Jelena Kršić

Jelena Kršić

Auto-generated profile, based on publicly available information

Jelena Kršić

National Institute of the Republic of Serbia, University of Belgrade

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
VDViktor Domazetoski
Viktor Domazetoski
GGGoran Gligoric
Goran Gligoric
MMMilan Marinković
Milan Marinković
ASAlexei Shvilkin
Alexei Shvilkin
JKJelena Krsic
Jelena Krsic
MIMarija Ivanovic
Marija Ivanovic

3 June 2024 in IEEE Access
Verified
Journal Article
Open access
MMMarjan N. Miletić
Marjan N. Miletić
VAVladimir Atanasoski
Vladimir Atanasoski
PBPetra P. Beličev
Petra P. Beličev
GGGoran M. Gligorić
Goran M. Gligorić
URUroš M. Ralević
Uroš M. Ralević
BVBranislav Vajdić
Branislav Vajdić
Clinical outcomes of several acute conditions, including myocardial infarction (MI), the most common cause of death, can be improved by timely diagnostics based on electrocardiography (ECG). However, current diagnostic technologies include a large number of wired ECG electrodes, which require accurate placement by trained personnel. The ideal ECG device would be suitable for self-measurement, i.e., would have a small number of electrodes, be mobile or portable, and provide an accurate diagnosis. However, these aims have not been met using the same device. A recently developed handheld ECG device with three quasi-orthogonal leads opened the door for mobile assessment of the three-dimensional cardiac vector by self-measurement. We hypothesize that the information provided is sufficient for accurate reconstruction of the 12-lead ECG. We propose a reconstruction algorithm based on the segment-by-segment 4-matrix (4M) transformation applied to the P wave, QRS complex, ST segment, and T wave. The accuracy of the 4M method was tested using data obtained from 64 healthy volunteers. The 4M method reconstructed the standard 12-lead ECG with a 0.96 mean cross-correlation for all leads and provided meaningful clinical results. A back-to-back comparative study demonstrated the superiority of the proposed method over the traditional EASI method. In addition, the results provide evidence of the capability of the 3-lead 4M technology to accurately reconstruct the full cardiac vector from a single measurement, which distinguishes it from competition. Although further clinical investigation is necessary, wireless operation and high accuracy make the proposed method potentially suitable for remote monitoring and self-assessment.

22 March 2023 in Optics & Laser Technology
Verified
Journal Article
Closed access
JPJ. Petrovic
J. Petrovic
JKJ. Kršić
J. Kršić
AMAleksandra Maluckov
Aleksandra Maluckov
JVJ.J.P. Veerman
J.J.P. Veerman

1 October 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JKJelena Kršić
Jelena Kršić
MSMirjana G. Stojanović
Mirjana G. Stojanović
MMMarjan N. Miletić
Marjan N. Miletić
VAVladimir Atanasoski
Vladimir Atanasoski
MIMarija Ivanovic
Marija Ivanovic
JPJovana Petrović
Jovana Petrović

1 January 2025 in Facta universitatis - series: Physics, Chemistry and Technology
Verified
Journal Article
Open access
JKJelena Krsic
Jelena Krsic
AMAleksandra Maluckov
Aleksandra Maluckov
DSDanka B. Stojanović
Danka B. Stojanović
MIMarija Ivanovic
Marija Ivanovic
JPJovana Petrovic
Jovana Petrovic
In this study, we explore diverse rhythms of heart activity through the lens of complexity, shedding light on the intricate dynamics of heart rate variability and the amplitude of ECG signals. Metrics such as heart rate variability, Shannon entropy, and the quantities realted to Poincar? section distinctly differentiate between bradycardia, normal rhythm, and tachycardia. Our findings indicate an increase in complexity, progressing from ECGs with sinus rhythm, through those with atrial flutter, to ECGs exhibiting atrial fibrillation.

1 January 2025
Verified
Conference Paper
Closed access
UVUniverzitet u Beogradu Institut za nuklearne nauke Vinča
Univerzitet u Beogradu Institut za nuklearne nauke Vinča
JKJelena Kršić
Jelena Kršić
AMAleksandra Maluckov
Aleksandra Maluckov
DSDanka B. Stojanović
Danka B. Stojanović
VAVladimir Atanasoski
Vladimir Atanasoski
JPJovana Petrović
Jovana Petrović
U ovom radu istražujemo različite srčane ritmove primenom formalizma i teorije kompleksnih sistema na EKG signale. Rezultati pokazuju da se metrike zasnovane na RR intervalima, varijabilnost srčanog ritma i Šenonova entropija, mogu koristiti za razlikovanje periodičnih od neperiodičnih ritmova, dok se periodični ritmovi dodatno klasifikuju po frekvenciji srčanih otkucaja. Veličine koje u obzir uzimaju i amplitude signala, kao što su parametri Poenkareovih dijagrama i multifraktalnih spektara, daju nove informacije i indikatore kompleksnosti EKG signala, te predstavljalju potencijalne nove biomarkere aritmija. Prikazani rezultati predstavljaju korak ka sistematičnom povezivanju dinamičkih parametara EKG signala sa biomarkerima korisnim u kliničkoj praksi.