Kenneth Tran

Kenneth Tran

Auto-generated profile, based on publicly available information

Kenneth Tran

Division of Vascular and Endovascular Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in JVS-Vascular Science
Verified
Journal Article
Open access
KTKenneth Tran
Kenneth Tran
WYWeiguang Yang
Weiguang Yang
AMAlison Marsden
Alison Marsden
JLJason T. Lee
Jason T. Lee
This study aimed to develop an accessible patient-specific computational flow modelling pipeline for evaluating the hemodynamic performance of fenestrated endovascular aneurysm repair (fEVAR), with the hypothesis that computational flow modelling can detect aortic branch hemodynamic changes associated with fEVAR graft implantation. Patients who underwent fEVAR for juxtarenal aortic aneurysms with the Cook ZFEN were retrospectively selected. Using open-source SimVascular software, preoperative and postoperative visceral aortic anatomy was manually segmented from computed tomography angiograms. Three-dimensional geometric models were then discretized into tetrahedral finite element meshes. Patient-specific pulsatile in-flow conditions were derived from known supraceliac aortic flow waveforms and adjusted for patient body surface area, average resting heart rate, and blood pressure. Outlet boundary conditions consisted of three-element Windkessel models approximated from physiologic flow splits. Rigid wall flow simulations were then performed on preoperative and postoperative models with the same inflow and outflow conditions. We used SimVascular’s incompressible Navier-Stokes solver to perform blood flow simulations on a cluster using 72 cores. Preoperative and postoperative flow simulations were performed for 10 patients undergoing fEVAR with a total of 30 target vessels (20 renal stents, 10 mesenteric scallops). Postoperative models required a higher mean number of mesh elements to reach mesh convergence (3.2 ± 1.8 × 106 vs 2.6 ± 1.1 × 106; P = .005) with a longer mean computational time (10.3 ± 6.3 hours vs 7.8 ± 3.5 hours; P = .04) compared with preoperative models. fEVAR was associated with small but statistically significant increases in mean peak proximal aortic arterial pressure (140.3 ± 11.0 mm Hg vs 136.9 ± 8.7 mm Hg; P = .02) and peak renal artery pressure (131.6 ± 14.8 mm Hg vs 128.9 ± 11.8 mm Hg; P = .04) compared with preoperative simulations. No differences were observed in peak pressure in the celiac, superior mesenteric, or distal aortic arteries (P = .17-.96). When measuring blood flow, the only observed difference was an increase in peak renal flow rate after fEVAR (17.5 ± 3.8 mL/s vs 16.9 ± 3.5 mL/s;P =.04). fEVAR was not associated with changes in the mean pressure or the mean flow rate in the celiac, superior mesenteric, or renal arteries (P = .06-.98). Stenting of the renal arteries did not induce significant changes time-averaged wall shear stress in the proximal renal artery (23.4 ± 8.1 dynes/cm2 vs 23.2 ± 8.4 dynes/cm2; P = .98) or distal renal artery (32.7 ± 13.9 dynes/cm2 vs 29.6 ± 11.8 dynes/cm2; P = .23). In addition, computational visualization of crosssectional velocity profiles revealed low flow disturbances associated with protrusion of renal graft fabric into the aortic lumen. In a pilot study involving a selective cohort of patients who underwent uncomplicated fEVAR, patient-specific flow modelling was a feasible method for assessing the hemodynamic performance of various two-vessel fenestrated device configurations and revealed subtle differences in computationally derived peak branch pressure and blood flow rates. Structural changes in aortic flow geometry after fEVAR do not seem to affect computationally estimated renovisceral branch perfusion or wall shear stress adversely. Additional studies with invasive angiography or phase contrast magnetic resonance imaging are required to clinically validate these findings.

1 August 2021 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
KTKenneth Tran
Kenneth Tran
GSGa-Young Suh
Ga-Young Suh
JMJustine Mougin
Justine Mougin
SHStephan Haulon
Stephan Haulon
CCChristopher Cheng
Christopher Cheng

1 January 2021 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
KTKenneth Tran
Kenneth Tran
CDCeline Deslarzes-Dubuis
Celine Deslarzes-Dubuis
JLJason T. Lee
Jason T. Lee

