Xiaoqi Li

Xiaoqi Li

Auto-generated profile, based on publicly available information

Xiaoqi Li

Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2012 in Medical Physics
Verified
Journal Article
Closed access
PDF file
LXLei Xi
Lei Xi
XLXiaoqi Li
Xiaoqi Li
LYLei Yao
Lei Yao
SGStephen Grobmyer
Stephen Grobmyer
HJHuabei Jiang
Huabei Jiang

18 August 2015 in Medical Physics
Verified
Journal Article
Closed access
PDF file
XLXiaoqi Li
Xiaoqi Li
CHCoy D Heldermon
Coy D Heldermon
LYLei Yao
Lei Yao
LXLei Xi
Lei Xi
HJHuabei Jiang
Huabei Jiang

21 July 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
XLXiaoqi Li
Xiaoqi Li
LXLei Xi
Lei Xi
RJRuixin Jiang
Ruixin Jiang
LYLei Yao
Lei Yao
HJHuabei Jiang
Huabei Jiang
We designed, fabricated and tested a novel imaging system that fuses diffuse optical tomography (DOT) and photoacoustic tomography (PAT) in a single platform. This platform takes advantages of both DOT and PAT, and can potentially provide dual-modality two dimensional functional and cellular images of the breast quantitatively. Here we describe this integrated platform along with initial tissue phantom validations.

22 October 2012 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
LXLei Xi
Lei Xi
XLXiaoqi Li
Xiaoqi Li
HJHuabei Jiang
Huabei Jiang
The performance of photoacoustic imaging (PAI) is critically dependent on the sensitivity and bandwidth of the transducer. Here, we report the design and fabrication of a polyvinylidene fluoride ultrasonic transducer with variable-thickness layers that demonstrates significantly improved sensitivity and bandwidth. We show that the multilayered transducer provides more than 2-fold increase in sensitivity and more than 65% improvement in bandwidth compared with the conventional single-layer transducer. Photoacoustic imaging of mouse brain with the intact skull and scalp is conducted to demonstrate the power of the multilayered transducer for resolving brain structure in an in vivo setting.

23 January 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
XLXiaoqi Li
Xiaoqi Li
HJHuabei Jiang
Huabei Jiang
We present a study through extensive simulation that considers the impact of inhomogeneous optical scattering coefficient distribution on recovery of optical absorption coefficient maps using tomographic photoacoustic data collected from media mimicking breast tissue. We found that while the impact of scattering heterogeneities/targets is modest on photoacoustic recovery of optical absorption coefficients, the impact of scattering contrast caused by adipose tissue, a layer of normal tissue along the boundary of the breast, is dramatic on reconstruction of optical absorption coefficients using photoacoustic data-up to 25.8% relative error in recovering the absorption coefficient is estimated in such cases. To overcome this problem, we propose a new method to enhance photoacoustic recovery of the optical absorption coefficient in heterogeneous media by considering inhomogeneous scattering coefficient distribution provided by diffuse optical tomography (DOT). Results from extensive simulations show that photoacoustic recovery of absorption coefficient maps can be improved considerably with a priori scattering information from DOT.

1 August 2019
Verified
Conference Paper
Closed access
XLXiaoqi Li
Xiaoqi Li
Yanbo WangYanbo Wang
Yanbo Wang
ZYZelin Yang
Zelin Yang
HZHaiping Zhou
Haiping Zhou
End-effector force of the robotic manipulator plays an important role in force control. Generally, conventional end-effector force measurement approaches need additional sensors, e.g., the force/torque (F/T) sensor and the joint torque sensor, which raise the cost and introduce complexity into manipulators’ mechanical and electrical design. Therefore, we propose an approach to estimate the end-effector contact force of a manipulator utilizing the motor current measurement without any additional sensors. By building the dynamics model of the manipulator with external wrench, the proposed approach utilizes the friction torque model of the joints to improve the precise of the wrench estimation. Additionally, In order to identify the parameters of motors and the friction torque model, a parameter identification method based on non-linear least squares regression is introduced. The experiments are implemented on the robot IRIC-I which is developed in our lab. Experimental results indicate that the end-effector force can be reliably estimated without any extra sensors, and show the potential of utilizing the estimated end-effector force in force control of the robotic manipulator.