Leticia Pereira Gonçalves

Leticia Pereira Gonçalves

Auto-generated profile, based on publicly available information

Leticia Pereira Gonçalves

Centro de Diagnóstico por Imagem (CDPI)/DASA, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Radiologia Brasileira
Verified
Journal Article
Open access
PDF file
MCMaria Julia Gregório Calas
Maria Julia Gregório Calas
FPFernanda Philadelpho Arantes Pereira
Fernanda Philadelpho Arantes Pereira
LGLeticia Pereira Gonçalves
Leticia Pereira Gonçalves
FLFlavia Paiva Proença Lobo Lopes
Flavia Paiva Proença Lobo Lopes
Objective: To evaluate the main technical limitations of automated breast ultrasound and to determine the proportion of examinations excluded. Materials and Methods: We evaluated 440 automated breast ultrasound examinations performed, over a 12-month period, by technicians using an established protocol. Results: In five cases (1.1%), the examination was deemed unacceptable for diagnostic purposes, those examinations therefore being excluded. Conclusion: Automated breast ultrasound is expected to overcome some of the major limitations of conventional ultrasound in breast cancer screening. In Brazil, this new method can be accepted for inclusion in routine clinical practice only after its advantages have been validated in the national context.

1 January 2019 in Mastology
Verified
Journal Article
Open access
LGLeticia Pereira Gonçalves
Leticia Pereira Gonçalves
CIClínica de Diagnóstico Por Imagem
Clínica de Diagnóstico Por Imagem
MLMariana Loureiro Lemos
Mariana Loureiro Lemos
MCMaria Julia Gregorio Calas
Maria Julia Gregorio Calas
Introduction: Breast Imaging Reporting and Data System (BI-RADS) classification allows standardization of breast masses findings, with a recommendation for individualized management. Because of their high frequency, masses classified as 3, probably benign, arouse interest in improving their characterization and in establishing the most appropriate behavior. Objective: Firstly, to demonstrate the positive and negative predictive values of the BI-RADS 3 classification of solid masses submitted to percutaneous biopsy by ultrasonography. Secondly, to suggest a different ultrasound follow-up conduct in these findings. Methods: We retrospectively studied 480 BI-RADS 3 masses, submitted to a biopsy under vacuum or core biopsy, with a conclusive histopathological result considered the gold standard. Results: From 480 masses in 396 patients, 473 were benign and 7 malignant. The positive predictive value for malignancy of category 3 masses was 1.5% (7/480), and the negative predictive value was 98.5%. Conclusion: In view of the low probability of cancer, it is recommended the performance of directed ultrasonography (second look) of masses classified as BI-RADS 3 performed by a specialist in breast radiology before the indication of an invasive procedure, what would substantially reduce the number of unnecessary biopsies, patient’s anxiety, as well as costs and possible related complications. This will increase the possibility for the specialist to spend more time on really necessary and targeted examinations, better defining cases of follow-up (annual or biannual) of the indication of investigation in specific cases.