Dongsheng Yang

Dongsheng Yang

Auto-generated profile, based on publicly available information

Dongsheng Yang

Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, AP, The Netherlands

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HWHeng Wu
Heng Wu
XRXinbo Ruan
Xinbo Ruan
DYDongsheng Yang
Dongsheng Yang
XCXinran Chen
Xinran Chen
WZWenxin Zhao
Wenxin Zhao
QZQing-Chang Zhong
Qing-Chang Zhong
The concept of the virtual synchronous generator (VSG) is emerging as an attractive solution for controlling the grid-connected inverter when the renewable energy has a high penetration level into the grid. This paper focuses on the small-signal modeling and parameters design of the power loop of the VSG, and points out that the bandwidth of the power loop should be far less than twice the line frequency for the purpose of avoiding the VSG output voltage to be severely distorted. Consequently, the line-frequency-averaged small-signal model of the VSG is derived for system analysis and parameters design. Based on the model, the decoupling conditions between the active power loops (APLs) and the reactive power loops (RPLs) of the VSG are given. Finally, a step-by-step parameters design method is proposed to facilitate the design of the control parameters of the VSG. A 10-kVA prototype is built and tested in the laboratory, and the experimental results are given to verify the effectiveness of the theoretical analysis and the proposed parameters design method.

11 May 2017 in Proceedings of the IEEE
Verified
Journal Article
Open access
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
YYYongheng Yang
Yongheng Yang
DYDongsheng Yang
Dongsheng Yang
XWXiongfei Wang
Xiongfei Wang
Continuously expanding deployments of distributed power-generation systems (DPGSs) are transforming the conventional centralized power grid into a mixed distributed electrical network. The modern power grid requires flexible energy utilization but presents challenges in the case of a high penetration degree of renewable energy, among which wind and solar photovoltaics are typical sources. The integration level of the DPGS into the grid plays a critical role in developing sustainable and resilient power systems, especially with highly intermittent renewable energy resources. To address the challenging issues and, more importantly, to leverage the energy generation, stringent demands from both utility operators and consumers have been imposed on the DPGS. Furthermore, as the core of energy conversion, numerous power electronic converters employing advanced control techniques have been developed for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS are discussed.

1 November 2014 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DYDongsheng Yang
Dongsheng Yang
XRXinbo Ruan
Xinbo Ruan
HWHeng Wu
Heng Wu
The current-controlled grid-connected inverter with LCL filter is widely used in the distributed generation system (DGS), due to its fast dynamic response and better power quality features. However, with the increase of power injected into the grid, control performances of the inverter will be significantly influenced by the nonideal grid conditions. Specifically, the possible wide variation of the grid impedance challenges the system stability. Meanwhile, background harmonics of the grid can greatly distort the injected current. Therefore, the control of the inverter should be designed with strong stability-robustness and high harmonic-rejection-ability, both of which correlate closely with the inverter output impedance. However, it is difficult to shape the output impedance into the one with a desirable characteristic simply by adjusting the current loop gain. In this paper, an impedance shaping method is proposed with virtual impedances, and the current control loop can be designed independently. The implementation and parameter design of the virtual impedances are studied under the practical considerations. With this proposed method, the grid-connected inverter can work stably over a wide range of the typical inductive-resistive grid impedance and exhibit strong rejection ability of grid-voltage harmonics. Experimental results from a 6-kW single-phase grid-connected inverter confirm the effectiveness of the proposed method.

5 April 2010 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYan Li
Yan Li
XRXinbo Ruan
Xinbo Ruan
DYDongsheng Yang
Dongsheng Yang
FLFuxin Liu
Fuxin Liu
CTChi K. Tse
Chi K. Tse
Hybrid power systems continuously deliver power to the load from several renewable energy sources. For such systems, the use of a multiple-input converter (MIC) has the advantage of simpler circuit structure and lower cost, compared to the use of several single-input converters. By decomposing converters into basic cells, namely, pulsating source cells and output filters, a set of basic rules for generating multiple-input converter topologies is proposed. Specifically, two families of multiple-input converters are systematically generated. In the first family of MICs, all the input sources can power the load simultaneously or individually. In the second family, only one power source is allowed to transfer energy to the load at a time. Furthermore, some isolated MICs are simplified for reducing the complexity of the circuit configuration.

3 June 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DYDongsheng Yang
Dongsheng Yang
XRXinbo Ruan
Xinbo Ruan
HWHeng Wu
Heng Wu
Due to the higher attenuation of switching frequency current harmonics, the LCL filter has been widely used in grid-connected inverters. To deal with the resonance of the LCL filter, the capacitor current is usually fed back to damp the resonance actively. However, the computation and pulsewidth modulation (PWM) delays in the digital control system have a significant influence on the active damping method, resulting in poor system robustness. Meanwhile, these delays also reduce the control bandwidth greatly and thus impose a severe limitation on the low-frequency gains. In this paper, a real-time computation method with dual sampling mode is proposed to remove the computation delay from the inner active damping loop and the outer grid-current control loop simultaneously; thus, the system robustness and the control performance can be greatly improved. Moreover, the time duration between the sampling instant and the switching transition of the inverter bridge is extended by the proposed method, which effectively prevents the switching noise distorting the sampled signals. Therefore, the noise immunity of the inverter is also improved greatly. Experimental results from a 6-kW LCL-type single-phase grid-connected inverter confirm the theoretical expectations and the effectiveness of the proposed method.

17 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DYDongsheng Yang
Dongsheng Yang
XWXiongfei Wang
Xiongfei Wang
FLFangcheng Liu
Fangcheng Liu
KXKai Xin
Kai Xin
YLYunfeng Liu
Yunfeng Liu
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg