A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV–55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.
Operation of repetitive high-power microwave (HPM) sources is predominantly limited by thermal properties of anode and cathode materials. This letter presents a reflex-triode virtual cathode oscillator (vircator) capable of operating at 500 Hz at current densities between 100-200 A/cm 2 for multiple burst durations of 1-2 s. Stable vircator operation under such a thermally punishing environment is facilitated by the use of a thin pyrolytic graphite anode. The results presented focus on two anode-cathode (A-K) gap spacings: 11 and 21 mm, which produce stable microwave radiation at 4.6 and 1.6 GHz, respectively. Characteristic voltage, current, and microwave waveforms in conjunction with short-time Fourier transforms, frequency spectrographs, and HPM power density data for 1000 and 500 pulses at 1.6 and 4.6 GHz, respectively, are presented.
4 November 2014 in IEEE Transactions on Plasma Science
When subjected to high electric fields in vacuum, carbon fiber cathodes produce intense electron beams suitable for high-power microwave (HPM) generation at very high current densities. However, the production mechanisms of these intense electron beams are not fully understood. This paper presents the postmortem examination of three conditioned carbon fiber cathode types. The three cathode types consist of an uncoated, bare unimodal fiber structure, a bare bimodal fiber structure, and a cesium-iodide (CsI)-coated bimodal fiber structure, all with identical fiber coverage of 2% by area. Each cathode was conditioned prior to testing by single pulse operation driven by an 80 J Marx generator for 10 000 pulses. HPM, voltage, and current waveforms of each cathode are presented. The bare bimodal cathode radiated more microwave power than the CsI-coated cathode and bare unimodal cathode. Scanning electron microscopy imagery presents evidence of two emission mechanisms: 1) explosive electron emission and 2) surface flashover, which both were found on the CsI-coated cathode. In addition, no evidence of surface flashover was found on either uncoated cathode.
2 July 2014 in IEEE Transactions on Plasma Science
This paper presents a study on outgassing and electrical conditioning for three carbon fiber cathode types in a vacuum-sealed, high-power microwave virtual-cathode-oscillator (vircator) that operates in the low 10 -9 torr pressure regime. The three cathode types consist of a bare bimodal fiber structure, a bare unimodal fiber structure, and a cesium-iodide coated bimodal fiber structure with identical fiber coverage of 2% by area with a surface area of ~20 cm 2 . The electrodes are cleaned by a 1.2 kW, argon/oxygen microwave plasma prior to complete vircator assembly, followed by a 300 °C bake-out for 72 h. Each cathode was pulsed in a single pulse operation by an 80 J, low inductance Marx generator with an approximate pulsewidth of 100 ns full-width at half-maximum for 10000 current pulses. The data presented includes individual gas constituents, high-speed intensified charge coupled device (ICCD) imaging, and voltage and current waveforms. The conditioning process resulted in a gas load reduction of ~80% overall, with the indication that the bare bimodal fiber structure performed the best as diode power increased throughout the experiment, while the power decreased for the other tested cathode types.
This paper presents the design and operation characteristics of a solid-state high voltage pulse generator. Its primary utilization is aimed at triggering a gaseous spark gap with high repeatability. Specifically, the trigger generator is designed to achieve a risetime on the order of 0.1 kV/ns to trigger the first stage, trigatron spark gap of a 10-stage, 500 kV Marx generator. The major design components are comprised of a 60 W constant current DC-DC converter for high voltage charging, a single 4 kV thyristor, a step-up pulse transformer, and magnetic switch for pulse steepening. A risetime of <30 ns and pulse magnitude of 4 kV is achieved matching the simulated performance of the design.
19 September 2014 in IEEE Transactions on Plasma Science
Cold cathode operation under high current densities leads to explosive electron emission (EEE) that contributes to early A-K gap closure. Hence, inconsistent vacuum conditions and, if utilized in a high power microwave device, degradation of microwave output power are observed. The EEE centers are known to produce localized plasmas on the surface of the cathode that release and ionize the electrode material. Further, low melting point material in the anode is released due to electron bombardment accompanied by a significant surface temperature increase. Postmortem analysis has revealed particles up to 50 μm in diameter embedded in the opposite electrode. High speed ICCD imaging during A-K gap operation enabled resolving the plasma's spatial characteristics in time. Images of cathode and anode plasma during the operation of a virtual cathode oscillator at 250 A/cm 2 under ultrahigh vacuum conditions are presented.