 October 2015 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Detection and classification of the different seismic events are important tasks in volcanological observatories. Trying to make these an automatic process is fundamental for the volcanological community. It is crucial to choose how the seismic signal is represented in terms of parameters or features useful for dealing with the automatic classification problem, since the number and type of parameters could be really large leading to the curse of dimensionality issue. Machine learning theory establishes that in order to build a classifier from a labeled database, there should be a compromise between the complexity of the classifier and the size of the database. Since generating a manually labeled database is a tedious work performed by specialists in volcanology, the size of the databases limits the complexity of the classification systems built by them. On the other hand, if the databases could be represented by a reduced, but relevant, number of features, the complexity of the classifier would be simplified. In order to study the problem just described, this paper performs a comparative study of different classical techniques of dimensionality reduction (DR) of the feature set. The algorithms implemented include feature selection techniques as wrappers and filters and methods which directly transform the original feature space into another with lower dimension. All algorithms have been tested using an automatic classification system of volcano-seismic events. The best results have been obtained with the discriminative feature selection (DFS) algorithm which belongs to the set of wrapper methods.