A. J. H. Donne

A. J. H. Donne

Auto-generated profile, based on publicly available information

A. J. H. Donne

FOM-Institute for Plasma Physics Rijnhuizen P.O. Box 1207, 3430 BE Nieuwegein, The Netherlands, Tel. +49 2461 61 3655 / +31 653 798 329, Fax +49 2461 61 4038

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2003 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HPH. Park
H. Park
CCC. C. Chang
C. C. Chang
BDB. H. Deng
B. H. Deng
CDC. W. Domier
C. W. Domier
ADA. J. H. Donné
A. J. H. Donné
WZW-K. Zhang
W-K. Zhang
Significant advances in microwave and millimeter wave technology over the past decade have enabled the development of a new generation of imaging diagnostics for current and envisioned magnetic fusion devices. Prominent among these are microwave electron cyclotron emission imaging, microwave phase imaging interferometers, imaging microwave scattering, and microwave imaging reflectometer systems for imaging Te and ne fluctuations (both turbulent and coherent) and profiles (including transport barriers) on toroidal devices such as tokamaks, spherical tori, and stellarators. The diagnostic technology is reviewed, and typical diagnostic systems are analyzed. Representative experimental results obtained with these novel diagnostic systems are also presented.

1 October 2004 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HPH. Park
H. Park
EME. Mazzucato
E. Mazzucato
TMT. Munsat
T. Munsat
CDC. W. Domier
C. W. Domier
MJM. Johnson
M. Johnson
MPM. J. van de Pol
M. J. van de Pol
Diagnostic systems for fluctuation measurements in plasmas are, of necessity, evolving from simple one-dimensional (1D) systems to multidimensional systems due to the complexity of the magnetohydrodynamics (MHD) and turbulence physics of plasmas as illustrated by advanced numerical simulations. Using the recent significant advancements in millimeter wave imaging technology, microwave imaging reflectometry (MIR) and electron cyclotron emission imaging (ECEI), simultaneously measuring density and temperature fluctuations, have been developed for Toroidal EXperiment for Technology Oriented Research (TEXTOR). The MIR system was installed on Textor and the experiment was performed in September, 2003. Subsequent MIR campaigns have yielded poloidally resolved spectra and assessments of poloidal velocity. The 2D ECE imaging system (with a total of 128 channels), installed on TEXTOR in December, 2003, successfully captured the first true 2D images of Te fluctuations of m=1 oscillations (“sawteeth”) near the q∼1 surface.

1 November 2003 in Nuclear Fusion
Verified
Journal Article
Closed access
EWE Westerhof
E Westerhof
JHJ.A Hoekzema
J.A Hoekzema
GHG.M.D Hogeweij
G.M.D Hogeweij
RJR.J.E Jaspers
R.J.E Jaspers
FSF.C Schüller
F.C Schüller
TTTec Team
Tec Team
The 110 GHz and the new 140 GHz gyrotron systems for electron cyclotron resonance heating (ECRH) and ECCD on TEXTOR are described and results of ECRH experiments with the 110 GHz system are reported. Central ECRH on Ohmic plasmas shows the presence of an internal electron transport barrier near q = 1. This is confirmed by modulated ECRH experiments. A central barrier is also indicated by ECRH in radiatively improved (RI) mode discharges and up to two barriers are seen with ECRH during the current ramp phase. ECRH control of sawteeth is reported for both Ohmic and RI mode target plasmas.

1 May 2001 in Physics of Plasmas
Verified
Journal Article
Closed access
BDB. H. Deng
B. H. Deng
CDC. W. Domier
C. W. Domier
NLN. C. Luhmann
N. C. Luhmann
DBD. L. Brower
D. L. Brower
ADA. J. H. Donné
A. J. H. Donné
MPM. J. van de Pol
M. J. van de Pol
A novel high resolution, two-dimensional (2-D) plasma diagnostic technique, electron cyclotron emission imaging, is reviewed. Its high spatial and temporal resolution is illustrated from the measurement of small-scale structure in Te profiles. Its 2-D measurement capability has been utilized to “visualize” plasma turbulence structures in the Rijnhuizen Tokamak Project (RTP) [Hogeweij et al., Phys. Scr. 51, 627 (1995)]. Comprehensive experimental results of Te fluctuations in RTP are presented. Possible correlation between the characteristics of the measured Te fluctuations and ηi mode theory predictions are indicated, which calls for further theoretical and experimental investigation. Future diagnostic developments are also discussed.

3 March 2005 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
TTTextor Team
Textor Team
ADA. J. H. Donné
A. J. H. Donné
JGJ. C. van Gorkom
J. C. van Gorkom
VUV. S. Udintsev
V. S. Udintsev
CDC. W. Domier
C. W. Domier
FSF. C. Schüller
F. C. Schüller
Small-scale structures with high poloidal mode numbers (m=10–20) have been observed in the TEXTOR tokamak plasma with pulsed radar reflectometry and an electron cyclotron emission diagnostic, in conjunction with large 2/1 and 1/1 islands. The small islands have a peaked density profile, similar to that of the simultaneously observed large-scale 2/1 islands. This together with the observation that high-frequency density and temperature fluctuations are very pronounced near the X points of the large islands hints to a strongly perturbed magnetic topology around the X points.

1 October 2004 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JWJ. Wang
J. Wang
CDC. W. Domier
C. W. Domier
ZXZ. G. Xia
Z. G. Xia
YLY. Liang
Y. Liang
NLN. C. Luhmann
N. C. Luhmann
ADA. J. H. Donné
A. J. H. Donné
A two-dimensional electron cyclotron emission imaging (ECEI) diagnostic has been developed in which broad bandwidth radiation is collected by a vertically aligned mixer array and separated by frequency band. Using a 16 element array, and an 8 band receiver attached to each array element, time-resolved 16×8 images of electron temperature profiles and fluctuations of the TEXTOR plasma are acquired with vertical and horizontal channel spacings of 11 and 8 mm , and spot sizes of 13 and 9 mm , respectively. The system is wideband tunable from 95 to 130 GHz , and the focus location may be shifted horizontally via translation of one of the optical imaging elements. System design and laboratory testing details of the ECE Imaging optics and multichannel wideband electronics are presented, together with TEXTOR plasma data.