Hassan Bayat

Hassan Bayat

Auto-generated profile, based on publicly available information

Hassan Bayat

Sina Medical Laboratory , Qaem Shahr , Iran

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2017 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
PDF file
WOWytze P. Oosterhuis
Wytze P. Oosterhuis
HBHassan Bayat
Hassan Bayat
DADavid Armbruster
David Armbruster
ACAbdurrahman COSKUN
Abdurrahman COSKUN
KFKathleen P. Freeman
Kathleen P. Freeman
ETElvar Theodorsson
Elvar Theodorsson
Error methods – compared with uncertainty methods – offer simpler, more intuitive and practical procedures for calculating measurement uncertainty and conducting quality assurance in laboratory medicine. However, uncertainty methods are preferred in other fields of science as reflected by the guide to the expression of uncertainty in measurement. When laboratory results are used for supporting medical diagnoses, the total uncertainty consists only partially of analytical variation. Biological variation, pre- and postanalytical variation all need to be included. Furthermore, all components of the measuring procedure need to be taken into account. Performance specifications for diagnostic tests should include the diagnostic uncertainty of the entire testing process. Uncertainty methods may be particularly useful for this purpose but have yet to show their strength in laboratory medicine. The purpose of this paper is to elucidate the pros and cons of error and uncertainty methods as groundwork for future consensus on their use in practical performance specifications. Error and uncertainty methods are complementary when evaluating measurement data.

1 January 2017 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
PDF file
HBHassan Bayat
Hassan Bayat
Background: Traditionally, statistical quality control (SQC) planning is aimed at preventing the error rate from exceeding a pre-defined acceptable rate (Westgard JO. Basic QC Practices, 4th ed. Westgard QC, 2016). A pivotal characteristic for planning a QC procedure with the traditional approach is the probability of rejecting an analytical run that contains critical size errors (PMethods: We used a statistical model to investigate the relationship between PResults: There is a close relationship between PConclusions: Multi-rule SQC procedures can be used for controlling intermediate and low sigma capability method to attain a low Max E(N

15 December 2018 in Biochemia Medica
Verified
Journal Article
Open access
PDF file
SWSten Westgard
Sten Westgard
HBHassan Bayat
Hassan Bayat
JWJames O Westgard
James O Westgard
Mistaken assumptions drive new Six Sigma model off the road

1 December 2021 in Clinica Chimica Acta
Verified
Journal Article
Closed access
SWSten A. Westgard
Sten A. Westgard
HBHassan Bayat
Hassan Bayat
JWJames O. Westgard
James O. Westgard

14 June 2022 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
JWJames O. Westgard
James O. Westgard
HBHassan Bayat
Hassan Bayat
SWSten A. Westgard
Sten A. Westgard
Article How to evaluate fixed clinical QC limits vs. risk-based SQC strategies was published on June 14, 2022 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).

12 June 2024 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
HBHassan Bayat
Hassan Bayat
SWSten A. Westgard
Sten A. Westgard
JWJames O. Westgard
James O. Westgard
While Six Sigma is used in different disciplines to improve quality, Tony Badric and Elvar Theodorsson in a recent paper in CCLM have questioned Six Sigma application in medical laboratory concluding Six Sigma has provided no value to medical laboratory. In addition, the authors have expanded their criticism to Total Analytical Error (TAE) model and statistical quality control. To address their arguments, we have explained the basics of TAE model and Six Sigma and have shown the value of Six Sigma to medical laboratory.