Rohan Banerjee

Rohan Banerjee

Auto-generated profile, based on publicly available information

Rohan Banerjee

Tata Consultancy Services

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2017
Verified
Conference Paper
Closed access
SDShreyasi Datta
Shreyasi Datta
CPChetanya Puri
Chetanya Puri
AMAyan Mukherjee
Ayan Mukherjee
RBRohan Banerjee
Rohan Banerjee
ACAnirban Dutta Choudhury
Anirban Dutta Choudhury
SKSundeep Khandelwal
Sundeep Khandelwal

1 August 2014
Verified
Conference Paper
Closed access
ACAnirban Dutta Choudhury
Anirban Dutta Choudhury
RBRohan Banerjee
Rohan Banerjee
ASAniruddha Sinha
Aniruddha Sinha
SKShaswati Kundu
Shaswati Kundu
Simple and non-invasive methods to estimate vital signs are very important for preventive healthcare. In this paper, we present a methodology to estimate Blood Pressure (BP) using Photoplethysmography (PPG). Instead of directly relating systolic and diastolic BP values with PPG features, our proposed methodology initially maps PPG features with some person specific intermediate latent parameters and later derives BP values from them. The 2-Element Windkessel model has been considered in the current context to estimate total peripheral resistance and arterial compliance of a person using PPG features, followed by linear regression for simulating arterial blood pressure. Experimental results, performed on a standard hospital dataset yielded absolute errors of 0.78±13.1 mmHg and 0.59 ± 10.23 mmHg for systolic and diastolic BP values respectively. Results also indicate that the methodology is more robust than the standard methodologies that directly estimate BP values from PPG signal.

1 May 2014
Verified
Conference Paper
Closed access
RBRohan Banerjee
Rohan Banerjee
ASAniruddha Sinha
Aniruddha Sinha
ACAnirban Dutta Choudhury
Anirban Dutta Choudhury
AVAishwarya Visvanathan
Aishwarya Visvanathan
This paper presents a simple method to indirectly estimate the range of certain important electrocardiogram (ECG) parameters using photoplethysmography (PPG). The proposed method, termed as PhotoECG, extracts a set of time and frequency domain features from fingertip PPG signal. A feature selection algorithm utilizing the concept of Maximal Information Coefficient (MIC) is presented to rank the PPG features according to their relevance to create training models for different ECG parameters. The proposed method yields above 90% accuracy in estimating ECG parameters on a benchmark hospital dataset having clean PPG signal. The same method results an average of 80% accuracy on noisy PPG signal captured by iPhone, indicating its feasibility to create phone applications for preventive ECG monitoring at home.

1 May 2019 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
AMAyan Mukherjee
Ayan Mukherjee
ACAnirban Dutta Choudhury
Anirban Dutta Choudhury
SDShreyasi Datta
Shreyasi Datta
CPChetanya Puri
Chetanya Puri
RBRohan Banerjee
Rohan Banerjee
SKSundeep Khandelwal
Sundeep Khandelwal
Objective : Atrial fibrillation (AF) and other types of abnormal heart rhythm are related to multiple fatal cardiovascular diseases that affect the quality of human life. Hence the development of an automated robust method that can reliably detect AF, in addition to other non-sinus and sinus rhythms, would be a valuable addition to medicine. The present study focuses on developing an algorithm for the classification of short, single-lead electrocardiogram (ECG) recordings into normal, AF, other abnormal rhythms and noisy classes. Approach : The proposed classification framework presents a two-layer, three-node architecture comprising binary classifiers. PQRST markers are detected on each ECG recording, followed by noise removal using a spectrogram power based novel adaptive thresholding scheme. Next, a feature pool comprising time, frequency, morphological and statistical domain ECG features is extracted for the classification task. At each node of the classification framework, suitable feature subsets, identified through feature ranking and dimension reduction, are selected for use. Adaptive boosting is selected as the classifier for the present case. The training data comprises 8528 ECG recordings provided under the PhysioNet 2017 Challenge. F1 scores averaged across the three non-noisy classes are taken as the performance metric. Main result : The final five-fold cross-validation score achieved by the proposed framework on the training data has high accuracy with low variance (0.8254 0.0043). Significance : Further, the proposed algorithm has achieved joint first place in the PhysioNet/Computing in Cardiology Challenge 2017 with a score of 0.83 computed on a hidden test dataset.

1 April 2015
Verified
Conference Paper
Closed access
RBRohan Banerjee
Rohan Banerjee
AGAvik Ghose
Avik Ghose
ACAnirban Dutta Choudhury
Anirban Dutta Choudhury
ASAniruddha Sinha
Aniruddha Sinha
APArpan Pal
Arpan Pal
Photoplethysmography (PPG) signals, captured using smart phones are generally noisy in nature. Although they have been successfully used to determine heart rate from frequency domain analysis, further indirect markers like blood pressure (BP) require time domain analysis for which the signal needs to be substantially cleaned. In this paper we propose a methodology to clean such noisy PPG signals. Apart from filtering, the proposed approach reduces the baseline drift of PPG signal to near zero. Furthermore it models each cycle of PPG signal as a sum of 2 Gaussian functions which is a novel contribution of the method. We show that, the noise cleaning effect produces better accuracy and consistency in estimating BP, compared to the state of the art method that uses the 2-element Windkessel model on features derived from raw PPG signal, captured from an Android phone.

1 May 2016
Verified
Conference Paper
Closed access
SDShreyasi Datta
Shreyasi Datta
RBRohan Banerjee
Rohan Banerjee
ACAnirban Dutta Choudhury
Anirban Dutta Choudhury
ASAniruddha Sinha
Aniruddha Sinha
APArpan Pal
Arpan Pal
Non-invasive cuff-less Blood Pressure (BP) estimation from Photoplethysmogram (PPG) is a well known challenge in the field of affordable healthcare. This paper presents a set of improvements over an existing method that estimates BP using 2-element Windkessel model from PPG signal. A noisy PPG corpus is collected using fingertip pulse oximeter, from two different locations in India. Exhaustive pre-processing techniques, such as filtering, baseline and topline correction are performed on the noisy PPG signals, followed by the selection of consistent cycles. Subsequently, the most relevant PPG features and demographic features are selected through Maximal Information Coefficient (MIC) score for learning the latent parameters controlling BP. Experimental results reveal that overall error in estimating BP lies within 10% of a commercially available digital BP monitoring device. Also, use of alternative latent parameters that incorporate the variation in cardiac output, shows a better trend following for abnormally low and high BP.