Sigfrid D. Soli

Sigfrid D. Soli

Auto-generated profile, based on publicly available information

Sigfrid D. Soli

House Ear Institute, Los Angeles, USA

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in International Journal of Audiology
Verified
Journal Article
Closed access
SSSigfrid D. Soli
Sigfrid D. Soli
LWLena L.N. Wong
Lena L.N. Wong
This overview focused on a number of factors that must be considered when measuring speech intelligibility in noise. In addressing each factor, a number of considerations and assumptions must be made. This paper attempts to identify each of the considerations and assumptions underlying the HINT. By so doing, the user is made aware of the strengths and limitations of this approach to the assessment of speech intelligibility in noise. In the following short reports, relevant details about the development and normalization of the HINT materials in each language are provided. Ongoing research with additional languages is expected to produce new HINT materials with measurement characteristics similar to those described herein. © 2008 British Society of Audiology, International Society of Audiology, and Nordic Audiological Society.link_to_subscribed_fulltex

9 February 2010 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
JAJustin M. Aronoff
Justin M. Aronoff
YYYang-Soo Yoon
Yang-Soo Yoon
DFDaniel J. Freed
Daniel J. Freed
AVAndrew J. Vermiglio
Andrew J. Vermiglio
IPIvan Pal
Ivan Pal
SSSigfrid D. Soli
Sigfrid D. Soli
While considerable evidence suggests that bilateral cochlear implant (CI) users’ sound localization abilities rely primarily on interaural level difference (ILD) cues, and only secondarily, if at all, on interaural time difference (ITD) cues, this evidence has largely been indirect. This study used head-related transfer functions (HRTFs) to independently manipulate ITD and ILD cues and directly measure their contribution to bilateral CI users’ localization abilities. The results revealed a strong reliance on ILD cues, but some CI users also made use of ITD cues. The results also suggest a complex interaction between ITD and ILD cues.

1 January 2008 in International Journal of Audiology
Verified
Journal Article
Closed access
JCJenny C.Y. Chan
Jenny C.Y. Chan
DFDaniel J. Freed
Daniel J. Freed
AVAndrew J. Vermiglio
Andrew J. Vermiglio
SSSigfrid D. Soli
Sigfrid D. Soli
Binaural abilities are difficult to assess, yet important to understand, in the course of rehabilitating bilateral cochlear implantees. One purpose of this research was to develop a binaural assessment methodology using direct electrical input to the cochlear implant, ‘‘direct connect assessment’’, pre-processed by appropriate headrelated transfer functions (HRTFs) to simulate the binaural cues for spatial release from masking and sound localization. A second purpose was to create and evaluate new, modified rules for adaptively measuring the speech reception threshold in noise with the Hearing In Noise Test (HINT) for use with cochlear implant subjects. A third purpose was to develop a new sound localization protocol whose difficulty is adjusted to the sound localization ability of the individual cochlear implant subject. These new protocols were combined with the direct connect method and evaluated in acoustic hearing subjects and cochlear implant subjects. HINT thresholds and sound localization scores measured in the sound field and with the direct connect method did not differ significantly and were highly correlated in both groups. Measures of spatial release from masking, head shadow effects, binaural squelch, and binaural summation derived from the thresholds also were comparable for both methods. The alternative adaptive rules for HINT were found to measure different points on the same performance-intensity function. These rules allowed all cochlear implant subjects in the study to be tested adaptively and their thresholds to be compared to norms. Sound localization was measured successfully in all subjects with a sector localization protocol whose difficulty is to be adjusted to the localization ability of the subject. This protocol reduced by one-third to one-half the time required to complete the assessment of the localization ability.

9 April 2012 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
JAJustin M. Aronoff
Justin M. Aronoff
DFDaniel J. Freed
Daniel J. Freed
LFLaurel M. Fisher
Laurel M. Fisher
IPIvan Pal
Ivan Pal
SSSigfrid D. Soli
Sigfrid D. Soli
Bilateral cochlear implant patients are unable to localize as well as normal hearing listeners. Although poor sensitivity to interaural time differences clearly contributes to this deficit, it is unclear whether deficits in terms of interaural level differences are also a contributing factor. In this study, localization was tested while manipulating interaural time and level cues using head-related transfer functions. The results indicate that bilateral cochlear implant users’ ability to localize based on interaural level differences is actually greater than that of untrained normal hearing listeners.

1 January 2008 in International Journal of Audiology
Verified
Journal Article
Closed access
SSSigfrid D. Soli
Sigfrid D. Soli
(2008). Some thoughts on communication handicap and hearing impairment. International Journal of Audiology: Vol. 47, No. 6, pp. 285-286.

22 August 2012 in International Journal of Audiology
Verified
Journal Article
Closed access
YZYun Zheng
Yun Zheng
GLGang Li
Gang Li
ZMZhao-Li Meng
Zhao-Li Meng
KXKe Xu
Ke Xu
YTYong Tao
Yong Tao
SSSigfrid D. Soli
Sigfrid D. Soli
Objective: Perform longitudinal evaluations of young children during the first 12 months after initial hearing-aid fitting. Document evidence of early prelingual auditory development (EPLAD), identify factors that affect EPLAD, and define performance milestones that can guide best practices. Design: Unblinded, prospective, within-subject, repeated-measures design. Audiological measures and measures of EPLAD were taken at baseline, 3, 6, and 12 months after hearing-aid fitting. Study sample: Subjects were 45 pediatric patients initially fitted with hearing aids between 1 and 5.5 years of age. Four groups were formed for analysis purposes based on severity of hearing loss (moderate-to-severe and profound) and initial fitting age (≤ 30 months and > 30 months). Results: All groups exhibited statistically significant increases in EPLAD within six months of hearing-aid fitting, and those with profound losses exhibited further statistically significant improvement between six and 12 months. Similar EPLAD levels were reached at 12 months regardless of severity of hearing loss. The EPLAD trajectory is similar to that following early cochlear implantation. Conclusions: Measures of EPLAD provide a means of evaluating outcomes following early pediatric hearing-aid intervention, supplementing behavioral audiological measures.