1 August 2012 in Construction and Building Materials
CBCristina Maria Belfiore
+2
1 February 2005 in Construction and Building Materials
1 October 2013 in Construction and Building Materials
30 November 2017 in Mechanics of Advanced Materials and Structures
In this paper, the results of Finite Element Analysis on concrete specimens reinforced by plant fiber and undergone to double punch tests are presented. In finite element analysis, the constitutive law of the material was calibrated by referring to tensile strength obtained by the Chen formulation and fractural energy derived by the double punch test. The analysis was carried out accounting different volume content of natural fibers derived from a very common plant of Sicily (Agave), to ensure the repeatability of the test. Then, the failure load can be determined by finite element analysis and compared with the experimental one. A good accordance between numerical and experimental data permits us to support the use of the double punch test as a more attractive testing method for the evaluation of the mechanical proprieties of the materials. Double punch test, in fact, is much simpler to perform than the split cylinder test method.
8 November 2013 in Applied Mechanics and Materials
In the past two decades, CFRP had been used to strengthen and repair r.c. structures and recently it is also employed to strengthen historical or monumental buildings constituted by masonry structure. However, premature failure due to debonding of the FRP is one of the important issues still to be resolved. Numerous word wide research studies have dealt with the debonding problem in r.c. structures but only a few works were carried out in the masonry structures area. So, the study of the global behaviour of the reinforced masonry element seems to be very useful, both for a congruous design and to verify the strengthening strategy. To this aim, this paper summarizes the debonding phenomena between C-FRP strip and natural calcareous rock brick, employed in our buildings, by means of a testing investigation. Two different kinds of anchorage were designed and employed for the tested samples: standard and reinforced anchorage. The experimental tests carried out on the specimens permits us to compare the effective bond length, with the one obtained by International rules and especially with the Italian CNR-DT200/2004 formulation and to say that the effective bond length dictates by the rules undervalues the experimental data. The data obtained permit us also to know the shear-slip delamination curve useful for the numerical investigation, as well as both the failure mode and the "II mode" fracture energy.
1 January 2014 in APCBEE Procedia
This paper presents the results obtained by an experimental program carried out to evaluate the influence of externally bonded FRP composites on the out of plane behavior of masonry. To this aim two groups of samples were tested for static out-of-plane loads under different vertical load applying orthogonally to the mortar beds. Three panels Carbon fiber- Reinforced Masonry (CRM) were reinforced by one layer of carbon fiber-reinforcing system attached to the tension side of the wall, while the remaining unreinforced three (URM) were used as referring samples. The failure loads, collapse mode, mid-span deflection and fiber-debonding were measured. Based on the data obtained from the experimental program, it appears that the out-of-plane CFRP reinforcement tends to deeply decrease the out-of plane deflection, change the collapse mechanism, and increase enormously its out of plane resistance up to seven times respect to the URM panel