Ester Reina-Torres

Ester Reina-Torres

Auto-generated profile, based on publicly available information

Ester Reina-Torres

Department of Bioengineering, Imperial College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JBJoseph van Batenburg-Sherwood
Joseph van Batenburg-Sherwood
EREster Reina-Torres
Ester Reina-Torres
JBJacques A. Bertrand
Jacques A. Bertrand
BRBarnaby Rowe
Barnaby Rowe
DODarryl R. Overby
Darryl R. Overby
Elevated intraocular pressure (IOP) is the predominant risk factor for glaucoma, and reducing IOP is the only successful strategy to prevent further glaucomatous vision loss. IOP is determined by the balance between the rates of aqueous humour secretion and outflow, and a pathological reduction in the hydraulic conductance of outflow, known as outflow facility, is responsible for IOP elevation in glaucoma. Mouse models are often used to investigate the mechanisms controlling outflow facility, but the diminutive size of the mouse eye makes measurement of outflow technically challenging. In this study, we present a new approach to measure and analyse outflow facility using iPerfusion™, which incorporates an actuated pressure reservoir, thermal flow sensor, differential pressure measurement and an automated computerised interface. In enucleated eyes from C57BL/6J mice, the flow-pressure relationship is highly non-linear and is well represented by an empirical power law model that describes the pressure dependence of outflow facility. At zero pressure, the measured flow is indistinguishable from zero, confirming the absence of any significant pressure independent flow in enucleated eyes. Comparison with the commonly used 2-parameter linear outflow model reveals that inappropriate application of a linear fit to a non-linear flow-pressure relationship introduces considerable errors in the estimation of outflow facility and leads to the false impression of pressure-independent outflow. Data from a population of enucleated eyes from C57BL/6J mice show that outflow facility is best described by a lognormal distribution, with 6-fold variability between individuals, but with relatively tight correlation of facility between fellow eyes. iPerfusion represents a platform technology to accurately and robustly characterise the flow-pressure relationship in enucleated mouse eyes for the purpose of glaucoma research and with minor modifications, may be applied in vivo to mice, as well as to eyes from other species or different biofluidic systems.

28 November 2020 in Progress in Retinal and Eye Research
Verified
Journal Article
Closed access
EREster Reina-Torres
Ester Reina-Torres
MIMichael L. De Ieso
Michael L. De Ieso
LPLouis R. Pasquale
Louis R. Pasquale
MMMichael Madekurozwa
Michael Madekurozwa
JBJoseph van Batenburg-Sherwood
Joseph van Batenburg-Sherwood
WSW. Daniel Stamer
W. Daniel Stamer

21 February 2017 in Advanced Materials
Verified
Journal Article
Open access
PDF file
Rona  ChandrawatiRona Chandrawati
Rona Chandrawati
JCJason Y. H. Chang
Jason Y. H. Chang
EREster Reina‐Torres
Ester Reina‐Torres
CJColine Jumeaux
Coline Jumeaux
JBJoseph van Batenburg-Sherwood
Joseph van Batenburg-Sherwood
MSMolly M. Stevens
Molly M. Stevens
Nitric oxide (NO) is able to lower intraocular pressure (IOP); however, its therapeutic effects on outflow physiology are location- and dose-dependent. A NO delivery platform that directly targets the resistance-generating region of the conventional outflow pathway and locally liberates a controlled dose of NO is reported. An increase in outflow facility (decrease in IOP) is demonstrated in a mouse model.

1 February 2017 in Human Molecular Genetics
Verified
Journal Article
Open access
PDF file
JOJeffrey O'Callaghan
Jeffrey O'Callaghan
DCDarragh. E. Crosbie
Darragh. E. Crosbie
PCPaul. S. Cassidy
Paul. S. Cassidy
JBJoseph van Batenburg-Sherwood
Joseph van Batenburg-Sherwood
CFCassandra Flügel-Koch
Cassandra Flügel-Koch
PHPete Humphries
Pete Humphries
Intraocular pressure (IOP) is maintained as a result of the balance between production of aqueous humour (AH) by the ciliary processes and hydrodynamic resistance to its outflow through the conventional outflow pathway comprising the trabecular meshwork (TM) and Schlemm’s canal (SC). Elevated IOP, which can be caused by increased resistance to AH outflow, is a major risk factor for open-angle glaucoma. Matrix metalloproteinases (MMPs) contribute to conventional aqueous outflow homeostasis in their capacity to remodel extracellular matrices, which has a direct impact on aqueous outflow resistance and IOP. We observed decreased MMP-3 activity in human glaucomatous AH compared to age-matched normotensive control AH. Treatment with glaucomatous AH resulted in significantly increased transendothelial resistance of SC endothelial and TM cell monolayers and reduced monolayer permeability when compared to control AH, or supplemented treatment with exogenous MMP-3. Intracameral inoculation of AAV-2/9 containing a CMV-driven MMP-3 gene (AAV-MMP-3) into wild type mice resulted in efficient transduction of corneal endothelium and an increase in aqueous concentration and activity of MMP-3. Most importantly, AAV-mediated expression of MMP-3 increased outflow facility and decreased IOP, and controlled expression using an inducible promoter activated by topical administration of doxycycline achieved the same effect. Ultrastructural analysis of MMP-3 treated matrices by transmission electron microscopy revealed remodelling and degradation of core extracellular matrix components. These results indicate that periodic induction, via use of an eye drop, of AAV-mediated secretion of MMP-3 into AH could have therapeutic potential for those cases of glaucoma that are sub-optimally responsive to conventional pressure-reducing medications.

