Purpose: To evaluate morphologic changes in the anterior segment using ultrasound biomicroscopic imaging (UBM) after phacoemulsification and foldable intraocular lens implantation (IOL). Methods: Thirty-six patients with a mean age of 68.68 ± 8.44 years (range 51-89) who had phacoemulsification and foldable IOL implantation were included in this prospective study. Several anterior segment parameters including aqueous depth (AQD), trabecular meshwork-iris angle (TIA), ciliary body thickness (CBT), sclera thickness (ST), trabecular meshwork-ciliary process distance (T-CPD), iris-ciliary processes distance (I-CPD), and iris thickness (IT) were measured using UBM preoperatively and at postoperative month 2. Results: There was a significant increase in AQD (p<0.001) and TIA (p0.05) during the study period. Conclusions: Removal of the crystalline lens results in change in the anterior segment parameters. Our results confirmed that UBM is a helpful option for the analysis of anterior segment structures both qualitatively and quantitatively.
Purpose: To investigate the causes and management of recurrences of complicated retinal detachment after vitreoretinal surgery. Methods: Vitreoretinal surgery was performed in 61 patients with complicated retinal detachment who were followed up for 4–24 (mean 7) months. Liquid perfluorocarbon (PFC) was used in all 61, silicone oil in 40 and perfluoropropane (C3F8) in 18 patients. Results: Retinal attachment was achieved in 58 patients (95%) during the first operation. Due to the recurrence of detachment 17 patients (29%) had to be operated for a second, 7 (12%) a third and 4 (7%) a fourth time. Anterior and posterior proliferative vitreoretinopathy, missed tear, retinal incarceration, subretinal membrane and perisilicone proliferation were the factors causing redetachment. Conclusions: The best anatomical and functional results are obtained by dissection of the anterior membranes. In order to properly remove the retinal periphery the crystalline or intraocular lens should be removed. Comparison of our results with others indicates that anatomical success depends, to a certain extent, on doing only one, radical operation on the pathology that leads to recurrence.
Objective. To evaluate the morphological changes of the anterior segment using ultrasonic biomicroscopy (UBM) imaging in pseudophakic patients who underwent pars plana vitrectomy (PPV) with silicone oil or gas (C3F8) internal tamponade agent injection.Method. This prospective study included pseudophakic patients with planned PPV, divided into two groups according to internal tamponade agent: those in which silicone oil was used (, Group 1) and those in which gas (C3F8) was used (, Group 2). UBM measurements were performed in the supine position before and one week after surgery.Results. In patients of Group 1, postoperative trabecular meshwork-ciliary process distance (T-CPD) and iris-ciliary process distance (I-CPD), according to preoperative values, were found to be statistically significantly reduced, and postoperative mean value of scleral thickness (ST) and intraocular pressure (IOP), according to preoperative value, was found to be statistically significantly increased. In patients of Group 2, postoperative mean values of anterior chamber depth (ACD), ciliary body thickness (CBT), T-CPD, I-CPD, and IOP, according to preoperative values, were found to be statistically significantly reduced. Preoperatively, in Group 2 patients, according to Group 1 patients, TIA and IOP were found to be statistically significantly increased. Preoperative and postoperative IOP between the measured parameters with UBM showed no statistically significant correlation.Conclusions. Gases cause more morphological changes in the anterior segment structures. It is thought that complications such as increased intraocular pressure can be seen more frequently for this reason.