Syed Asadullah Arslan

Syed Asadullah Arslan

Auto-generated profile, based on publicly available information

Syed Asadullah Arslan

University Institute of Physical Therapy, University of Lahore, Lahore, Pakistan

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SFSahar Fatima
Sahar Fatima
SASyed Asadullah Arslan
Syed Asadullah Arslan
FSFaiza Sharif
Faiza Sharif
AAAshfaq Ashfaq Ahmad
Ashfaq Ashfaq Ahmad
SGSyed Amir Gilani
Syed Amir Gilani
AZAnna Zaheer
Anna Zaheer
Background: Knee injury and osteoarthritis outcome score questionnaire is a widely used tool for measuring short and long-term patient-relevant outcomes following knee injury. KOOS is neither translated nor examined for psychometric properties before. Therefore, the aim of this study was to translate, culturally adapt and check the psychometric properties of the KOOS in Urdu. Methodology: The translation and cultural adaptation was performed according to pre-defined guidelines. A total of 117 participants (54 males and 63 females) were recruited. The study had two steps: 1) Translation and cultural adaptation 2) Reliability and validity testing. The reliability (test-retest and internal consistency at (95% confidence interval) as well as the validity (Convergent validity) of final Urdu version of KOOS was tested. Results: For all five domains, the KOOS Urdu version (KOOS-U) has demonstrated high test-retest reliability ICC = 0.90–0.96(CI = 95%). For all domains, the internal consistency was determined to be excellent (α = 0.82–0.96). There were no floor or ceiling impacts noted. Convergent validity was found to be good, as measured by Pearson’s correlation coefficient. The findings revealed a strong negative association between the KOOS-U (QOL and pain) and the NPRS. And there was a low to high positive correlation between five KOOS-U domains and all SF-12 domains, i.e., there was a significant positive correlation between the pain domains of both KOOS and SF-12 with the r = 0.87(p < 0.05). Conclusion: The Urdu version of KOOS is a valid, reliable, and responsive instrument to assess functional disability of patients with Knee Osteoarthritis with excellent psychometric properties.

1 January 2018 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
ZEZahra Ebrahimabadi
Zahra Ebrahimabadi
SNSedigheh Sadat Naimi
Sedigheh Sadat Naimi
ARAbbas Rahimi
Abbas Rahimi
HSHeydar Sadeghi
Heydar Sadeghi
SHSeyed Majid Hosseini
Seyed Majid Hosseini
SASyed Asadullah Arslan
Syed Asadullah Arslan

7 February 2022 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
FTFahad Tanveer
Fahad Tanveer
SASyed Asadullah Arslan
Syed Asadullah Arslan
HDHaider Darain
Haider Darain
AAAshfaq Ahmad
Ashfaq Ahmad
SGSyed Amir Gilani
Syed Amir Gilani
AHAsif Hanif
Asif Hanif

1 January 2021 in Pakistan Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
FTFahad Tanveer
Fahad Tanveer
SASyed Asadullah Arslan
Syed Asadullah Arslan
HDHaider Darain
Haider Darain
AAAshfaq Ahmad
Ashfaq Ahmad
Objective: To determine intra-rater and inter-rater reliability of hand-held dynamometer for assessing isometric lumbar muscle strength in asymptomatic healthy population. Methods: It was a cross-sectional study conducted at the department of physiotherapy, University of Lahore Teaching Hospital, Lahore, Pakistan, from July 2020 to August 2020 through non probability-purposive sampling technique. Thirty healthy subjects were tested at thirty-degree lumbar flexion and zero-degree lumbar extension positions. Two raters assessed isometric strength of lumbar flexor and extensor muscles, by a hand-held dynamometer. Strength was measured and recorded by each of the two raters and re-assessed after a week. Correlation and pairwise comparison were done between readings. ICC values were calculated for the assessment of isometric lumbar muscle strength using handheld dynamometer. Results: A total of 30 healthy subjects had participated with mean age of 22.84±1.21 years, height 174.33±6.83 cm, weight 68.58±5.08 kg and BMI 22.52±0.35. Findings showed an excellent intra-rater (ICC 2, k = 0.95 to 0.97) and inter-rater (ICC 2, k = 0.94 to 0.95) reliability. Conclusions: Hand held dynamometer demonstrated an excellent intra- and inter-rater reliability for assessment of isometric lumbar muscles strength of healthy subject at clinical setting as it is simple to use, portable and cost-effective for the precise measurement of lumbar muscles strength. doi: https://doi.org/10.12669/pjms.37.2.3621 How to cite this:Tanveer F, Arslan SA, Darain H, Ahmad A. Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population. Pak J Med Sci. 2021;37(2):461-465. doi: https://doi.org/10.12669/pjms.37.2.3621 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

23 December 2021 in Medicine
Verified
Journal Article
Open access
FTFahad Tanveer
Fahad Tanveer
SASyed Asadullah Arslan
Syed Asadullah Arslan
HDHaider Darain
Haider Darain
AAAshfaq Ahmad
Ashfaq Ahmad
SGSyed Amir Gilani
Syed Amir Gilani
AHAsif Hanif
Asif Hanif
Background: Aim of this study was to systematically review the prevailing treatment methods for lumbar spondylolysis. Methods: Manuscripts published between 1951 and 2020 were searched by using PubMed, Medline, Scopus, Springer, Web of Science databases. The study protocol was registered with PROSPERO (CRD42020218651). The inclusion criteria for all articles of prevailing treatment methods for spondylolysis were: Standards have been independently applied by using 2 reviewers and another author resolved disagreements. Results: Data extraction screened 12 full-length articles. Description, treatment, outcome, and findings were individually extracted and cross-referenced. Discussion: Current review has suggested that the noninvasive treatment method specifically low intensity pulsed ultrasound, electro acupuncture and pulsed electromagnetic filed is effective for bone union while operative treatment specifically pedicle screw fixation +/- interbody fusion depending the extent of disk degeneration and craniocaudal foraminal stenosis is effective for minimizing pain and functional disability in patients with spondylolysis. This review concluded that the noninvasive treatment method specifically low intensity pulsed ultrasound is effective for bone union. Review Registration: PROSPERO (CRD42020218651).

3 October 2022 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
ABAli Barzegar
Ali Barzegar
LRLeila Rahnama
Leila Rahnama
NKNoureddin Karimi
Noureddin Karimi
MYMohammadhossein Ahrar Yazdi
Mohammadhossein Ahrar Yazdi
ASAbdulrahim Sadeghi
Abdulrahim Sadeghi
SASyed Asadullah Arslan
Syed Asadullah Arslan