Anemia is more often seen in older patients. As the mean age of hip fracture patients is rising, anemia is common in this population. Allogeneic blood transfusion (ABT) and anemia have been pointed out as possible risk factors for poorer outcome in hip fracture patients.
One of the disadvantages of the Impact Factor (IF) is self-citation. The SCImago Journal Rank (SJR) indicator excludes self-citations and considers the quality, rather than absolute numbers, of citations of a journal by other journals. The present study re-evaluated the influence of self-citation on the 2007 IF for 18 major orthopaedic journals and investigated the difference in ranking between IF and SJR.
Delirium in patients with hip fractures lead to higher morbidity and mortality. Prevention in high-risk patients by prescribing low dose haloperidol is currently under investigation.
Femoroacetabular impingement (FAI) is caused by an anatomic deviation of the acetabular rim or proximal femur, which causes chronic groin pain. Radiological identification of FAI can be challenging. Advances in imaging techniques with the use of computed tomography (CT) scan enable 3D simulation of FAI. We made an experimental cadaveric validation study to validate the 3D simulation imaging software. The range of motion (ROM) of five cadaveric hips was measured using an electromagnetic tracking system (EMTS). Specific marked spots in the femur and pelvis were created as reproducible EMTS registration points. Reproducible motions were measured. Hips were subsequently imaged using high-resolution CT after introduction of artificial cam deformities. A proprietary software tool was used, Articulis (Clinical Graphics) to simulate the ROM during the presence and absence of the induced cam deformities. According to the EMTS, 13 of the 30 measured ROM end-points were restricted by > 5° due to the induced cam deformities. Using Articulis, with the same 5° threshold, we correctly detected 12 of these 13 end point limitations and detected no false positives. The median error of the measured limitations was 1.9° (interquartile range 1.1° - 4.4°). The maximum absolute error was 5.4°. The use of this dynamic simulation software to determine the presence of motion limiting deformities of the femoroacetabular is validated. The simulation software is able to non-invasively detect a reduction in achievable ROM, caused by a cam type deformity.
Background: A discussion is ongoing whether displaced femoral neck fractures in elderly patients should be treated with a non-cemented or a cemented hemiarthroplasty. A recent Cochrane analysis stresses the importance of further research into the relative merits of these techniques. We hypothesise that non-cemented hemiarthroplasty will result in at least the same technical-functional outcome and complication rate, with a shorter operation time. Methods and design: A randomised controlled multicentre trial will be performed. The study population consists of 200 patients of 70 years and older. Patients with a displaced femoral neck fracture will be allocated randomly to have a cemented or a non-cemented hemiarthroplasty. Data will be collected preoperatively, immediately postoperatively, and 6 weeks, 3 months and 1 year postoperatively. The main outcome measures of this study are technical-functional results of the hemiarthroplasty, duration of surgery, complications, and mid-thigh pain. Secondary outcome measures are living conditions at final follow up, self-reported health-related quality of life, and radiological evaluation of the hemiarthroplasty. Conclusion: A recent Cochrane analysis did not find arguments in favour of either non-cemented or cemented hemiarthroplasty. The forthcoming trial will compare treatment for a displaced femoral neck fracture by cemented versus non-cemented hemiarthroplasty. Our results will be published as soon as they become available. Trial Registration: Trial Registration Number NTR1508