Sandhya Karunakaran Yesodha

Sandhya Karunakaran Yesodha

Auto-generated profile, based on publicly available information

Sandhya Karunakaran Yesodha

Department of Chemistry, Indian Institute of Space Science and Technology Valiyamala, Thiruvananthapuram 695-547, Kerala, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2018 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
RAR. Aswathi
R. Aswathi
KSK. Y. Sandhya
K. Y. Sandhya
A solvent exfoliated molybdenum disulphide (MoS2) has been exploited for the electrochemical (EC) sensing of mercury(ii) ions (Hg2+) with excellent selectivity and a detection limit (LOD) of 0.000001 nM,i.e.in parts per quadrillion (0.2 ppq) levels.

9 December 2020 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
SSS. Saisree
S. Saisree
RAR. Aswathi
R. Aswathi
JNJ. S. Arya Nair
J. S. Arya Nair
KSK. Y. Sandhya
K. Y. Sandhya
In the present work, the sensing capability of nitrogen-doped graphene quantum dots (N-GQDs) was explored for the first time toward hazardous heavy metal ions and they were found to be able to selectively detect cadmium ions (Cd(II)). Cd(II) is one of the hazardous heavy metal ions on the World Health Organization's list of 10 chemicals of major public health concern. The wide use of Cd(II) in industrial applications and its acute and chronic effects on living beings make the sensing of Cd(II) critical. The aromatic N-GQDs, synthesized here through a hydrothermal route using the single precursor polyaniline exhibited a 25- and 6-fold increase in the current response compared to that of a glassy carbon electrode (GCE) and GQD/GCE, respectively. It showed an excellent and exemplary selectivity toward Cd(II), with almost a nil current response for other interfering metal ions. The LOD value of 1.0 × 10−5 ppb, i.e., in parts per trillion, by N-GQDs is the lowest value ever reported, which was 3–4 orders of magnitude lower than the previously reported values. The LOD was extended to the ultra-high sensitivity level of 1 × 10−7 ppb, i.e., in parts per quadrillion, using a pre-reduction step. The LDR (0.001–112 000 ppb) and LOD values satisfactorily met the sensitivity requirement for detecting Cd(II) within the safe limit specified by the U.S. Environmental Protection Agency (EPA) of ≤5 ppb. The sensing performance of N-GQD/GCE was tested against real environmental samples spiked with Cd(II), such as groundwater, seawater, and wastewater, and was found to perform efficiently.

10 January 2023 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
SSSaisree S
Saisree S
ASArya Nair J. S
Arya Nair J. S
SYSandhya Karunakaran Yesodha
Sandhya Karunakaran Yesodha

9 March 2022 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
SSSaisree S.
Saisree S.
ASArya Nair J. S.
Arya Nair J. S.
SYSandhya K. Y.
Sandhya K. Y.
CuNC@N-GQDs are synthesised from CuSO4, GSH and N-GQDs and utilised for the simultaneous electrochemical sensing of DA, SER and NIC.

18 May 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
AJArya Nair J.S
Arya Nair J.S
SSSaisree. S
Saisree. S
KSK. Y. Sandhya
K. Y. Sandhya
Herein, a graphene-nano-molybdenum disulphide (pGr-MoS2), synthesized from pulverized graphite and using precursors of MoS2, was investigated for the electrochemical sensing of dihydroxy benzene isomers (DHBI): hydroquinone (HQ), catechol (CA), and resorcinol (RE). Interestingly, the material could sense the three isomers simultaneously, with well-defined peaks and an adequate potential difference between each peak. The detection limits (3σ method) of HQ, CA, and RE on the glassy carbon electrode (GCE) modified with pGr-MoS2 are 10−13, 10−12, and 10−8 M (i.e., 0.1 pM, 1 pM, and 10 nM), respectively, and are the lowest reported so far for the isomers. The pGr-MoS2/GCE exhibited selectivity towards DHBI, in the presence of other toxic contaminants and metal ions such as phenol, dinitrophenol, trinitrophenol, urea and glucose, Hg(II), Ca(II), Ni(II), Zn(II), Cu(II), Na(I) and K(I). A possible mechanism for this superior selectivity of pGr-MoS2 towards DHBI is discussed based on the structural properties of pGr-MoS2 with evidence. Further, the pGr-MoS2 sensor exhibited reproducibility (with six different electrodes), stability (≥90 days), and repeatability properties. The sensing performance was successfully demonstrated in real water samples such as ground-, tap-, and river- water spiked with HQ, CA, and RE.

4 August 2016 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
MAMohamed Mukthar Ali
Mohamed Mukthar Ali
KSKarunakaran Nair Yesodha Sandhya
Karunakaran Nair Yesodha Sandhya
TiO2–MoS2composites are prepared from a novel molybdenum–sulphur cluster, (NH4)2Mo3S13·2H2O, and TiOP. A composite with 0.7% loaded MoS2showed enhanced visible light photodegradation properties.