Gideon Shafir

Gideon Shafir

Auto-generated profile, based on publicly available information

Gideon Shafir

Faculty of Medicine, Tel Aviv University , P.O.B 39040 Ramat Aviv, Tel Aviv 69978 , Israel

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
NPNili Schamroth Pravda
Nili Schamroth Pravda
YSYonatan Shaleve
Yonatan Shaleve
YPYgal Plakht
Ygal Plakht
GSGideon Shafir
Gideon Shafir
TGTzlil Grinberg Tzlil Grinberg
Tzlil Grinberg Tzlil Grinberg
AHAshraf Hamdan
Ashraf Hamdan
We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003–27.244, P = 0.003). Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.

1 January 2022 in The American Journal of Cardiology
Verified
Journal Article
Closed access
Arthur ShiyovichArthur Shiyovich
Arthur Shiyovich
YPYgal Plakht
Ygal Plakht
YHYoav Hammer
Yoav Hammer
YAYaron Aviv
Yaron Aviv
MWMaya Wiessman
Maya Wiessman
AHAshraf Hamdan
Ashraf Hamdan