Rabah Touaibi

Rabah Touaibi

Auto-generated profile, based on publicly available information

Rabah Touaibi

Laboratory of Industrial Fluid, Measurements, and Application (FIMA) University of Khemis Miliana Khemis Miliana Algeria

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Emerging Science Journal
Verified
Journal Article
Open access
PDF file
RTRabah Touaibi
Rabah Touaibi
HKHasan Koten
Hasan Koten
OBOzlem Boydak
Ozlem Boydak
This work is an energy study of an organic Rankine cycle (ORC) for the recovery of thermal energy by comparing three organic fluids. This cycle is considered to be a promising cycle for the conversion of heat into mechanical energy suitable for low temperature heat sources; it uses more volatile organic fluids than water, which generally has high molecular weights, thus allowing operating pressures at temperatures lower than those of the traditional Rankine cycle. A thermodynamic model was developed using the Engineering Equation Solver (EES) software to determine its performance using different working fluids (toluene, R245fa and R123) under the same operating conditions, taking into account the effect of certain operating parameters and the selection of organic fluids on cycle performance. The results obtained show that the toluene organic fluid has the best thermal efficiency of the cycle compared to the other fluids; 14.38% for toluene, 13.68% for R123 and 13.19 for R245fa.

26 September 2021 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
RTRabah Touaibi
Rabah Touaibi
HKHasan Koten
Hasan Koten
An energy analysis study carried out on a vapor compression refrigeration cycle using refrigerants with low global warming potential (GWP) of the Hydro-Fluoro-Olefin (HFO) type, in particular R1234yf and R1234ze fluids to replace HFC refrigerants . Computer code was developed using software for solving engineering equations to calculate performance parameters; for this, three HFC type fluids (R134a, R404A and R410A) were selected for a comparative study. The results showed that R1234ze is the best refrigerant among those selected for the mechanical vapor compression refrigeration cycle. The thermodynamic analysis showed the effect of the evaporator temperature (-22 °C to 10 °C) and the condenser temperature (30 °C to 50 °C) on the steam cycle performance. Compression refrigeration, including the coefficient of performance. The results showed that the HFO-R1234ze with low GWP gives the best coefficient of performance of 3.14 close to that of the R134a fluid (3.17). In addition, R1234ze is considered an alternative fluid to R134a for their ecological properties.

1 January 2013 in International Journal of Exergy
Verified
Journal Article
Closed access
RTRabah Touaibi
Rabah Touaibi
MFMichel Feidt
Michel Feidt
EVElena Eugenia Vasilescu
Elena Eugenia Vasilescu
MAMiloud Tahar Abbes
Miloud Tahar Abbes
This paper presents the energy and exergy analysis of single-effect water-lithium bromide absorption cooling system driven by the heat supplied by a field of solar thermal collectors with a cooling capacity of 10 kW. The work is devoted to the study, the evaluation and distribution of the destroyed exergy for each component constituting this kind of system. The thermodynamic models have been derived using the first and second laws of thermodynamics. These models are employed in a computer program using the engineering equation solver (EES) software to perform the calculations and a sensitivity analysis to parameters is also presented. The results indicate that the contribution of some components to the overall exergy loss is very important. Exergy analysis also illustrates that the distribution of the destroyed exergy in the system between components depends strongly on the working temperatures.

1 March 2020 in Hittite Journal of Science and Engineering
Verified
Journal Article
Open access
PDF file
RTRabah Touaibi
Rabah Touaibi
Hasan KotenHasan Koten
Hasan Koten
OBOzlem Boydak
Ozlem Boydak
This study presents an energy study of an Organic Rankine Cycle (ORC) by comparing three organic fluids. The latter is considered as a promising cycle for the conversion of heat into mechanical energy adapted to low-temperature heat sources; it uses more volatile organic fluids than water, which generally has high molecular weights, thus allowing operating pressures at temperatures lower than those of the traditional Rankine cycle. This study devoted to the energy analysis of the ORC cycle, taking into account the effect of the operating temperatures and the choice of the organic fluid on the cycle performance. The utilized three fluids were Toluene, R245fa and R123. The results obtained show that the Toluene organic fluid has the best energy efficiency of the cycle with 7.45%. Keywords: ORC cycle, Energy Analysis, Organic Fluids, Performance, Toluene. DOI: 10.17350/HJSE19030000170 Full Text:

1 July 2021 in Journal of Thermal Engineering
Verified
Journal Article
Closed access
PDF file
TRTouaibi Rabah
Touaibi Rabah
Hasan KotenHasan Koten
Hasan Koten
BFBoudjema Fadhila
Boudjema Fadhila
SSSelmane Salma
Selmane Salma
MHMohamed HEMIS
Mohamed HEMIS
In this paper, a new combined system is proposed for recovering thermal energy at medium temperature using a cascade organic Rankine cycle to feed a cascade refrigeration cycle. Energy and exergy analysis is applied to the combined system to determine its performance using different working fluids under the same operating conditions taking into account the effect of some operating parameters and the selection of organic fluids on cycle performance. The pair of organic fluid (Toluene/R245fa) used for the cascade organic Rankine cycle and the pairs (R717/R744, R717/R23, R134a/R23) used for the cascade refrigeration cycles. The results show that the combined system function with the couple (R717/R23) for cascade refrigeration cycle gives better exergy efficiency 50.03% compared to other couples, 49.57% for the couple (R717/R744), and 48.01% for the couple (R134a/R23). The thermodynamic evaluation shows that the operating temperatures, such as the cascade organic Rankine cycle evaporation temperature and the cascade refrigeration cycle evaporation temperature influence the performance of the combined system.

17 June 2023 in Mechanics
Verified
Journal Article
Open access
PDF file
RTRabah Touaibi
Rabah Touaibi
Hasan KotenHasan Koten
Hasan Koten
This study conducts a parametric study based on the energy and exergy analysis of a combined cycle composed of an organic Rankine and dual evaporator cooling cycles. The mechanical power supplied provides the mechanical compression refrigeration cycle with two evaporators. The influence of operating temperature, including the impact of the evaporator temperature of the organic Rankine cycle and the effect of dual evaporator cooling cycle evaporator temperature, were investigated; in this case, three organic fluids were employed such as R134a, R290, and R600. The results indicate that using R600 as the working fluid for both cycles enhance the system performance, and the energy efficiency of the combined system grows from 27.10 % to 40.22 %.The performance factor of the dual evaporator cooling cycle increases from 3.25 to 3.29 for the evaporating temperature of the first evaporator and from 2.07 to 4.28 for the second evaporator. Moreover, it is also noted that the exergy efficiency of the dual evaporator cooling cycle decreased from 40.03 % to 30.18 % for the first evaporator and increased by 32.47 % to 38.82 % for the second evaporator.