Moshe Tessler

Moshe Tessler

Auto-generated profile, based on publicly available information

Moshe Tessler

Soreq Nuclear Research Center, Yavne 81800, Israel

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2018 in The European Physical Journal A
Verified
Journal Article
Closed access
PDF file
IMIsrael Mardor
Israel Mardor
OAOfer Aviv
Ofer Aviv
MAMarilena Avrigeanu
Marilena Avrigeanu
DBDan Berkovits
Dan Berkovits
ADAdi Dahan
Adi Dahan
LWLeo Weissman
Leo Weissman

1 May 2014 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SHS. Halfon
S. Halfon
AAA. Arenshtam
A. Arenshtam
DKD. Kijel
D. Kijel
MPM. Paul
M. Paul
LWL. Weissman
L. Weissman
ZYZ. Yungrais
Z. Yungrais
The free-surface Liquid-Lithium Target, recently developed at Soreq Applied Research Accelerator Facility (SARAF), was successfully used with a 1.9 MeV, 1.2 mA (2.3 kW) continuous-wave proton beam. Neutrons (∼2 × 1010 n/s having a peak energy of ∼27 keV) from the 7Li(p,n)7Be reaction were detected with a fission-chamber detector and by gold activation targets positioned in the forward direction. The setup is being used for nuclear astrophysics experiments to study neutron-induced reactions at stellar energies and to demonstrate the feasibility of accelerator-based boron neutron capture therapy.

28 March 2019 in The European Physical Journal A
Verified
Journal Article
Closed access
PDF file
MPMichael Paul
Michael Paul
MTMoshe Tessler
Moshe Tessler
MFMoshe Friedman
Moshe Friedman
SHShlomi Halfon
Shlomi Halfon
TPTala Palchan
Tala Palchan
ISIdo Silverman
Ido Silverman

1 December 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SHS. Halfon
S. Halfon
AAA. Arenshtam
A. Arenshtam
DKD. Kijel
D. Kijel
MPM. Paul
M. Paul
DBD. Berkovits
D. Berkovits
ISI. Silverman
I. Silverman
A compact liquid-lithium target (LiLiT) was built and tested with a high-power electron gun at the Soreq Nuclear Research Center. The lithium target, to be bombarded by the high-intensity proton beam of the Soreq Applied Research Accelerator Facility (SARAF), will constitute an intense source of neutrons produced by the 7Li(p,n)7Be reaction for nuclear astrophysics research and as a pilot setup for accelerator-based Boron Neutron Capture Therapy. The liquid-lithium jet target acts both as neutron-producing target and beam dump by removing the beam thermal power (>5 kW, >1 MW/cm3) with fast transport. The target was designed based on a thermal model, accompanied by a detailed calculation of the 7Li(p,n) neutron yield, energy distribution, and angular distribution. Liquid lithium is circulated through the target loop at ∼200 °C and generates a stable 1.5 mm-thick film flowing at a velocity up to 7 m/s onto a concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power areal densities of >4 kW/cm2 and volume power density of ∼2 MW/cm3 at a lithium flow of ∼4 m/s while maintaining stable temperature and vacuum conditions. The LiLiT setup is presently in online commissioning stage for high-intensity proton beam irradiation (1.91–2.5 MeV, 1–2 mA) at SARAF.

1 December 2015 in Physics Letters B
Verified
Journal Article
Open access
MTM. Tessler
M. Tessler
MPM. Paul
M. Paul
AAA. Arenshtam
A. Arenshtam
GFG. Feinberg
G. Feinberg
MFM. Friedman
M. Friedman
ZYZ. Yungrais
Z. Yungrais
A high-power Liquid-Lithium Target (LiLiT) was used for the first time for neutron production via the thick-target Li7(p,n)Be7 reaction and quantitative determination of neutron capture cross sections. Bombarded with a 1–2 mA proton beam at 1.92 MeV from the Soreq Applied Research Accelerator Facility (SARAF), the setup yields a 30-keV quasi-Maxwellian neutron spectrum with an intensity of 3–5×1010 n/s, more than one order of magnitude larger than present near-threshold Li7(p,n) neutron sources. The setup was used here to determine the 30-keV Maxwellian averaged cross section (MACS) of 94Zr and 96Zr as 28.0±0.6 mb and 12.4±0.5 mb respectively, based on activation measurements. The precision of the cross section determinations results both from the high neutron yield and from detailed simulations of the entire experimental setup. We plan to extend our experimental studies to low-abundance and radioactive targets. In addition, we show here that the setup yields intense high-energy (17.6 and 14.6 MeV) prompt capture γ rays from the Li7(p,γ)Be8 reaction with yields of ∼3×108γs−1mA−1 and ∼4×108γs−1mA−1, respectively, evidenced by the Zr90(γ,n)Zr89 photonuclear reaction

11 September 2018 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
MTM. Tessler
M. Tessler
MPM. Paul
M. Paul
SHS. Halfon
S. Halfon
BMB. S. Meyer
B. S. Meyer
RPR. Pardo
R. Pardo
RVR. Vondrasek
R. Vondrasek
The Ar36(n,γ)Ar37 (t1/2=35  d) and Ar38(n,γ)Ar39 (269 yr) reactions were studied for the first time with a quasi-Maxwellian (kT∼47  keV) neutron flux for Maxwellian average cross section (MACS) measurements at stellar energies. Gas samples were irradiated at the high-intensity Soreq applied research accelerator facility-liquid-lithium target neutron source and the Ar37/Ar36 and Ar39/Ar38 ratios in the activated samples were determined by accelerator mass spectrometry at the ATLAS facility (Argonne National Laboratory). The Ar37 activity was also measured by low-level counting at the University of Bern. Experimental MACS of Ar36 and Ar38, corrected to the standard 30 keV thermal energy, are 1.9(3) and 1.3(2) mb, respectively, differing from the theoretical and evaluated values published to date by up to an order of magnitude. The neutron-capture cross sections of Ar36,38 are relevant to the stellar nucleosynthesis of light neutron-rich nuclides; the two experimental values are shown to affect the calculated mass fraction of nuclides in the region A=36–48 during the weak s process. The new production cross sections have implications also for the use of Ar37 and Ar39 as environmental tracers in the atmosphere and hydrosphere.