In this paper the possibility of using a version of the Cúk converter in telecommunication equipment and telephone lines that require special power needs is put under analysis. The classical Cúk converter is introduced and analyzed. The mathematical equations for this DC-DC converter are deducted and the circuit is successfully simulated in PSpice after choosing correct values for the components. The self-lift Cúk converter is also introduced and modeled in the same manner and its improvements are emphasized from our point of view. Using the results obtained from simulation of the circuits the advantages of the second one are illustrated by comparison.
Cell culture assays have become a routine testing method in the medical and pharmaceutical research. Real-time monitoring of cells on a substrate using electrical impedance is a convenient and non-invasive method of analysis. Cell proliferation and apoptosis can be quantified and characterized by electrical impedance in a time-dependent manner. Unfortunately monitoring several cell cultures at the same time is challenging because of the prohibitive costs of impedance analysis equipment or rather slow response if multiplexing the front-end of an impedance analyzer. We propose a low cost high performance impedance analyzer based on a two channel delta-sigma 16-bit ADC. The device can handle frequencies between 30 Hz and 10 kHz with input impedances ranging: 100mOhms - 10Mohms. The Automatic Level Control (ALC) algorithm allows for steady non-invasive voltage levels on the measured impedance independent of measuring frequency and impedance value. The device prototype performance is compared to commercial analyzers used for monitoring cell growth and related cell based, e.g. biosensing applications. Low production cost and robustness to component tolerances owed to special digital processing inside the Digital Signal Controller (DSC) make this device very suitable to mass production, the first step in becoming a readily available tool.
The fundamental topologies like buck and boost are commonly used in low-cost PV systems combined with simple maximum power point tracking (MPPT) algorithms like the perturb-and-observe (P&O) and incremental conductance (INC). This paper presents the influence of the operating modes (Continuous/Discontinuous Current Mode) of converter over the P&O and INC algorithms. A typical architecture that avoids the topology-induced effects is presented and his performance is evaluated in a low-cost PV charger controlled by an 8-bit microcontroller.