14 August 2021 in Journal of Radiation Research
In cervical cancer treatment, radiation therapy is selected based on the degree of tumor progression, and radiation oncologists are required to delineate tumor contours. To reduce the burden on radiation oncologists, an automatic segmentation of the tumor contours would prove useful. To the best of our knowledge, automatic tumor contour segmentation has rarely been applied to cervical cancer treatment. In this study, diffusion-weighted images (DWI) of 98 patients with cervical cancer were acquired. We trained an automatic tumor contour segmentation model using 2D U-Net and 3D U-Net to investigate the possibility of applying such a model to clinical practice. A total of 98 cases were employed for the training, and they were then predicted by swapping the training and test images. To predict tumor contours, six prediction images were obtained after six training sessions for one case. The six images were then summed and binarized to output a final image through automatic contour segmentation. For the evaluation, the Dice similarity coefficient (DSC) and Hausdorff distance (HD) was applied to analyze the difference between tumor contour delineation by radiation oncologists and the output image. The DSC ranged from 0.13 to 0.93 (median 0.83, mean 0.77). The cases with DSC <0.65 included tumors with a maximum diameter < 40 mm and heterogeneous intracavitary concentration due to necrosis. The HD ranged from 2.7 to 9.6 mm (median 4.7 mm). Thus, the study confirmed that the tumor contours of cervical cancer can be automatically segmented with high accuracy.
25 March 2021 in Journal of Applied Clinical Medical Physics
Purpose: The purpose of this study was to assess the quality of treatment planning using the PlanIQTM software and to investigate whether it is possible to improve the quality of treatment planning using the “Feasibility dose‐volume histogram (DVH)TM” implemented in the PlanIQTM software.Methods: Using the PlanIQTM software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity‐modulated radiation therapy and volumetric‐modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re‐planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re‐planning treatment plans referred to the Feasibility DVHTM implemented in the PlanIQTM software and modified the treatment planning system based on the target dose and OAR constraints.Results: Analysis of the learning curve of the treatment plans quality using PlanIQTM software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage.In all cases where re‐planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan.Conclusions: The PlanIQTM provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients.
17 November 2015 in Japanese Journal of Radiology
8 November 2023 in Radiological Physics and Technology
7 May 2021 in Medical Dosimetry
15 September 2020 in Journal of Radiation Research
Methods to evaluate the positional reproducibility of breath-hold irradiation mostly require manual operation. The purpose of this study is to propose a method to determine the reproducibility of breath-hold irradiation of lung tumors between fractions using non-artificial methods. This study included 13 patients who underwent terminal exhaled breath-hold irradiation for primary and metastatic lung cancer. All subjects received a prescribed dose of 60 Gy/8 fractions. The contours of the gross tumor volume (GTV) were extracted by threshold processing using treatment-planning computed tomography (CT) and cone-beam CT (CBCT), which was done just before the beginning of the treatment. The method proposed in this study evaluates the dice similarity coefficient (DSC) and Hausdorff distance (HD) by comparing two volumes, the GTVCTS (GTV obtained from treatment-planning CT) and GTVCBCT (GTV obtained from CBCT). The reference contours for DSC and HD are represented by GTVCTS. The results demonstrated good visual agreement for cases with a DSC of ~0.7. However, apparent misalignment occurred when the DSC was 2 mm in 3 out of 13 cases, and when the DSC was ~0.7, the HD was ~1 mm. In addition, cases with greater HD also demonstrated more significant variability. It was found that the DSC and HD evaluation methods for the positional reproducibility of breath-hold irradiation proposed in this study are straightforward and can be performed without the involvement of humans. Our study is of extreme significance in the field of radiation studies.