Xin Liu

Xin Liu

Auto-generated profile, based on publicly available information

Xin Liu

College of Biomedical Engineering Fudan University Shanghai China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
XLXin Liu
Xin Liu
TZTianyang Zhou
Tianyang Zhou
MLMengyang Lu
Mengyang Lu
YYYi Yang
Yi Yang
QHQiong He
Qiong He
JLJianwen Luo
Jianwen Luo
By localizing microbubbles (MBs) in the vasculature, ultrasound localization microscopy (ULM) has recently been proposed, which greatly improves the spatial resolution of ultrasound (US) imaging and will be helpful for clinical diagnosis. Nevertheless, several challenges remain in fast ULM imaging. The main problems are that current localization methods used to implement fast ULM imaging, e.g., a previously reported localization method based on sparse recovery (CS-ULM), suffer from long data-processing time and exhaustive parameter tuning (optimization). To address these problems, in this paper, we propose a ULM method based on deep learning, which is achieved by using a modified sub-pixel convolutional neural network (CNN), termed as mSPCN-ULM. Simulations and in vivo experiments are performed to evaluate the performance of mSPCN-ULM. Simulation results show that even if under high-density condition (6.4 MBs/mm2), a high localization precision ( 28 lm in the lateral direction and 24 lm in the axial direction) and a high localization reliability (Jaccard index of 0.66) can be obtained by mSPCN-ULM, compared to CS-ULM. The in vivo experimental results indicate that with plane wave scan at a transmit center frequency of 15.625 MHz, microvessels with diameters of 17 lm can be detected and adjacent microvessels with a distance of 42 lm can be separated. Furthermore, when using GPU acceleration, the data-processing time of mSPCN-ULM can be shortened to 6 sec/frame in the simulations and 23 sec/frame in the in vivo experiments, which is 3-4 orders of magnitude faster than CS-ULM. Finally, once the network is trained,mSPCN-ULM does not need parameter tuning to implement ULM. As a result, mSPCN-ULM opens the door to implement ULM with fast data-processing speed, high imaging accuracy, short data-acquisition time, and high flexibility (robustness to parameters) characteristics.

25 January 2021 in OSA Continuum
Verified
Journal Article
Closed access
ZJZhengfen Jiang
Zhengfen Jiang
XLXin Liu
Xin Liu
ZYZhuangzhi Yan
Zhuangzhi Yan
WGWenting Gu
Wenting Gu
JJJie Hui Jiang
Jie Hui Jiang
Blood cell count plays an important role in the field of clinical medical diagnosis. To effectively automate the counting of blood cells, recently, the deep-learning-based detection method represented by the YOLO has been proposed and used successfully. Nevertheless, the YOLO detection method has difficulties in insufficient positioning of the bounding boxes and in distinguishing overlapping objects. To overcome the limitations, we propose a new deep-learning-based method, termed Attention-YOLO, which is achieved by adding the channel attention mechanism and the spatial attention mechanism to the feature extraction network. By using the filtered and weighted feature vector to replace the original feature vector for residual fusion, Attention-YOLO can help the network to improve the detection accuracy. The experimental results indicate that compared to the standard YOLO network, the Attention-YOLO can achieve a better detection performance in blood cell count without introducing too many additional parameters, where the recognition accuracy of cells (RBCs, WBCs, and platelets) has an improvement of 6.70%, 2.13%, and 10.44%, respectively, and the mean Average Precision (mAP) has an improvement of 7.10%.

4 November 2013 in Optics Letters
Verified
Journal Article
Closed access
PDF file
XLXin Liu
Xin Liu
QLQimei Liao
Qimei Liao
HWHongkai Wang
Hongkai Wang
X-ray luminescence computed tomography (XLCT) is a new molecular imaging modality. In this Letter, we first in vivo tomographically image the near-IR-emitting nanophosphor (Gd2O3:Eu3+) in nude mice (N=2). In practically, incorporating the compressive sensing technique, the XLCT reconstruction is performed only using single-view data. The experimental results indicate that the single-view reconstruction is feasible to image XLCT in vivo. The location error is less than 1.5 mm. Further, the imaging time can be greatly reduced compared with previous XLCT systems. Therefore, it is suited for imaging fast distribution of x-ray-excitable nanophosphors within a biological object.

