Ben Petrovic

Ben Petrovic

Auto-generated profile, based on publicly available information

Ben Petrovic

Department of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge UB8 3PH, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2023 in Chemical Engineering Research and Design
Verified
Journal Article
Open access
MGMikhail Gorbounov
Mikhail Gorbounov
BPBen Petrovic
Ben Petrovic
SOSerap Ozmen
Serap Ozmen
PCPeter Clough
Peter Clough
SSSalman Masoudi Soltani
Salman Masoudi Soltani

6 June 2022 in South African Journal of Chemical Engineering
Verified
Journal Article
Open access
MGMikhail Gorbounov
Mikhail Gorbounov
JTJess Taylor
Jess Taylor
BPBen Petrovic
Ben Petrovic
Salman Masoudi SoltaniSalman Masoudi Soltani
Salman Masoudi Soltani

12 June 2019 in Processes
Verified
Journal Article
Open access
PDF file
BPBen Alexanda Petrovic
Ben Alexanda Petrovic
Salman Masoudi SoltaniSalman Masoudi Soltani
Salman Masoudi Soltani
The potential of carbon capture and storage to provide a low carbon fossil-fueled power generation sector that complements the continuously growing renewable sector is becoming ever more apparent. An optimization of a post combustion capture unit employing the solvent monoethanolamine (MEA) was carried out using a Taguchi design of experiment to mitigate the parasitic energy demands of the system. An equilibrium-based approach was employed in Aspen Plus to simulate 90% capture of the CO2 emitted from a 600 MW natural gas combined-cycle gas turbine power plant. The effects of varying the inlet flue gas temperature, absorber column operating pressure, amount of exhaust gas recycle, and amine concentration were evaluated using signal to noise ratios and analysis of variance. The optimum levels that minimized the specific energy requirements were a: flue gas temperature = 50 °C; absorber pressure = 1 bar; exhaust gas recirculation = 20% and; amine concentration = 35 wt%, with a relative importance of: amine concentration > absorber column pressure > exhaust gas recirculation > flue gas temperature. This configuration gave a total capture unit energy requirement of 5.05 GJ/tonneCO2, with an energy requirement in the reboiler of 3.94 GJ/tonneCO2. All the studied factors except the flue gas temperature, demonstrated a statistically significant association to the response.