1 January 2020 in American Journal of Ophthalmology
The aim of this study was to investigate the safety and performance of the second generation of an implantable intraocular pressure (IOP) sensor in patients with primary open angle glaucoma (POAG). prospective, noncomparative, open-label, multicenter clinical investigation. In this study, patients with POAG, regularly scheduled for cataract surgery, were implanted with a ring-shaped, sulcus-placed, foldable IOP sensor in a single procedure after intraocular lens implantation. Surgical complications as well as adverse events (AEs) during 12 months of follow-up were recorded. At each follow-up visit, a complete ophthalmic examination, including visual acuity, IOP, slit lamp examination, and dilated funduscopy as well as comparative measurements between Goldmann applanation tonometry and the EYEMATE-IO implant were performed. The EYEMATE-IO implant was successfully implanted in 22 patients with few surgical complications and no unexpected device-related AEs. All ocular AEs resolved quickly under appropriate treatment. Comparative measurements showed good agreement between EYEMATE-IO and Goldmann applanation tonometry (GAT) with an intraclass correlation coefficient (ICC(3,k)) of 0.783 (95% confidence interval [CI]: 0.743, 0.817). EYEMATE-IO measurements were higher than GAT, with a mean difference of 3.2 mm Hg (95% CI: 2.8, 3.5 mm Hg). The EYEMATE-IO sensor was safely implanted in 22 patients and performed reliably until the end of follow-up. This device allows for continual and long-term measurements of IOP.
1 April 2011 in Journal of Glaucoma
USUrsula Schloetzer-Schrehardt
Ursula Schloetzer-Schrehardt
Uncontrolled glaucoma presents a challenge for the ophthalmic surgeon especially in children and juvenile patients. For many patients who have undergone failed surgical procedures before, episcleral implants remain the last choice. Encapsulated blebs forming over antiglaucoma devices present a complication leading to malfunctioning or even failure with reincrease in intraocular pressure. We report our histopathologic findings of such blebs developing around the Ahmed glaucoma valve (AGV) after a short time period in young patients. Nine young patients (2 to 17 y of age) with otherwise uncontrollable glaucoma were treated with AGV (models FP-7 and FP-8, silicone base plate) by 1 surgeon (H.T.). Four eyes needed surgical revision 2 to 6 months after initial implantation owing to encapsulated bleb development over the valve with total loss of function. The dense capsule around the device was surgically removed and investigated macroscopically, microscopically, and ultrastructurally. The cystic wall of these encapsulated blebs had an overall thickness of 1.5 to 2 mm. Macroscopically, the tissue was split into 2 layers. Histopathologically, the smooth inner surface (facing the base plate of the AGV) consisted of compressed collagen fibers with signs of elastoid degeneration and with formation of a pseudoendothelium toward the base plate. There was a pronounced transformation of fibroblasts into myofibroblasts in this inner layer. The outer area was highly vascularized. In these vessels electron microscopy revealed thrombosis. Inflammatory responses were nearly absent in all areas of the excised material. Intraocular pressure could be controlled by removal of the encapsulated blebs in all 4 cases. Encapsulation of the AGV is an early complication in young patients, leading to inhibition of fluid exchange and failure of the procedure. The valve mechanism is blocked by contracted scar tissue, but the device itself is not affected by the encapsulation. Surgical excision of the capsule immediately leads to an aqueous flow and drop of intraocular pressure.
1 October 2012 in Investigative Ophthalmology & Visual Science
Purpose. Endothelin-1 (ET-1) has been found in elevated concentrations in the aqueous humor of glaucoma patients. Indirect evidence from animal studies suggests that ET-1 might directly influence intraocular pressure (IOP). The aim of this study was to determine whether ET-1 concentrations in aqueous humor of cataract and glaucoma patients correlate with IOP. Methods. Aqueous humor and blood samples from patients with either cataract (control, n = 38), primary open angle glaucoma (POAG, n = 35), or pseudoexfoliation glaucoma (PEXG, n = 21), without other ocular or systemic disease, were collected during routine cataract surgery or trabeculectomy. ET-1 concentration was determined by an ET-1 ELISA kit. IOP was measured preoperatively by standard Goldmann applanation tonometry. All statistical analysis was performed using commercial predictive analytics software. Results. Both IOP and ET-1 concentration in aqueous humor were significantly increased in POAG (23.4 ± 6.8 mm Hg, 5.9 ± 2.9 pg/mL) and PEXG (24.3 ± 8.8 mm Hg, 7.7 ± 2.1 pg/mL) compared with control (15.0 ± 2.9 mm Hg, 4.3 ± 2.4 pg/mL). No difference was detected for plasma ET-1 concentrations. IOP and ET-1 in the aqueous humor were significantly correlated (R = 0.394, R2 = 0.155, P < 0.001), although no correlation was found between IOP and ET-1 in blood plasma or between ET-1 in aqueous humor and ET-1 in plasma. Conclusions. In this study, a small but highly significant correlation between IOP and the ET-1 concentration in the aqueous humor was found. Although no causative relationship can be deduced from this, ocular ET-1 effects on IOP control may merit further investigation.
1 June 2005 in Experimental Eye Research
1 August 2010 in Investigative Ophthalmology & Visual Science
Purpose.: This study was performed to investigate the surface topography of different glaucoma drainage devices and to determine the effects of surface roughness on cell adhesion of cultured human tenon fibroblasts. Methods.: The surface topography of four widely used devices (Ahmed FP7 and Ahmed S-2; New World Medical, Inc., Rancho Cucamonga, CA; Baerveldt BG101-350; Advanced Medical Optics, Irvine, CA; and Molteno S1; Molteno Ophthalmic Ltd., Dunedin, New Zealand) was investigated by scanning electron microscopy, and roughness was quantified by white-light confocal microscopy. Cells were grown for 72 hours on the surfaces of implants affixed to standard culture dishes. The cells were labeled with a fluorescent dye and detected by confocal laser scanning microscopy, while simultaneously imaging the surface reflectance. Collagen adsorption was quantified immunologically by using fluorescent beads coupled to a secondary antibody. Results.: The root-mean-square roughness was 1.5 ± 0.1 μm (mean ± SE) for the silicone Ahmed model FP7 and 1.3 ± 0.1 μm for the Ahmed with polypropylene base plate Ahmed model S-2. The Baerveldt was substantially smoother, with a mean roughness of 0.1 ± 0.01 μm. The Molteno was the smoothest of all devices (0.07 ± 0.01 μm). Cell adhesion was most prevalent on base plates with higher surface roughness, markedly less pronounced on the smoother base plates, and independent of collagen adsorption. Conclusions.: The most frequently implanted glaucoma drainage devices are of markedly different surface topography. Surface roughness appears to correlate with tenon fibroblast adhesion in vitro and also with the rate of occurrence of postimplantation hypertensive phase and failure due to fibrous encapsulation. Surface roughness may thus play a role in triggering excessive fibrovascular reactions. Smoother base plate surfaces may enhance the success rates of these devices.
1 May 2005 in Experimental Eye Research