The restorative function of sleep is shaped by its duration, timing, continuity, subjective quality, and efficiency. Current sleep recommendations specify only nocturnal duration and have been largely derived from sleep self-reports that can be imprecise and miss relevant details. Sleep duration, preferred timing, and ability to withstand sleep deprivation are heritable traits whose expression may change with age and affect the optimal sleep prescription for an individual. Prevailing societal norms and circumstances related to work and relationships interact to influence sleep opportunity and quality. The value of allocating time for sleep is revealed by the impact of its restriction on behavior, functional brain imaging, sleep macrostructure, and late-life cognition. Augmentation of sleep slow oscillations and spindles have been proposed for enhancing sleep quality, but they inconsistently achieve their goal. Crafting bespoke sleep recommendations could benefit from large-scale, longitudinal collection of objective sleep data integrated with behavioral and self-reported data.
Background: Wearable devices have tremendous potential for large-scale longitudinal measurement of sleep, but their accuracy needs to be validated. We compared the performance of the multisensor Oura ring (Oura Health Oy, Oulu, Finland) to polysomnography (PSG) and a research actigraph in healthy adolescents. Methods: Fifty-three adolescents (28 females; aged 15– 19 years) underwent overnight PSG monitoring while wearing both an Oura ring and Actiwatch 2 (Philips Respironics, USA). Measurements were made over multiple nights and across three levels of sleep opportunity (5 nights with either 6.5 or 8h, and 3 nights with 9h). Actiwatch data at two sensitivity settings were analyzed. Discrepancies in estimated sleep measures as well as sleep-wake, and sleep stage agreements were evaluated using Bland–Altman plots and epoch-by-epoch (EBE) analyses. Results: Compared with PSG, Oura consistently underestimated TST by an average of 32.8 to 47.3 minutes (Ps < 0.001) across the different TIB conditions; Actiwatch 2 at its default setting underestimated TST by 25.8 to 33.9 minutes. Oura significantly overestimated WASO by an average of 30.7 to 46.3 minutes. It was comparable to Actiwatch 2 at default sensitivity in the 6.5, and 8h TIB conditions. Relative to PSG, Oura significantly underestimated REM sleep (12.8 to 19.5 minutes) and light sleep (51.1 to 81.2 minutes) but overestimated N3 by 31.5 to 46.8 minutes (Ps < 0.01). EBE analyses demonstrated excellent sleep-wake accuracies, specificities, and sensitivities – between 0.88 and 0.89 across all TIBs. Conclusion: The Oura ring yielded comparable sleep measurement to research grade actigraphy at the latter’s default settings. Sleep staging needs improvement. However, the device appears adequate for characterizing the effect of sleep duration manipulation on adolescent sleep macro-architecture.
Naps are increasingly considered a means to boost cognitive performance. We quantified the cognitive effects of napping in 60 samples from 54 studies. 52 samples evaluated memory. We first evaluated effect sizes for all tests together, before separately assessing their effects on memory, vigilance, speed of processing and executive function. We next examined whether nap effects were moderated by study features of age, nap length, nap start time, habituality and prior sleep restriction. Naps showed significant benefits for the total aggregate of cognitive tests (Cohen's d = 0.379, CI95 = 0.296-0.462). Significant domain specific effects were present for declarative (Cohen's d = 0.376, CI95 = 0.269-0.482) and procedural memory (Cohen's d = 0.494, CI95 = 0.301-0.686), vigilance (Cohen's d = 0.610, CI95 = 0.291-0.929) and speed of processing (Cohen's d = 0.211, CI95 = 0.052-0.369). There were no significant moderation effects of any of the study features. Nap effects were of comparable magnitude across subgroups of each of the 5 moderators (Q values = 0.009 to 8.572, p values > 0.116). Afternoon naps have a small to medium benefit over multiple cognitive tests. These effects transcend age, nap duration and tentatively, habituality and prior nocturnal sleep.
