Hualei Zheng

Hualei Zheng

Auto-generated profile, based on publicly available information

Hualei Zheng

State Key Laboratory of Intelligent Power Distribution Equipment and System, Hebei University of Technology, Tianjin, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XZXian Zhang
Xian Zhang
HZHualei Zheng
Hualei Zheng
FXFei Xu
Fei Xu
ZCZhixin Chen
Zhixin Chen
The LCC-LCC compensation topology has been widely applied to inductive-power-transfer (IPT) systems to achieve constant-current (CC) output for battery charging. However, the mathematical model for the CC output is usually derived by fundamental-harmonic-analysis (FHA) applied in the frequency domain, which cannot describe the output current accurately when the load resistance is larger than a threshold value, i.e., R L >πω Lfs /2, because of the discontinuous part-sine current flowing into the rectifier. To tackle this problem, in this paper, an accurate time-domain-analysis (TDA) is firstly proposed to derive the mathematical model of output current for the LCC-LCC compensated IPT system. The derived output model shows that the output current would decrease with the increase of load resistance which is totally different from the conclusion from FHA. Both simulation and experimental results are presented to validate the accuracy of our derived output current model by TDA, which are consistent with our theoretical results. The proposed method can provide guidance on how to design the parameters of LCC-LCC compensated IPT converters to achieve rated outputs with small tolerance error for battery charging.

26 August 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HZHualei Zheng
Hualei Zheng
FXFei Xu
Fei Xu
XLXiao ning Li
Xiao ning Li
ZCZhixin Chen
Zhixin Chen
XZXian Zhang
Xian Zhang
CTChi K. Tse
Chi K. Tse
Existing control methods for wireless power transfer (WPT) systems struggle to achieve zero-voltage switching (ZVS), output stability, and efficiency optimization at the same time. To address this problem, this letter proposes a hierarchical-constraint model predictive control (HCMPC) method by structuring the control into prioritized layers. HCMPC can achieve ZVS, output regulation, and efficiency optimization simultaneously without using complex weighting factors. Experimental results illustrate that HCMPC delivers an output voltage error below 0.5% and efficiency above 90% over a wide load range from 30 to 80 Ω. Under load transients, the settling times are 12 and 15 ms, respectively. Meanwhile, the WPT system can ensure ZVS for all switches in the whole load range. The proposed approach provides a robust and scalable solution for WPT systems, broadening their practical deployment in electric vehicles and consumer electronics products.

13 January 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
FXFei Xu
Fei Xu
HZHualei Zheng
Hualei Zheng
XZXian Zhang
Xian Zhang
ZCZhixin Chen
Zhixin Chen
Traditional control schemes for wireless power transfer (WPT) systems struggle to achieve zero voltage switching (ZVS), output stability, and efficiency optimization simultaneously. To address this limitation, this article proposes a discrete neighborhood search–model predictive control (DNS-MPC) strategy for multiobjective optimization in inductor-capacitor-capacitor-series (LCC-S) compensated WPT systems, addressing three critical requirements: output regulations, transmission efficiency maximization, and ZVS realization. First, a mathematical model of the WPT system is developed based on circuit analysis. The derived expressions are then used to identify the operating regions that ensure ZVS across all power switches. Second, a composite cost function is formulated to systematically coordinate voltage tracking precision and power loss minimization. Third, the DNS-MPC strategy is developed to simultaneously achieve precise output voltage regulation, high efficiency, and ZVS operation over a wide load range without auxiliary circuits. Experimental validation under multiple operating points (80/100/120 V references) demonstrates consistent performance: the maximum voltage fluctuation is limited to 0.26 V, peak efficiency reaches 93.92%, and efficiency variation remains within 4.22% and ensures ZVS operation. Additional tests under coil misalignment confirm robust operation with efficiency above 89%, and detailed loss analysis shows that system losses were reduced by 29.1%, 25.22%, and 38.99% at load resistances of 20, 50, and 100 Ω, respectively.