Hossein Aslian

Hossein Aslian

Auto-generated profile, based on publicly available information

Hossein Aslian

Department of Physics, University of Trieste, Trieste, Italy

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
HAHossein Aslian
Hossein Aslian
Mahdi SadeghiMahdi Sadeghi
Mahdi Sadeghi
SMseied rabi mehdi mahdavi
seied rabi mehdi mahdavi
FMFarshid Babapour Mofrad
Farshid Babapour Mofrad
MAMahdi Astarakee
Mahdi Astarakee
PFPedram Fadavi
Pedram Fadavi

11 April 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
HAHossein Aslian
Hossein Aslian
TKTomas Kron
Tomas Kron
TWTroy Watts
Troy Watts
CACagla Akalanli
Cagla Akalanli
NHNicholas Hardcastle
Nicholas Hardcastle
MSMara Severgnini
Mara Severgnini
Purpose: This study focused on determining risks from stereotactic radiotherapy using flattening filter‐free (FFF) beams for patients with cardiac implantable electronic device (CIEDs). Two strategies were employed: a) a retrospective analysis of patients with CIEDs who underwent stereotactic radiosurgery (SRS)/SBRT at the Peter MacCallum Cancer Centre between 2014 and 2018 and b) an experimental study on the impact of FFF beams on CIEDs.Methods: A retrospective review was performed. Subsequently, a phantom study was performed using 30 fully functional explanted CIEDs from two different manufacturers. Irradiation was carried out in a slab phantom with 6‐MV and 10‐MV FFF beams. First, a repetition‐rate test (RRT) with a range of beam pulse frequencies was conducted. Then, multifraction SBRT (48 Gy/4 Fx) and single‐fraction SBRT (28 Gy/1 Fx) treatment plans were used for lung tumors delivered to the phantom.Results: Between 2014 and 2018, 13 cases were treated with an FFF beam (6 MV, 1400 MU/min or 10 MV, 2400 MU/min), and 15 cases were treated with a flattening filter (FF) beam (6 MV, 600 MU/min). All the devices were positioned outside the treatment field at a distance of more than 5 cm, except for one case, and no failures were reported due to SBRT/SRS. In the phantom rep‐rate tests, inappropriate sensing occurred, starting at a rep‐rate of 1200 MU/min. Cardiac implantable electronic device anomalies during and after delivering VMAT‐SBRT with a 10‐MV FFF beam were observed.Conclusions: The study showed that caution should be paid to managing CIED patients when they undergo SBRT using FFF beams, as it is recommended by AAPM TG‐203. Correspondingly, it was found that for FFF beams although there is small risk from dose‐rate effects, delivering high dose of radiation with beam energy greater than 6 MV and high‐dose rate to CIEDs positioned in close vicinity of the PTV may present issues.

1 January 2018 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
MAMehdi Astaraki
Mehdi Astaraki
MSMara Severgnini
Mara Severgnini
VMVittorino Milan
Vittorino Milan
ASAnna Schiattarella
Anna Schiattarella
FCFrancesca Ciriello
Francesca Ciriello
HAHossein Aslian
Hossein Aslian
In radiation therapy, defining the precise borders of cancerous tissues and adjacent normal organs has a significant effect on the therapy outcome. Deformable models offer a unique and robust approach to medical image segmentation. The objective of this study was to investigate the reliability of segmenting organs-at-risk (OARs) using three well-known local region-based level-set techniques. A total of 1340 non-enhanced and enhanced planning computed tomography (CT) slices of eight OARs (the bladder, rectum, kidney, clavicle, humeral head, femoral head, spinal cord, and lung) were segmented by using local region-based active contour, local Chan-Vese, and local Gaussian distribution models. Quantitative metrics, namely Hausdorff Distance (HD), Mean Absolute Distance (MAD), Dice coefficient (DC), Percentage Volume Difference (PVD) and Absolute Volumetric Difference (AVD), were adopted to measure the correspondence between detected contours and the manual references drawn by experts. The results showed the feasibility of using local region-based active contour methods for defining six of the OARs (the bladder, kidney, clavicle, humeral head, spinal cord, and lung) when adequate intensity information is available. While the most accurate results were achieved for lung (DC = 0.94) and humeral head (DC = 0.92), a poor level of agreement (DC < 0.7) was obtained for both rectum and femur. Incorporating local statistical information in level set methods yields to satisfactory results of OARs delineation when adequate intensity information exists between the organs. However, the complexity of adjacent organs and the lack of distinct boundaries would result in a considerable segmentation error.

4 April 2019 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
HAHossein Aslian
Hossein Aslian
TKTomas Kron
Tomas Kron
FLFrancesco Longo
Francesco Longo
RRRoya Rad
Roya Rad
MSMara Severgnini
Mara Severgnini


1 April 2013 in Radiation Measurements
Verified
Journal Article
Closed access
NKNavid Khaledi
Navid Khaledi
AAAzim Arbabi
Azim Arbabi
DSDariush Sardari
Dariush Sardari
SMseied rabi mehdi mahdavi
seied rabi mehdi mahdavi
HAHossein Aslian
Hossein Aslian
KSKourosh Sheibani
Kourosh Sheibani