1 January 2018 in Ultrasonography
The aim of this study was to evaluate the correlations between laboratory findings and ultrasonographic measurements of renal length and cortical thickness in patients receiving follow-up for chronic kidney disease (CKD). A total of 41 CKD patients (18 males and 23 females; mean age, 65.2 years; range, 42 to 85 years) with a low glomerular filtration rate who did not require renal replacement therapy were included in this prospective study. Patients were followed up with laboratory assays at bimonthly intervals and with ultrasonography performed twice a year. Renal cortical thickness, renal length, and estimated glomerular filtration rate (eGFR) values were compared using the paired-samples t test. Additionally, Pearson correlation analysis was conducted between renal length and cortical thickness measurements and eGFR values to assess kidney function. At the beginning of the study and after 24 months, mean eGFR values of the 41 patients were 35.92 mL/min and 28.38 mL/min, respectively. The mean renal length was 91.29 mm at the beginning of the study and 90.24 mm at the end of the study. The mean cortical thickness was 5.76±2.05 mm at the beginning of the study and 5.28±1.99 mm at the end of the study. A statistically significant positive association was found between eGFR and mean renal length (r=0.66, P<0.01) and between eGFR and mean cortical thickness (r=0.85, P<0.01), with the latter being more prominent. Our study suggests that ultrasonographic cortical thickness measurements may be an important imaging technique in the follow-up care of patients with CKD.
1 February 2016 in Diagnostic and Interventional Imaging
7 June 2014 in Japanese Journal of Radiology
24 March 2025 in IEEE Access
Automated classification of fetal movements in ultrasound (US) videos is critical for assessing fetal well-being and detecting potential complications during pregnancy. This study introduces FetalMovNet, a novel deep learning model that incorporates an attention mechanism to improve the classification of fetal movement in US video sequences. The model integrates convolutional neural networks (CNN) for feature extraction and an attention mechanism to capture spatio-temporal patterns, significantly improving classification performance of fetal movements. To evaluate FetalMovNet, we construct a new dataset containing fetal movements in US across seven different anatomical structures-head, body, arm, hand, heart, leg, and foot. Experimental results show that FetalMovNet achieves an accuracy of 0.9887, precision of 0.9871, recall of 0.9910, and an F1-score of 0.9891, outperforming state-of-the-art CNN and CNN-LSTM architectures. Ablation studies confirm the effectiveness of the attention mechanism, with FetalMovNet achieving an area under curve (AUC) score of 0.9957, compared to 0.9471 for CNN and 0.9543 for CNN-LSTM. The proposed FetalMovNet model provides a robust and clinically applicable tool for real-time fetal movement monitoring, reducing the need for manual assessment and improving prenatal care.
19 September 2014 in Wiener klinische Wochenschrift
26 June 2021 in European Journal of Science and Technology
Analyzing medical images and videos with computer-aided algorithms provides important benefits in the diagnosis and treatment of diseases. Especially in recent years, the increasing developments in deep learning algorithms have provided continuous improvement in subjects such as speed, performance and hardware need in the processing of medical data. Examination of medical data, which may require advanced expertise, using deep learning algorithms has begun to be widely used as a secondary tool in the decision-making process of physicians. Tracking the movements of the fetus and recognizing its planes in ultrasound (US) videos is an important parameter in evaluating the health of the baby. In this study, a YOLOv5 deep learning network based method is proposed to identify fetal anatomical planes from fetal ultrasound and to detect their movements. First of all, a dataset of videos containing 16-20 weeks of fetal movements is created in the study. In the next step, the fetal head, arm, heart and body are identified and tracking using the deep-SORT algorithm on the labeled data. In the experimental studies conducted on ultrasound videos within the scope of the study, using the YOLOv5 algorithm, head, body, heart and arm are recognized with 95.04%, 94.42%, 88.31% and 83.23% F1-score, respectively. In addition, ultrasonic video movements of the head, heart and body of the fetus are followed and the trajectories and patterns of the movements are extracted. Thus, the detection of fetal movements from the movement patterns transformed into a two-dimensional plane is achieved.