Xiuting Liang

Xiuting Liang

Auto-generated profile, based on publicly available information

Xiuting Liang

Department of Respiratory and Critical Care Medicine, the First Medical Centre, Chinese PLA General Hospital, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JLJiayu Liu
Jiayu Liu
XLXiuting Liang
Xiuting Liang
DFDandong Fang
Dandong Fang
JZJiqi Zheng
Jiqi Zheng
CYchengliang yin
chengliang yin
JZJianning Zhang
Jianning Zhang
Background: ChatGPT (OpenAI) has shown great potential in clinical diagnosis and could become an excellent auxiliary tool in clinical practice. This study investigates and evaluates ChatGPT in diagnostic capabilities by comparing the performance of GPT-3.5 and GPT-4.0 across model iterations. Objective: This study aims to evaluate the precise diagnostic ability of GPT-3.5 and GPT-4.0 for colon cancer and its potential as an auxiliary diagnostic tool for surgeons and compare the diagnostic accuracy rates between GTP-3.5 and GPT-4.0. We precisely assess the accuracy of primary and secondary diagnoses and analyze the causes of misdiagnoses in GPT-3.5 and GPT-4.0 according to 7 categories: patient histories, symptoms, physical signs, laboratory examinations, imaging examinations, pathological examinations, and intraoperative findings. Methods: We retrieved 316 case reports for intestinal cancer from the Chinese Medical Association Publishing House database, of which 286 cases were deemed valid after data cleansing. The cases were translated from Mandarin to English and then input into GPT-3.5 and GPT-4.0 using a simple, direct prompt to elicit primary and secondary diagnoses. We conducted a comparative study to evaluate the diagnostic accuracy of GPT-4.0 and GPT-3.5. Three senior surgeons from the General Surgery Department, specializing in Colorectal Surgery, assessed the diagnostic information at the Chinese PLA (People’s Liberation Army) General Hospital. The accuracy of primary and secondary diagnoses was scored based on predefined criteria. Additionally, we analyzed and compared the causes of misdiagnoses in both models according to 7 categories: patient histories, symptoms, physical signs, laboratory examinations, imaging examinations, pathological examinations, and intraoperative findings. Results: Out of 286 cases, GPT-4.0 and GPT-3.5 both demonstrated high diagnostic accuracy for primary diagnoses, but the accuracy rates of GPT-4.0 were significantly higher than GPT-3.5 (mean 0.972, SD 0.137 vs mean 0.855, SD 0.335; t285=5.753; P<.001). For secondary diagnoses, the accuracy rates of GPT-4.0 were also significantly higher than GPT-3.5 (mean 0.908, SD 0.159 vs mean 0.617, SD 0.349; t285=–7.727; P<.001). GPT-3.5 showed limitations in processing patient history, symptom presentation, laboratory tests, and imaging data. While GPT-4.0 improved upon GPT-3.5, it still has limitations in identifying symptoms and laboratory test data. For both primary and secondary diagnoses, there was no significant difference in accuracy related to age, gender, or system group between GPT-4.0 and GPT-3.5. Conclusions: This study demonstrates that ChatGPT, particularly GPT-4.0, possesses significant diagnostic potential, with GPT-4.0 exhibiting higher accuracy than GPT-3.5. However, GPT-4.0 still has limitations, particularly in recognizing patient symptoms and laboratory data, indicating a need for more research in real-world clinical settings to enhance its diagnostic capabilities.