We compared the basic cognitive functions of adolescents undergoing split (nocturnal sleep + daytime nap) and continuous nocturnal sleep schedules when total sleep opportunity was either below or within the recommended range (i.e. 6.5 or 8 h). Adolescent participants (age: 15–19 year) in the 8-h split (n = 24) and continuous (n = 29) sleep groups were compared with 6.5-h split and continuous sleep groups from a previous study (n = 58). These protocols involved two baseline nights (9-h time-in-bed [TIB]), 5 nights of sleep manipulation, 2 recovery nights (9-h TIB), followed by a second cycle of sleep manipulation (3 nights) and recovery (2 nights). Cognitive performance, subjective sleepiness, and mood were evaluated daily; sleep was assessed using polysomnography. Splitting 6.5 h of sleep with a mid-afternoon nap offered a boost to cognitive function compared to continuous nocturnal sleep. However, when total TIB across 24 h increased to 8 h, the split and continuous sleep groups performed comparably in tests evaluating vigilance, working memory, executive function, processing speed, subjective sleepiness, and mood. In adolescents, the effects of split sleep on basic cognitive functions vary by the amount of total sleep obtained. As long as the total sleep opportunity across 24 h is within the recommended range, students may fulfill sleep requirements by adopting a split sleep schedule consisting of a shorter period of nocturnal sleep combined with a mid-afternoon nap, without significant impact on basic cognitive functions. NCT04044885.
Purpose: To evaluate the benefits of applying an improved sleep detection and staging algorithm on minimally processed multi-sensor wearable data collected from older generation hardware. Patients and Methods: 58 healthy, East Asian adults aged 23– 69 years (M = 37.10, SD = 13.03, 32 males), each underwent 3 nights of PSG at home, wearing 2nd Generation Oura Rings equipped with additional memory to store raw data from accelerometer, infra-red photoplethysmography and temperature sensors. 2-stage and 4-stage sleep classifications using a new machine-learning algorithm (Gen3) trained on a diverse and independent dataset were compared to the existing consumer algorithm (Gen2) for whole-night and epoch-by-epoch metrics. Results: Gen 3 outperformed its predecessor with a mean (SD) accuracy of 92.6% (0.04), sensitivity of 94.9% (0.03), and specificity of 78.5% (0.11); corresponding to a 3%, 2.8% and 6.2% improvement from Gen2 across the three nights, with Cohen’s d values > 0.39, t values > 2.69, and p values < 0.01. Notably, Gen 3 showed robust performance comparable to PSG in its assessment of sleep latency, light sleep, rapid eye movement (REM), and wake after sleep onset (WASO) duration. Participants < 40 years of age benefited more from the upgrade with less measurement bias for total sleep time (TST), WASO, light sleep and sleep efficiency compared to those ≥ 40 years. Males showed greater improvements on TST and REM sleep measurement bias compared to females, while females benefitted more for deep sleep measures compared to males. Conclusion: These results affirm the benefits of applying machine learning and a diverse training dataset to improve sleep measurement of a consumer wearable device. Importantly, collecting raw data with appropriate hardware allows for future advancements in algorithm development or sleep physiology to be retrospectively applied to enhance the value of longitudinal sleep studies.
Study Objectives: To determine how mid-afternoon naps of differing durations benefit memory encoding, vigilance, speed of processing (SOP), mood, and sleepiness; to evaluate if these benefits extend past 3 hr post-awakening and to examine how sleep macrostructure during naps modulate these benefits.Methods: Following short habitual sleep, 32 young adults underwent four experimental conditions in randomized order: wake; naps of 10 min, 30 min, and 60 min duration verified with polysomnography. A 10-min test battery was delivered at a pre-nap baseline, and at 5 min, 30 min, 60 min, and 240 min post-nap. Participants encoded pictures 90 min post-nap and were tested for recognition 210 min later.Results: Naps ranging from 10 to 60 min increased positive mood and alleviated self-reported sleepiness up to 240 min post-nap. Compared to waking, only naps of 30 min improved memory encoding. Improvements in vigilance were moderate, and benefits for SOP were not observed. Sleep inertia was observed for the 30 min to 60 min naps but was resolved within 30 min after waking. We found no significant associations between sleep macrostructure and memory benefits.Conclusions: With short habitual sleep, naps ranging from 10 to 60 min had clear and lasting benefits for positive mood and self-reported sleepiness/alertness. Cognitive improvements were moderate, with only the 30 min nap showing benefits for memory encoding. While there is no clear “winning” nap duration, a 30 min nap appears to have the best trade-off between practicability and benefit.Clinical Trial ID: Effects of Varying Duration of Naps on Cognitive Performance and Memory Encoding, https://www.clinicaltrials.gov/ct2/show/NCT04984824, NCT04984824.