19 April 2022 in IEEE Transactions on Industrial Electronics
Fault localization is one of the most important issues for modular multilevel converters (MMCs) consisting of numerous switches. This article proposes an isolation forest (IF) based submodule (SM) switch open-circuit fault localization method for MMCs. Based on the continuous sampling SM capacitor voltages, a number of isolation trees (ITs) are produced to construct the IFs for MMCs. Through the comparison of continuous IFs’ outputs, the faulty SM can be effectively localized. The proposed IF-based fault localization method only requires SM capacitor voltages in the MMC to construct concise low-data-volume tree models, and uses sparsity and difference properties of outlier data to localize fault, and accordingly it simplifies calculation complexity. In addition, it does not require the MMC's mathematical models and manual setting of empirical thresholds. Simulation and experiment are conducted, and the results confirm the effectiveness of proposed method.
14 March 2019 in Chemical Communications
Vertical channels with expanded interlayer spacing based on a MoS2/Gr/C composite have been designed. This structure can simultaneously shorten the pathway of Li-ion diffusion across the electrode and enhance the kinetics of Li-ion intercalation/deintercalation within the bulk electrode. Thus, it exhibits a high rate performance and long cycle life in Li-ion batteries.
17 May 2023 in ACM Transactions on Design Automation of Electronic Systems
Power integrity analysis is an essential step in power distribution network (PDN) sign-off to ensure the performance and reliability of chips. However, with the growing PDN size and increasing scenarios to be validated, it becomes very time- and resource-consuming to conduct full-stack PDN simulation to check the power integrity for different test vectors. Recently, various works have proposed machine learning–based methods for PDN power integrity prediction, many of which still suffer from large training overhead, inefficiency, or non-scalability. Thus, this article proposed an efficient and scalable framework for the worst-case power integrity prediction, which can handle general tasks including dynamic noise prediction and bump current prediction. The framework first reduces the spatial and temporal redundancy in the PDN and input current vector and then employs efficient feature extraction as well as a novel convolutional neural network architecture to predict the worst-case power integrity. Experimental results show that the proposed framework consistently outperforms the commercial tool and the state-of-the-art machine learning method with only 0.63–1.02% mean relative error and 25–69× speedup for noise prediction and 0.22–1.06% mean relative error and 24–64× speedup for bump current prediction.
31 December 2021 in ACM Journal on Emerging Technologies in Computing Systems
Pathology image segmentation is an essential step in early detection and diagnosis for various diseases. Due to its complex nature, precise segmentation is not a trivial task. Recently, deep learning has been proved as an effective option for pathology image processing. However, its efficiency is highly restricted by inconsistent annotation quality. In this article, we propose an accurate and noise-tolerant segmentation approach to overcome the aforementioned issues. This approach consists of two main parts: a preprocessing module for data augmentation and a new neural network architecture, ANT-UNet. Experimental results demonstrate that, even on a noisy dataset, the proposed approach can achieve more accurate segmentation with 6% to 35% accuracy improvement versus other commonly used segmentation methods. In addition, the proposed architecture is hardware friendly, which can reduce the amount of parameters to one-tenth of the original and achieve 1.7× speed-up.
19 March 2026 in ACM Transactions on Design Automation of Electronic Systems
With escalating power integrity challenges in advanced technologies, acquiring accurate dynamic power supply noise through Dynamic Voltage Drop (DVD) analysis becomes increasingly demanding. As noise margins shrink, the use of Value Change Dump (VCD) files for precise DVD analysis is indispensable but computationally expensive. Furthermore, the substantial storage requirements of VCD files, which record digital waveforms from logical simulations, pose significant challenges. In this article, we propose a machine learning (ML)-assisted VCD processing framework to accelerate DVD analysis and improve data efficiency. Transitions recorded in VCD files are mapped to a Physical Design-Aware Circuit Hierarchy Tree (CHT) for efficient feature extraction. These features are leveraged by an XGBoost-based predictor to identify critical vector time windows within the VCD, significantly reducing simulation complexity. Additionally, Huffman encoding is applied to compress signal names, further optimizing storage utilization. Experimental results show that DVD analysis using our profiled VCD files achieves a speedup of approximately 3.53× with an error margin of only 3.89%.