Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
Auto-generated profile, based on publicly available information
Bethelhem Abera
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
Wastewater surveillance (WWS) at healthcare facilities is a nascent field with knowledge gaps in the feasibility of conducting such surveillance at this specialized facility type, and for how to best implement and interpret wastewater (WW) data. WWS was piloted at skilled nursing facilities, including conducting tracer studies, optimization of a low-flow strainer for autosampler WW collection, and preliminary testing of a WW access survey. An expanded WW access survey with collaboration from additional partners was distributed to 16 post-acute/long-term care facilities. The lessons learned obtained through the pilot ‘use cases’ demonstrated minimal clogging and consistent collection of WW using a low-flow strainer (±0.36 L) and tracer studies highlighted the importance to confirm facility effluent source with an average visual dye detection between 1.5 and 2.5 min from the toilet flush. The expanded WW access survey assessed the feasibility of WWS regarding physical onsite manhole access, safety aspects, effluent flow, and other factors, where 75% (12 of 16) of surveyed facilities demonstrated feasibility. Healthcare facility-level WWS includes specialized methodological approaches prior to implementation to achieve the intended public health impact. These considerations support the continued overall goal of detecting emerging biological public health threats at healthcare facilities using WWS.
A pictographic representation of the text abstract showing wastewater and epidemiologic data flow and data integration. To understand the utility of healthcare facility-level wastewater surveillance (WWS) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), it is important to correlate wastewater SARS-CoV-2 RNA detection with the number of clinical infections. WWS for SARS-CoV-2 was performed at three skilled nursing facilities (SNFs) over 25 weeks. Electronegative membrane filtration (enMF) and Nanotrap® Magnetic Virus Particles (NP) virus concentration methods were compared. Extracts were tested by droplet digital polymerase chain reaction. Spearman's correlations (ρ) between wastewater virus RNA concentrations and infection counts were calculated. From split wastewater samples, enMF recovered higher SARS-CoV-2 RNA concentrations than NP. Combining data from all facilities, the median concentrations were 53.0 versus 38.6 gc/100 mL for enMF and NP, respectively (p = 0.001). Using enMF, correlations were moderate to strong at SNF A (ρ ranged 0.67–0.86, all p-values <0.001). Weak to moderate correlations may reflect the sampled manhole not representing the entire facility (SNF B, ρ ranged 0.47–0.72, p-values ranged <0.001–0.12) and longitudinal data gaps from summer heat and equipment maintenance (SNF C, ρ ranged 0.14–0.59, p-values ranged<0.01 to 0.52). WWS can be a valuable tool for tracking dynamics of SARS-CoV-2 infections in healthcare facilities.