Lower-extremity prostheses have evolved through mechanical redesigns that prioritize improved cyclic locomotion. However, this limited approach to limb restoration has precluded necessary progress toward recovering the versatile acyclic movements that constitute the remainder of human athleticism. We present an osseointegrated mechanoneural prosthesis that incorporates modified hard and soft tissues along with permanently implanted hardware in a neuroembodied design. We developed a biomimetic coupling between neuromuscular signaling and joint movement that exceeds the versatility of established control methods, which depend upon conventional amputation musculature and surface electromyography. Our findings also reveal that superior residual neuromuscular function can enable prosthetic movement speeds surpassing that of intact physiology. Anatomical prosthetic integration may be necessary for meeting, and possibly exceeding, the movement capabilities of an intact limb.
17 June 2022 in IEEE Robotics and Automation Letters
The ideal neuroprosthetic control paradigm minimizes disparities in dynamic performance and subjective embodiment between artificial and intact physiology. In this letter, we address the former by introducing the Activation Mapping paradigm, a cascaded optimization procedure that enables a subject with unilateral transtibial amputation to neurally modulate the torque developed during prosthetic ankle plantarflexion. Specifically, in the first stage, the optimization procedure develops a digital locomotor clone that recovers symmetric gait dynamics for the hypothetical subject prior to amputation. In the second stage, the resultant ankle torque-angle trajectory serves as a reference to optimize over the morphological parameters of a neuromuscular ankle model. The optimized model contains a single agonist-antagonist muscle pair driven by a recording of the subject’s within-socket walking electromyograms that reproduces the reference ankle dynamics. In this manner, the subject’s natural residual muscular activations are mapped to their idealized gait dynamics to form a one degree-of-freedom neuromuscular ankle controller. The subsequent implementation of the activation map on a powered ankle prosthesis enables the subject to not only generate physiological ankle dynamics to increase their self-selected walking speed from 1.22 m/s to 1.33 m/s, but also to volitionally perform bilaterally symmetric standing calf raises while balancing for at least 2.0 seconds.
Powered ankle prostheses have been proven to improve the walking economy of people with transtibial amputation. All commercial powered ankle prostheses that are currently available can only perform one-degree-of-freedom motion in a limited range. However, studies have shown that the frontal plane motion during ambulation is associated with balancing. In addition, as more advanced neural interfaces have become available for people with amputation, it is possible to fully recover ankle function by combining neural signals and a robotic ankle. Accordingly, there is a need for a powered ankle prosthesis that can have active control on not only plantarflexion and dorsiflexion but also eversion and inversion. We designed, built, and evaluated a two-degree-of-freedom (2-DoF) powered ankle–foot prosthesis that is untethered and can support level-ground walking. Benchtop tests were conducted to characterize the dynamics of the system. Walking trials were performed with a 77 kg subject that has unilateral transtibial amputation to evaluate system performance under realistic conditions. Benchtop tests demonstrated a step response rise time of less than 50 milliseconds for a torque of 40 N·m on each actuator. The closed-loop torque bandwidth of the actuator is 9.74 Hz. Walking trials demonstrated torque tracking errors (root mean square) of less than 7 N·m. These results suggested that the device can perform adequate torque control and support level-ground walking. This prosthesis can serve as a platform for studying biomechanics related to balance and has the possibility of further recovering the biological function of the ankle–subtalar–foot complex beyond the existing powered ankles.
17 February 2021 in Journal of NeuroEngineering and Rehabilitation
Background: Neuroprosthetic devices controlled by persons with standard limb amputation often lack the dexterity of the physiological limb due to limitations of both the user’s ability to output accurate control signals and the control system’s ability to formulate dynamic trajectories from those signals. To restore full limb functionality to persons with amputation, it is necessary to first deduce and quantify the motor performance of the missing limbs, then meet these performance requirements through direct, volitional control of neuroprosthetic devices.Methods: We develop a neuromuscular modeling and optimization paradigm for the agonist-antagonist myoneural interface, a novel tissue architecture and neural interface for the control of myoelectric prostheses, that enables it to generate virtual joint trajectories coordinated with an intact biological joint at full physiologically-relevant movement bandwidth. In this investigation, a baseline of performance is first established in a population of non-amputee control subjects ( $$n = 8$$ ). Then, a neuromuscular modeling and optimization technique is advanced that allows unilateral AMI amputation subjects ( $$n = 5$$ ) and standard amputation subjects ( $$n = 4$$ ) to generate virtual subtalar prosthetic joint kinematics using measured surface electromyography (sEMG) signals generated by musculature within the affected leg residuum.Results: Using their optimized neuromuscular subtalar models under blindfolded conditions with only proprioceptive feedback, AMI amputation subjects demonstrate bilateral subtalar coordination accuracy not significantly different from that of the non-amputee control group (Kolmogorov-Smirnov test, $$P \ge 0.052$$ ) while standard amputation subjects demonstrate significantly poorer performance (Kolmogorov-Smirnov test, $$P < 0.001$$ ).Conclusions: These results suggest that the absence of an intact biological joint does not necessarily remove the ability to produce neurophysical signals with sufficient information to reconstruct physiological movements. Further, the seamless manner in which virtual and intact biological joints are shown to coordinate reinforces the theory that desired movement trajectories are mentally formulated in an abstract task space which does not depend on physical limb configurations.
Powered ankle prostheses have been proven to improve the walking economy of people with transtibial amputation. All commercial powered ankle prostheses that are currently available can only perform one-degree-of-freedom motion in a limited range. However, studies have shown that the frontal plane motion during ambulation is associated with balancing. In addition, as more advanced neural interfaces have become available for people with amputation, it is possible to fully recover ankle function by combining neural signals and a robotic ankle. Accordingly, there is a need for a powered ankle prosthesis that can have active control on not only plantarflexion and dorsiflexion but also eversion and inversion. We designed, built, and evaluated a two-degree-of-freedom (2-DoF) powered ankle-foot prosthesis that is untethered and can support level-ground walking. Benchtop tests were conducted to characterize the dynamics of the system. Walking trials were performed with a 77 kg subject that has unilateral transtibial amputation to evaluate system performance under realistic conditions. Benchtop tests demonstrated a step response rise time of less than 50 milliseconds for a torque of 40 N·m on each actuator. The closed-loop torque bandwidth of the actuator is 9.74 Hz. Walking trials demonstrated torque tracking errors (root mean square) of less than 7 N·m. These results suggested that the device can perform adequate torque control and support level-ground walking. This prosthesis can serve as a platform for studying biomechanics related to balance and has the possibility of further recovering the biological function of the ankle-subtalar-foot complex beyond the existing powered ankles.