1 December 2010 in Journal of Composites for Construction
Increasing interest in the use of fiber-reinforced polymer (FRP) reinforcement for reinforced concrete structures has made it clear that insufficient information about the shear performance of such members is currently available to practicing engineers. This paper summarizes the results of 11 large shear tests of reinforced concrete beams with glass FRP (GFRP) longitudinal reinforcement and with or without GFRP stirrups. Test variables were the member depth, the member flexural reinforcement ratio, and the amount of shear reinforcement provided. Results showed that the equations of the Canadian CSA shear provisions provide conservative estimates of the shear strength of FRP-reinforced members. Recommendations are given along with a worked example on how to apply these provisions including to members with FRP stirrups. It was found that members with multiple layers of longitudinal bars appear to perform better than those with a single layer of longitudinal reinforcing bars. Overall, it was concluded that t...
1 July 2006 in ACI Structural Journal
1 June 1999 in Cement and Concrete Research
1 May 2006 in Canadian Journal of Civil Engineering
This paper describes the development of the 2004 Canadian Standards Association (CSA) A23.3 shear design provisions for reinforced and prestressed concrete structures. These methods are similar to the 1994 standard in providing a simplified and general shear design method. They differ from previous standards by providing a direct link between these two methods and simple equations for the calculation of β and θ used in the general method rather than providing these values in a table. The paper explains the basic assumptions behind the new shear provisions, provides a derivation of the new equations, and compares designs made with the new equations to designs obtained from previous standards. In general, the new shear provisions require slightly less shear reinforcement than that required by the previous standard. The new general method is significantly easier to use, particularly with spreadsheets.Key words: shear, building codes, reinforced concrete, size effect, structural design.
1 April 2008 in Journal of Composites for Construction
For members with no transverse reinforcement, numerous models have been proposed for determining shear capacity, most often based on a statistical curve fit to experimental beam test results. The shear provisions of the Canadian code (CSA) for steel-reinforced concrete, by contrast, are based on a theoretical model, the modified compression field theory. This paper demonstrates that the CSA shear provisions for steel-reinforced members can be safely applied to members with internal fiber-reinforced polymer (FRP) bars by adjusting the term Es As in the method to Er Ar . A database of 146 shear failures of specimens reinforced with carbon, glass, or aramid FRP or steel is presented and gives an average test to predicted ratio of 1.38 with a coefficient of variation (COV) of 17.2%. The CSA code equations were optimized for the typical strain range of steel-reinforced concrete and when an equation appropriate for the wider range of strains associated with FRP is used, then a better statistical result can be a...
1 September 2014 in ACI Structural Journal