15 September 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
MLMengyang Lu
Mengyang Lu
XLXin Liu
Xin Liu
CLChengcheng Liu
Chengcheng Liu
BLBoyi Li
Boyi Li
WGWenting Gu
Wenting Gu
Dean TaDean Ta
Dean Ta
Photoacoustic tomography (PAT) is an emerging biomedical imaging technology that can realize high contrast imaging with a penetration depth of the acoustic. Recently, deep learning (DL) methods have also been successfully applied to PAT for improving the image reconstruction quality. However, the current DL-based PAT methods are implemented by the supervised learning strategy, and the imaging performance is dependent on the available ground-truth data. To overcome the limitation, this work introduces a new image domain transformation method based on cyclic generative adversarial network (CycleGAN), termed as PA-GAN, which is used to remove artifacts in PAT images caused by the use of the limited-view measurement data in an unsupervised learning way. A series of data from phantom and in vivo experiments are used to evaluate the performance of the proposed PA-GAN. The experimental results show that PA-GAN provides a good performance in removing artifacts existing in photoacoustic tomographic images. In particular, when dealing with extremely sparse measurement data (e.g., 8 projections in circle phantom experiments), higher imaging performance is achieved by the proposed unsupervised PA-GAN, with an improvement of ∼14% in structural similarity (SSIM) and ∼66% in peak signal to noise ratio (PSNR), compared with the supervised-learning U-Net method. With an increasing number of projections (e.g., 128 projections), U-Net, especially FD U-Net, shows a slight improvement in artifact removal capability, in terms of SSIM and PSNR. Furthermore, the computational time obtained by PA-GAN and U-Net is similar (∼60 ms/frame), once the network is trained. More importantly, PA-GAN is more flexible than U-Net that allows the model to be effectively trained with unpaired data. As a result, PA-GAN makes it possible to implement PAT with higher flexibility without compromising imaging performance.

16 July 2018 in IEEE Access
Verified
Journal Article
Open access
YSYuexia Shu
Yuexia Shu
CHChangpeng Han
Changpeng Han
MLMinglei Lv
Minglei Lv
XLXin Liu
Xin Liu
Super-resolution ultrasound (SR-US) imaging technique breaks the diffraction limit and can image microvascular structure. However, the temporal resolution of SR-US is limited because a long data acquisition time is required to accumulate enough microbubbles. To overcome this limitation, in this paper, we proposed a new SR-US method based on compressed sensing (CS), which is used to identify the highly overlapped microbubbles in each frame. To further speed up the data acquisition of SR-US, here, U.S. data was generated by single plane wave (SPW) transmission. To evaluate the performance of the proposed technique (CS reconstruction method combined with SPW transmission, termed as CSRMSPW), a series of numerical simulation was performed. Especially, considering that SPW has a relatively low spatial resolution, it may affect the obtained SR-US imaging performance. We compare the effect of synthetic transmit aperture (STA) and SPW on SR-US. The results indicate the overlapped microbubbles can be identified by the CSRM method when compared with the traditional localization method (e.g., Gaussian fitting method). In addition, whatever STA or SPW images are used as the input data of CS reconstruction, the localization accuracy of SR-US obtained by the CSRM method is similar. Further, by using the CSRM combined with SPW technique, the vascular network can be accurately resolved, even if the high-density microbubbles existed in each frame. As a result, the proposed CSRM-SPW technique is suitable for fast SR-US imaging.

27 July 2024 in Ultrasonics
Verified
Journal Article
Closed access
GZGaobo Zhang
Gaobo Zhang
XHXing Hu
Xing Hu
XRXuan Ren
Xuan Ren
BZBoqian Zhou
Boqian Zhou
BLBoyi Li
Boyi Li
Dean TaDean Ta
Dean Ta