Karl Johnson

Karl Johnson

Auto-generated profile, based on publicly available information

Karl Johnson

University of California

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2022 in Optics Express
Verified
Journal Article
Closed access
KJKarl Johnson
Karl Johnson
NANaif Alshamrani
Naif Alshamrani
DADhaifallah Almutairi
Dhaifallah Almutairi
AGAndrew Grieco
Andrew Grieco
CHCameron Horvath
Cameron Horvath
YFYeshaiahu Fainman
Yeshaiahu Fainman
There is little literature characterizing the temperature-dependent thermo-optic coefficient (TOC) for low pressure chemical vapor deposition (LPCVD) silicon nitride or plasma enhanced chemical vapor deposition (PECVD) silicon dioxide at temperatures above 300 K. In this study, we characterize these material TOC’s from approximately 300-460 K, yielding values of (2.51 ± 0.08) · 10−5K−1 for silicon nitride and (5.67 ± 0.53) · 10−6K−1 for silicon oxide at room temperature (300 K). We use a simplified experimental setup and apply an analytical technique to account for thermal expansion during the extraction process. We also show that the waveguide geometry and method used to determine the resonant wavelength have a substantial impact on the precision of our results, a fact which can be used to improve the precision of numerous ring resonator index sensing experiments.

13 September 2023 in Bioengineering
Verified
Journal Article
Open access
TPTristan C. Paul
Tristan C. Paul
KJKarl A. Johnson
Karl A. Johnson
GHGuy M. Hagen
Guy M. Hagen
Super-resolution structured illumination microscopy (SR-SIM) is an optical fluorescence microscopy method which is suitable for imaging a wide variety of cells and tissues in biological and biomedical research. Typically, SIM methods use high spatial frequency illumination patterns generated by laser interference. This approach provides high resolution but is limited to thin samples such as cultured cells. Using a different strategy for processing raw data and coarser illumination patterns, we imaged through a 150-micrometer-thick coronal section of a mouse brain expressing GFP in a subset of neurons. The resolution reached 144 nm, an improvement of 1.7-fold beyond conventional widefield imaging.

29 October 2020 in Journal of Lightwave Technology
Verified
Journal Article
Open access
NANaif Alshamrani
Naif Alshamrani
AGAndrew Grieco
Andrew Grieco
AFAlex Friedman
Alex Friedman
KJKarl A. Johnson
Karl A. Johnson
MKMyun-Sik Kim
Myun-Sik Kim
SFShaya Fainman
Shaya Fainman
In this work we experimentally demonstrate a fully packaged one-dimensional beam steering system that is based on a fully CMOS compatible silicon photonics platform. This configuration enables multi-wavelength operation and is suitable for short-wavelength infrared (SWIR) applications from light detection and ranging (LIDAR) to telecommunication and sensing applications. The switching fabric in this system employs a 1x9 array of add/drop ring resonators that are fed by a common waveguide through a single etch input grating. The switching fabric re-directs the resonance wavelengths at each drop waveguide to the output facet at the edge of the chip and into free space. The divergent beams that exit the waveguides along the output facet are then collimated and magnified using an array of micro-lenses (pitch = 750 μm, Diameter = 700 μm) in addition to a two lens afocal system in order to enhance the fill factor and diminish any blind zones between adjacent beams. Each one of these drop waveguides is used to address portion of the steering aperture. Combined together they enable steering across the entire aperture. Multi-wavelength operation is obtained by placing individual titanium tungsten alloy (TiW) heaters on top of each ring resonator to enable wavelength tuning.

20 July 2022 in Photonics
Verified
Journal Article
Open access
PDF file
KJKarl A. Johnson
Karl A. Johnson
DNDaniel Noble
Daniel Noble
RMRosa Machado
Rosa Machado
TPTristan C. Paul
Tristan C. Paul
GHGuy M. Hagen
Guy M. Hagen
Fluorescence microscopy provides an unparalleled tool for imaging biological samples. However, producing high-quality volumetric images quickly and without excessive complexity remains a challenge. Here, we demonstrate a four-camera structured illumination microscope (SIM) capable of simultaneously imaging multiple focal planes, allowing for the capture of 3D fluorescent images without any axial movement of the sample. This setup allows for the acquisition of many different 3D imaging modes, including 3D time lapses, high-axial-resolution 3D images, and large 3D mosaics. We imaged mitochondrial motions in live cells, neuronal structure in Drosophila larvae, and imaged up to 130 µm deep into mouse brain tissue. After SIM processing, the resolution measured using one of the four cameras improved from 357 nm to 253 nm when using a 30×/1.05 NA objective.

31 January 2023 in Optics Letters
Verified
Journal Article
Closed access
HNHani Nejadriahi
Hani Nejadriahi
PGPrabhav Gaur
Prabhav Gaur
KJKarl Johnson
Karl Johnson
SPSteve Pappert
Steve Pappert
YFYeshaiahu Fainman
Yeshaiahu Fainman
PYPaul Yu
Paul Yu
The design, fabrication, and characterization of a 16-element optical phased array (OPA) using a high index (n = 3.1) silicon-rich silicon nitride (SRN) is demonstrated. We present one-dimensional beam steering with end-fire facet antennas over a wide steering range of >115° at a fixed wavelength of 1525 nm. A beam width of 6.3° has been measured at boresight, consistent with theory. We demonstrate SRN as a viable material choice for chip-scale OPA applications due to its high thermo-optic coefficient, high optical power handling capacity [negligible two-photon absorption (TPA)], wide transparency window, and CMOS compatibility.

27 March 2025 in Optics Express
Verified
Journal Article
Closed access
VFVladimir Fedorov
Vladimir Fedorov
KJKarl Johnson
Karl Johnson
DBDmitrii Belogolovskii
Dmitrii Belogolovskii
YFYeshaiahu Fainman
Yeshaiahu Fainman
AGAndrew Grieco
Andrew Grieco
Waveguide propagation loss and coupling coefficients are key parameters that must be measured routinely following fabrication of integrated photonic chips. While multiple methods exist to measure these parameters, existing methods are either sensitive to off-chip coupling uncertainty and occupy a large footprint (cutback method) or cannot unambiguously distinguish waveguide losses from coupling coefficients (all-pass ring resonator method). In this work, we show that by performing two spectral measurements of an add-drop ring resonator, the waveguide loss and ring-waveguide coupling coefficients can be recovered and unambiguously identified. We perform uncertainty analysis and show that this method recovers waveguide loss and coupling coefficients with lower uncertainty than alternative methods in many situations. Finally, we perform several experimental demonstrations of the technique, highlighting its increased robustness to defects compared to the cutback method and its capability to measure waveguide losses and coupling coefficients on various waveguide platforms. As the add-drop ring resonator used has a relatively small footprint (roughly 200 µm x 100 µm) and unambiguous results can be obtained through measurement of individual resonances, this method represents a convenient tool for integrated photonic process development and fabrication monitoring.