21 August 2019 in IEEE Transactions on Transportation Electrification
Electric vehicles (EVs) can behave as distributed energy storage devices for providing on-demand smart grid support service, that is an emerging Vehicle-to-Grid (V2G) technology. A high-performance and easy-implementation current control strategy for V2G Three-phase four-leg inverter with LCL filter is proposed. It consists of a deadbeat (DB) controller and a paralleled repetitive controller (RC). The DB controller is based on weighted average inductor current (WAIC) scheme, which simplifies the third-order LCL filter to be an equivalent 1st order L filter. The stability of the DB controlled inverter with the unmodelled system time delay is analyzed. DB controller is of very fast response and easy implementation, but is not immune to system time delay and various uncertainties. To overcome the disadvantages, a plug-in RC is added to reinforce the DB controller to remove harmonic distortion from the feed-in current in the presence of parameter uncertainties. A lab prototype of 10kW grid-connected three-phase four-leg inverter has been built up to validate the proposed current control strategy. The simulations and experiments are provided to demonstrate the validity of the proposed control strategy.
2 March 2021 in IEEE Transactions on Transportation Electrification
Three-phase four-leg inverters with an LCL filter are employed as onboard vehicle to grid (V2G) inverters due to their advanced features—high utilization of the dc bus voltage, counteraction of unbalanced voltages, and so on. Repetitive control (RC) can exactly track periodic signals with known frequency, which offers a simple high-accuracy current tracking and harmonic suppression solution for three-phase four-leg inverters. However, the conventional RC (CRC) offers slow dynamic responses due to the embedded delay element, and grid frequency fluctuation would cause significant performance degradation of CRC controllers in V2G applications. Moreover, the three-order LCL filter often causes complexity in developing good performance feedback control schemes for the inverters, especially for complex three-phase four-leg ones. To address these problems, an easy-for-implementation hybrid control scheme that combines a frequency-adaptive RC (FARC) controller with a deadbeat (DB) controller is proposed to obtain fast and accurate control of feed-in grid current for the onboard three-phase four-leg V2G inverters with an LCL filter in the presence of grid frequency variation and load changes. The fast-response DB control scheme is based on a simplified first-order model of an LCL filter. The FARC controller is immune to grid frequency fluctuation. Simulations and experiments have been done to prove that the DB plus FARC control strategy can provide an excellent current control solution for the three-phase four-leg V2G inverters.