21 April 2022 in JVS-Vascular Science
Verified
Journal Article
Open access
KTKenneth Tran
Kenneth Tran
KFK. Brennan Feliciano
K. Brennan Feliciano
WYWeiguang Yang
Weiguang Yang
ESErica L. Schwarz
Erica L. Schwarz
AMAlison L. Marsden
Alison L. Marsden
JLJason T. Lee
Jason T. Lee
The durability of fenestrated endovascular aneurysm repair (fEVAR) has been threatened by thrombotic complications. In the present study, we used patient-specific computational fluid dynamic (CFD) simulation to investigate the effect of the endograft diameter on hemodynamics after fEVAR and explore the hypothesis that diameter-dependent alterations in aortic hemodynamics can predict for thrombotic events. A single-institutional retrospective study was performed of patients who had undergone fEVAR for juxtarenal aortic aneurysms. The patients were stratified into large diameter (34-36 mm) and small diameter (24-26 mm) endograft groups. Patient-specific CFD simulations were performed using three-dimensional paravisceral aortic models created from computed tomographic images with allometrically scaled boundary conditions. Aortic time-averaged wall shear stress (TAWSS) and residence time (RT) were computed and correlated with future thrombotic complications (eg, renal stent occlusion, development of significant intraluminal graft thrombus). A total of 36 patients (14 with a small endograft and 22 with a large endograft) were included in the present study. The patients treated with large endografts had experienced a higher incidence of thrombotic complications compared with small endografts (45.5% vs 7.1%; P = .016). Large endografts were associated with a lower postoperative aortic TAWSS (1.45 ± 0.76 dynes/cm2 vs 3.16 ± 1.24 dynes/cm2; P < .001) and longer aortic RT (0.78 ± 0.30 second vs 0.34 ± 0.08 second; P < .001). In the large endograft group, a reduction >0.39 dynes/cm2 in aortic TAWSS demonstrated discriminatory power for thrombotic complications (area under the receiver operating characteristic curve, 0.77). An increased aortic RT of ≥0.05 second had similar accuracy for predicting thrombotic complications (area under the receiver operating characteristic curve, 0.78). The odds of thrombotic complications were significantly higher if patients had met the hemodynamic threshold changes in aortic TAWSS (odds ratio, 7.0; 95% confidence interval, 1.1-45.9) and RT (odds ratio, 8.0; 95% confidence interval, 1.13-56.8). Patient-specific CFD simulation of fEVAR in juxtarenal aortic aneurysms demonstrated significant endograft diameter-dependent differences in aortic hemodynamics. A postoperative reduction in TAWSS and an increased RT correlated with future thrombotic events after large-diameter endograft implantation. Patient-specific simulation of hemodynamics provides a novel method for thrombotic risk stratification after fEVAR.

23 November 2023 in JVS-Vascular Science
Verified
Journal Article
Open access
KTKenneth Tran
Kenneth Tran
CDCeline Deslarzes-Dubuis
Celine Deslarzes-Dubuis
SDSebastien DeGlise
Sebastien DeGlise
AKAdrien Kaladji
Adrien Kaladji
WYWeiguang Yang
Weiguang Yang
JLJason T. Lee
Jason T. Lee
Endovascular aneurysm repair with four-vessel fenestrated endovascular aneurysm repair (fEVAR) or branched endovascular aneurysm repair (bEVAR) currently represent the forefront of minimally invasive complex aortic aneurysm repair. This study sought to use patient-specific computational flow simulation (CFS) to assess differences in postoperative hemodynamic effects associated with fEVAR vs bEVAR. Patients from two institutions who underwent four-vessel fEVAR with the Cook Zenith Fenestrated platform and bEVAR with the Jotec E-xtra Design platform were retrospectively selected. Patients in both cohorts were treated for paravisceral and extent II, II, and V thoracoabdominal aortic aneurysms. Three-dimensional finite element volume meshes were created from preoperative and postoperative computed tomography scans. Boundary conditions were adjusted for body surface area, heart rate, and blood pressure. Pulsatile flow simulations were performed with equivalent boundary conditions between preoperative and postoperative states. Postoperative changes in hemodynamic parameters were compared between the fEVAR and bEVAR groups. Patient-specific CFS was performed on 20 patients (10 bEVAR, 10 fEVAR) with a total of 80 target vessels (40 renal, 20 celiac, 20 superior mesenteric artery stents). bEVAR was associated with a decrease in renal artery peak flow rate (−5.2% vs +2.0%; P < .0001) and peak pressure (−3.4 vs +0.1%; P < .0001) compared with fEVAR. Almost all renal arteries treated with bEVAR had a reduction in renal artery perfusion (n = 19 [95%]), compared with 35% (n = 7) treated with fEVAR. There were no significant differences in celiac or superior mesenteric artery perfusion metrics (P = .10-.27) between groups. Time-averaged wall shear stress in the paravisceral aorta and branches also varied significantly depending on endograft configuration, with bEVAR associated with large postoperative increases in renal artery (+47.5 vs +13.5%; P = .002) and aortic time-averaged wall shear stress (+200.1% vs −31.3%; P = .001) compared with fEVAR. Streamline analysis revealed areas of hemodynamic abnormalities associated with branched renal grafts which adopt a U-shaped geometry, which may explain the observed differences in postoperative changes in renal perfusion between bEVAR and fEVAR. bEVAR may be associated with subtle decreases in renal perfusion and a large increase in aortic wall shear stress compared with fEVAR. CFS is a novel tool for quantifying and visualizing the unique patient-specific hemodynamic effect of different complex EVAR strategies. This study used patient-specific CFS to compare postoperative hemodynamic effects of four-vessel fenestrated endovascular aneurysm repair (fEVAR) and branched endovascular aneurysm repair (bEVAR) in patients with complex aortic aneurysms. The findings indicate that bEVAR may result in subtle reductions in renal artery perfusion and a significant increase in aortic wall shear stress compared with fEVAR. These differences are clinically relevant, providing insights for clinicians choosing between these approaches. Understanding the patient-specific hemodynamic effects of complex EVAR strategies, as revealed by CFS, can aid in future personalized treatment decisions, and potentially reduce postoperative complications in aortic aneurysm repair.

1 October 2021 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
JSJordan R. Stern
Jordan R. Stern
KTKenneth Tran
Kenneth Tran
MLMing Li
Ming Li
JLJason T. Lee
Jason T. Lee