1 April 2002 in EP Europace
Arrhythmias are common problems in hypertensive patients. The presence and complexity of both supraventricular and ventricular arrhythmias may influe
17 November 2010 in EP Europace
AimsThe growing problem with endocardial lead infections and lead malfunctions has increased the interest in percutaneous lead removal technology. In this report, we present our initial experience in percutaneous lead extraction with a novel hand-powered sheath, the Evolution mechanical dilator sheath.Methods and resultsDuring 13 months between June 2009 and July 2010, 41 leads in 23 patients were removed. All of the extracted leads were >12 months old, and indications for extraction were based on the recommendations of the Heart Rhythm Society. The leads were removed by using the Evolution mechanical dilator sheath (Cook Medical) with the rotational cutting force only, without laser or radiofrequency energy. Indications for lead removal included cardiac device infection in 7 (30.4%) cases, lead malfunction in the 15 (65.2%) cases, and lead displacement in the remaining 1 case (4.4%). In 14 (60.9%) cases, the extracted device was a pacemaker, and implantable cardioverter defibrillators (ICD) in 9 (39.1%) of them. Among 41 leads, 25 (60.9%) were right ventricular, 14 (34%) were atrial, and 2 (4.8%) were coronary sinus electrode. The median time from the preceding procedure was 74 months (25–180 months). Complete procedural success with Evolution system alone was achieved in 19 (82%) patients (35 leads). Four leads were completely removed with snaring and in two leads, partial success was achieved with a remaining ventricular tip smaller than 1.5 cm. Clinical success was 100%, and all of the patients discharged uneventfully without a major complication.ConclusionsOur experience confirms that the mechanical technique with Evolution system is an effective first-line method for chronically implanted pacemaker/ICD leads. Continued investigation is required to evaluate success and complication rates in comparison with other techniques.
1 July 2011 in Turk Kardiyoloji Dernegi Arsivi-Archives of the Turkish Society of Cardiology
We evaluated the effect of a nationwide media campaign on hypertension awareness in the population, which was implemented with the aim of spreading key messages related to optimal blood pressure levels and encouraging blood pressure measurements. A nationwide project called "12/8 Awareness Campaign" was implemented between October 2005 and January 2006 using all available mass and outdoor media aiming to improve the knowledge of people on normal blood pressure values and to encourage regular blood pressure measurements. Four survey questions to inquire the level of awareness related to optimal blood pressure levels, hypertension, and hypertension-related disease conditions were directed via face-to-face interviews to two separate samples representing the general Turkish population before (n=1716) and after (n=1725) the campaign, respectively. The answers of the pre- and post-campaign individuals were compared. After the campaign, the percentage of participants who did not know their blood pressure levels decreased from 54.8% to 47.8%, the percentage of those who checked their blood pressure within the past two months increased from 34.3% to 39.6%, and the percentage of those who were aware of the optimal blood pressure levels rose from 51.8% to 58.6% (p<0.001). The campaign contributed significantly to the awareness of hypertension in general population, which is highly encouraging for future efforts for early detection of hypertension and prevention of related morbidity and mortality.
24 May 2007 in Catheterization and Cardiovascular Interventions
1 January 2013 in Turk Kardiyoloji Dernegi Arsivi-Archives of the Turkish Society of Cardiology