1 March 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
EREster Reina-Torres
Ester Reina-Torres
JWJoanne C. Wen
Joanne C. Wen
KLKaty C. Liu
Katy C. Liu
GLGuorong Li
Guorong Li
JBJoseph van Batenburg-Sherwood
Joseph van Batenburg-Sherwood
DODarryl R. Overby
Darryl R. Overby
Purpose: Vascular endothelial growth factor (VEGF) regulates microvascular endothelial permeability, and the permeability of Schlemm's canal (SC) endothelium influences conventional aqueous humor outflow. We hypothesize that VEGF signaling regulates outflow facility. Methods: We measured outflow facility (C) in enucleated mouse eyes perfused with VEGF-A164a, VEGF-A165b, VEGF-D, or inhibitors to VEGF receptor 2 (VEGFR-2). We monitored VEGF-A secretion from human trabecular meshwork (TM) cells by ELISA after 24 hours of static culture or cyclic stretch. We used immunofluorescence microscopy to localize VEGF-A protein within the TM of mice. Results: VEGF-A164a increased C in enucleated mouse eyes. Cyclic stretch increased VEGF-A secretion by human TM cells, which corresponded to VEGF-A localization in the TM of mice. Blockade of VEGFR-2 decreased C, using either of the inhibitors SU5416 or Ki8751 or the inactive splice variant VEGF-A165b. VEGF-D increased C, which could be blocked by Ki8751. Conclusions: VEGF is a paracrine regulator of conventional outflow facility that is secreted by TM cells in response to mechanical stress. VEGF affects facility via VEGFR-2 likely at the level of SC endothelium. Disruption of VEGF signaling in the TM may explain why anti-VEGF therapy is associated with decreased outflow facility and sustained ocular hypertension.

1 March 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JWJoanne C. Wen
Joanne C. Wen
EREster Reina-Torres
Ester Reina-Torres
JBJoseph van Batenburg-Sherwood
Joseph van Batenburg-Sherwood
PCPratap Challa
Pratap Challa
KLKaty C. Liu
Katy C. Liu
RAR. Rand Allingham
R. Rand Allingham
Purpose: We assess the effect of intravitreal anti-VEGF injections on tonographic outflow facility. Methods: Patients with age-related macular degeneration who had received unilateral intravitreal anti-VEGF injections were recruited into two groups, those with ≤10 and those with ≥20 total anti-VEGF injections. Intraocular pressure and tonographic outflow facility of injected and uninjected fellow eyes were measured and compared between groups. Risk factors for development of reduced outflow facility also were assessed. Results: Outflow facility was 12% lower in the injected eyes of patients who received ≥20 anti-VEGF injections, compared to contralateral uninjected eyes (P = 0.02). In contrast, there was no facility reduction for patients with ≤10 anti-VEGF injections (P = 0.4). In patients with ocular hypertension in the uninjected eye (IOP > 21 mm Hg, n = 5), the outflow facility of injected eyes was on average 46% lower (P = 0.01) than in the uninjected fellow eyes. This was significantly greater than the difference observed in patients with IOP ≤ 21 mm Hg in the uninjected eye (P = 2 × 10−4). In patients with ocular hypertension in the injected eye (n = 6) the differences in facility and IOP between contralateral eyes were significantly greater than in patients with IOP ≤ 21 mm Hg in the injected eye (P = 2 × 10−4 and P = 7 × 10−4, respectively). Conclusions: Chronic anti-VEGF injections significantly reduce outflow facility in patients with AMD. The greatest facility reduction is observed in patients with baseline ocular hypertension. Ophthalmologists who administer anti-VEGF injections should be aware of these findings and monitor patients closely for changes in IOP or evidence of glaucoma, especially in those with pre-existing ocular hypertension.