29 November 2023 in JMIR Preprints
Verified
Preprint
Open access
JLJiayu Liu
Jiayu Liu
XLXiuting Liang
Xiuting Liang
DFDandong Fang
Dandong Fang
JZJiqi Zheng
Jiqi Zheng
CYchengliang yin
chengliang yin
JZJianning Zhang
Jianning Zhang
BACKGROUND ChatGPT (OpenAI) has shown great potential in clinical diagnosis and could become an excellent auxiliary tool in clinical practice. This study investigates and evaluates ChatGPT in diagnostic capabilities by comparing the performance of GPT-3.5 and GPT-4.0 across model iterations. OBJECTIVE This study aims to evaluate the precise diagnostic ability of GPT-3.5 and GPT-4.0 for colon cancer and its potential as an auxiliary diagnostic tool for surgeons and compare the diagnostic accuracy rates between GTP-3.5 and GPT-4.0. We precisely assess the accuracy of primary and secondary diagnoses and analyze the causes of misdiagnoses in GPT-3.5 and GPT-4.0 according to 7 categories: patient histories, symptoms, physical signs, laboratory examinations, imaging examinations, pathological examinations, and intraoperative findings. METHODS We retrieved 316 case reports for intestinal cancer from the Chinese Medical Association Publishing House database, of which 286 cases were deemed valid after data cleansing. The cases were translated from Mandarin to English and then input into GPT-3.5 and GPT-4.0 using a simple, direct prompt to elicit primary and secondary diagnoses. We conducted a comparative study to evaluate the diagnostic accuracy of GPT-4.0 and GPT-3.5. Three senior surgeons from the General Surgery Department, specializing in Colorectal Surgery, assessed the diagnostic information at the Chinese PLA (People’s Liberation Army) General Hospital. The accuracy of primary and secondary diagnoses was scored based on predefined criteria. Additionally, we analyzed and compared the causes of misdiagnoses in both models according to 7 categories: patient histories, symptoms, physical signs, laboratory examinations, imaging examinations, pathological examinations, and intraoperative findings. RESULTS Out of 286 cases, GPT-4.0 and GPT-3.5 both demonstrated high diagnostic accuracy for primary diagnoses, but the accuracy rates of GPT-4.0 were significantly higher than GPT-3.5 (mean 0.972, SD 0.137 vs mean 0.855, SD 0.335; t285=5.753; P<.001). For secondary diagnoses, the accuracy rates of GPT-4.0 were also significantly higher than GPT-3.5 (mean 0.908, SD 0.159 vs mean 0.617, SD 0.349; t285=–7.727; P<.001). GPT-3.5 showed limitations in processing patient history, symptom presentation, laboratory tests, and imaging data. While GPT-4.0 improved upon GPT-3.5, it still has limitations in identifying symptoms and laboratory test data. For both primary and secondary diagnoses, there was no significant difference in accuracy related to age, gender, or system group between GPT-4.0 and GPT-3.5. CONCLUSIONS This study demonstrates that ChatGPT, particularly GPT-4.0, possesses significant diagnostic potential, with GPT-4.0 exhibiting higher accuracy than GPT-3.5. However, GPT-4.0 still has limitations, particularly in recognizing patient symptoms and laboratory data, indicating a need for more research in real-world clinical settings to enhance its diagnostic capabilities.

28 March 2026 in Neurosurgical Subspecialties
Verified
Journal Article
Open access
YWYuxin Wang
Yuxin Wang
MLMeijing Liu
Meijing Liu
SSShichao Su
Shichao Su
JHJunru Hei
Junru Hei
WLWenxuan Li
Wenxuan Li
JLJiayu Liu
Jiayu Liu
Mild traumatic brain injury (mTBI) represents the majority of head injury presentations in emergency departments (EDs), yet only a minority of patients have acute intracranial lesions on computed tomography (CT). This leads to widespread use of unnecessary CT scans. Point-of-care (POC) biosensing, defined as analytical testing performed at or near the site of patient care, offers a promising solution to this dilemma by enabling rapid biomarker quantification to inform CT decision-making. This review aims to evaluate POC-compatible biosensing strategies for ultra-early mTBI triage, with emphasis on platforms, matrix effects, and benchmarking aligned with CT-based decision-making. Two key precedents support this approach: (1) the integration of S100B into Scandinavian Neurotrauma Committee guidelines, which has demonstrated the potential for safe reduction of CT scans, and (2) the regulatory clearance of glial fibrillary acidic protein (GFAP) and ubiquitin C-terminal hydrolase-L1 (UCH-L1) testing to rule out the need for head CT in adults with suspected mTBI (Glasgow Coma Scale 13–15) when serum is collected within 12 hours of injury. Accordingly, this review focuses on the most implementable use case for mTBI, namely CT triage/rule-out. It synthesizes the current biomarker landscape (S100B, GFAP, UCH-L1), analyzes POC-suitable sensing modalities, and proposes a practical validation and benchmarking framework aligned with this intended use. A critical component is interference testing and real-world sample robustness, including vulnerabilities such as hemolysis-related elevation of UCH-L1. In conclusion, the most reliable path for biosensor translation in mTBI is to anchor development and validation to the ED CT-triage use case, emphasizing decision-point robustness and resilience to real-world sample variability over pure analytical sensitivity.