Fauzan Khairi Che Harun

Fauzan Khairi Che Harun

Auto-generated profile, based on publicly available information

Fauzan Khairi Che Harun

Universiti Teknologi Malaysia

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2023 in Journal of Technology and Science Education
Verified
Journal Article
Open access
PDF file
LALintang Rizkyta Ananda
Lintang Rizkyta Ananda
Yuli RahmawatiYuli Rahmawati
Yuli Rahmawati
FKFauzan Khairi
Fauzan Khairi
This project seeks to foster students' critical thinking abilities through the incorporation of Design Thinking with STEAM-PjBL in a chemistry redox process. 41 grade 10 students from a high school in Rangkasbitung, Banten, Indonesia participated in this study. Learning was facilitated by using a variety of online platforms, including Edmodo, Google Jamboard, and Zoom Meetings. Interviews, observations, journal reflection procedures, and researcher notes were used to gather qualitative data. The five steps of Design Thinking: empathize, define, ideate, prototype, and test, were used to facilitate learning (Plattner, 2010). Critical thinking skills were assessed through the indicators of Framing The Problem, Solution Finding, Self-Regulation, and Reflection, developed by Ucson & Rizona (2018). Based on the categories of Information Search, Creative Interpretation and Reasoning, Reflection, and Self-Regulation, the results demonstrate the development of students' critical thinking abilities to the advanced level. Design Thinking provides a way to more easily and actively create project-based solutions in solving contextual problems related to redox reaction of water pollution in the Ciujung River due to the use of detergent waste. Understanding the relationship of chemical concepts to daily life challenges the application of this approach. To challenge students' learning and help them acquire 21st-century abilities, STEAM-PjBL may be integrated with Design Thinking.

1 February 2012
Verified
Conference Paper
Closed access
NZNor Saradatul Akmar Zulkifli
Nor Saradatul Akmar Zulkifli
FHF.K. Che Harun
F.K. Che Harun
NAN.S. Azahar
N.S. Azahar
Heart Rate Monitors (HRMs) have become widely used since the last two decades. It used as training aid for various types of sports. And the development of new HRMs has evolved rapidly. Thus, in order to determine the exercise intensity of training session or race, HRMs are mainly used. Compared to the other indication of exercise intensity, Heart rate is easy to monitor, compatible to use in most situation and relatively cheap. Thus, it is most beneficial if wireless sensor network can be implementing into the system. Other than monitored their condition by themselves, this system may allowed a number of athletes being monitored simultaneously. Arduino-Nano board was used to interface with nRF24AP1 and XBee. The wireless sensor network consists of a microcontroller on Arduino-Nano board, nRF24AP1 and the XBee wireless communication module which is based on the IEEE 802.15.4. This system will involve peer to peer communication of ANT+ and mesh networking among the XBee.

11 June 2009 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FHF.K. Che Harun
F.K. Che Harun
JTJ.E. Taylor
J.E. Taylor
James CovingtonJames Covington
James Covington
JGJulian William Gardner
Julian William Gardner

16 April 2013 in Discover Nano
Verified
Journal Article
Open access
PDF file
MKMohammad Javad Kiani
Mohammad Javad Kiani
MAMohammad Taghi Ahmadi
Mohammad Taghi Ahmadi
HAHediyeh Karimi Feiz Abadi
Hediyeh Karimi Feiz Abadi
MRMeisam Rahmani
Meisam Rahmani
AHAmin Hashim
Amin Hashim
FHFauzan Khairi Che Harun
Fauzan Khairi Che Harun
Graphene has attracted great interest because of unique properties such as high sensitivity, high mobility, and biocompatibility. It is also known as a superior candidate for pH sensing. Graphene-based ion-sensitive field-effect transistor (ISFET) is currently getting much attention as a novel material with organic nature and ionic liquid gate that is intrinsically sensitive to pH changes. pH is an important factor in enzyme stabilities which can affect the enzymatic reaction and broaden the number of enzyme applications. More accurate and consistent results of enzymes must be optimized to realize their full potential as catalysts accordingly. In this paper, a monolayer graphene-based ISFET pH sensor is studied by simulating its electrical measurement of buffer solutions for different pH values. Electrical detection model of each pH value is suggested by conductance modelling of monolayer graphene. Hydrogen ion (H+) concentration as a function of carrier concentration is proposed, and the control parameter (Ƥ) is defined based on the electro-active ions absorbed by the surface of the graphene with different pH values. Finally, the proposed new analytical model is compared with experimental data and shows good overall agreement.

1 September 2009 in Procedia Chemistry
Verified
Journal Article
Open access
FHF.K. Che Harun
F.K. Che Harun
James CovingtonJames Covington
James Covington
JGJulian William Gardner
Julian William Gardner
Here we report on the implementation of a new portable electronic nose instrument, inspired by the human olfactory system. Our ‘Portable e-Mucosa’ (PeM) utilizes three large sensor arrays consisting of 200 chemoresistive sensors per array, combined with two columns coated with differently retentive layers. This combination provides spatio-temporal information, mimicking the biological ‘nasal chromatograph’ effect[1]. These have been integrated with control electronics, a pre-concentrator, temperature control and a sample delivery system to produce a fully functional electronic nose (e-nose) instrument. Data from this device, when used with a pattern recognition method that utilizes temporal information and the large data set, we believe improves the discrimination power of this instrument over conventional e-noses.

1 June 2012 in IET Nanobiotechnology
Verified
Journal Article
Closed access
FHF.K. Che Harun
F.K. Che Harun
James CovingtonJames Covington
James Covington
JGJulian William Gardner
Julian William Gardner
In this study the authors report on the development of a new type of electronic nose (e-nose) instrument, which the authors refer to as the Portable electronic Mucosa (PeM) as a continuation of previous research. It is designed to mimic the human nose by taking significant biological features and replicating them electronically. The term electronic mucosa or simply e-mucosa was used because our e-nose emulates the nasal chromatographic effect discovered in the olfactory epithelium, located within the upper turbinate. The e-mucosa generates spatio-temporal information that the authors believe could lead to improved odour discrimination. The PeM comprises three large sensor arrays each containing a total of 576 sensors, with 24 different coatings, to increase the odour selectivity. The nasal chromatographic effect provides temporal information in the human olfactory system, and is mimicked here using two-coated retentive channels. These channels are coated with polar and non-polar compounds to enhance the selectivity of the instrument. Thus, for an unknown sample, the authors have both the spatial information (as with a traditional e-nose) and the temporal information. The authors believe that this PeM may offer a way forward in developing a new range of low-cost e-noses with superior odour specificity.