Mark Newpower

Mark Newpower

Auto-generated profile, based on publicly available information

Mark Newpower

Department of Radiation Oncology University of Oklahoma Health Sciences Center Oklahoma City Oklahoma USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
MNMark Newpower
Mark Newpower
DPDarshana Patel
Darshana Patel
LBLawrence Bronk
Lawrence Bronk
FGFada Guan
Fada Guan
PCPankaj Chaudhary
Pankaj Chaudhary
RMRadhe Mohan
Radhe Mohan
We introduce a methodology to calculate the microdosimetric quantity dose-mean lineal energy for input into the microdosimetric kinetic model (MKM) to model the relative biological effectiveness (RBE) of proton irradiation experiments. The data from 7 individual proton RBE experiments were included in this study. In each experiment, the RBE at several points along the Bragg curve was measured. Monte Carlo simulations to calculate the lineal energy probability density function of 172 different proton energies were carried out with use of Geant4 DNA. We calculated the fluence-weighted lineal energy probability density function (fw(y)), based on the proton energy spectra calculated through Monte Carlo at each experimental depth, calculated the dose-mean lineal energy yD¯ for input into the MKM, and then computed the RBE. The radius of the domain (rd) was varied to reach the best agreement between the MKM-predicted RBE and experimental RBE. A generic RBE model as a function of dose-averaged linear energy transfer (LETD) with 1 fitting parameter was presented and fit to the experimental RBE data as well to facilitate a comparison to the MKM. Both the MKM and LETD-based models modeled the RBE from experiments well. Values for rd were similar to those of other cell lines under proton irradiation that were modeled with the MKM. Analysis of the performance of each model revealed that neither model was clearly superior to the other. Our 3 key accomplishments include the following: (1) We developed a method that uses the proton energy spectra and lineal energy distributions of those protons to calculate dose-mean lineal energy. (2) We demonstrated that our application of the MKM provides theoretical validation of proton irradiation experiments that show that RBE is significantly greater than 1.1. (3) We showed that there is no clear evidence that the MKM is better than LETD-based RBE models.

21 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Ramin AbolfathRamin Abolfath
Ramin Abolfath
CPChristopher Peeler
Christopher Peeler
MNMark Newpower
Mark Newpower
LBLawrence Bronk
Lawrence Bronk
DGDavid Grosshans
David Grosshans
RMRadhe Mohan
Radhe Mohan
We introduce an approach for global fitting of the recently published high-throughput and high accuracy clonogenic cell-survival data for therapeutic scanned proton beams. Our fitting procedure accounts for the correlation between the cell-survival, the absorbed (physical) dose and the proton linear energy transfer (LET). The fitting polynomials and constraints have been constructed upon generalization of the microdosimetric kinetic model (gMKM) adapted to account for the low energy and high lineal-energy spectrum of the beam where the current radiobiological models may underestimate the reported relative biological effectiveness (RBE). The parameters (α, β) of the linear-quadratic (LQ) model calculated by the presented method reveal a smooth transition from low to high LETs which is an advantage of the current method over methods previously employed to fit the same clonogenic data. Finally, the presented approach provides insight into underlying microscopic mechanisms which, with future study, may help to elucidate radiobiological responses along the Bragg curve and resolve discrepancies between experimental data and current RBE models.

7 February 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
MNMark A. Newpower
Mark A. Newpower
BCBing‐Hao Chiang
Bing‐Hao Chiang
SASalahuddin Ahmad
Salahuddin Ahmad
YCYong Chen
Yong Chen
The purpose of this work is to assess the robustness of treatment plans when spot delivery errors were predicted with a machine learning (ML) model for intensity modulated proton therapy (IMPT). Over 6000 machine log files from delivered IMPT treatment plans were included in this study. From these log files, over 4.1 106 delivered proton spots were used to train the ML model. The presented model was tested and used to predict the spot position as well as the monitor units (MU) per spot, based on the original planning parameters. Two patient plans (one accelerated partial breast irradiation [APBI] and one ependymoma) were recalculated with the predicted spot position/MUs by the ML model and then were re‐analyzed for robustness. Plans with ML predicted spots were less robust than the original clinical plans. In the APBI plan, dosimetric changes to the left lung and heart were not clinically relevant. In the ependymoma plan, the hot spot in the brainstem decreased and the hot spot in the cervical cord increased. Despite these differences, after robustness analysis, both ML spot delivery error plans resulted in >95% of the CTV receiving >95% of the prescription dose. The presented workflow has the potential benefit of including realistic spots information for plan quality checks in IMPT. This work demonstrates that in the two example plans, the plans were still robust when accounting for spot delivery errors as predicted by the ML model.

1 June 2019 in International Journal of Particle Therapy
Verified
Journal Article
Open access
MNMark Newpower
Mark Newpower
JSJan Schuemann
Jan Schuemann
RMRadhe Mohan
Radhe Mohan
HPHarald Paganetti
Harald Paganetti
UTUwe Titt
Uwe Titt
Purpose: Several Monte Carlo transport codes are available for medical physics users. To ensure confidence in the accuracy of the codes, they must be continually cross-validated. This stud...

7 June 2016 in Medical Physics
Verified
Journal Article
Closed access
MNM Newpower
M Newpower
SGS Ge
S Ge
RMR Mohan
R Mohan

29 May 2014 in Medical Physics
Verified
Journal Article
Closed access
MNM Newpower
M Newpower
SAS Ahmad
S Ahmad
YCY Chen
Y Chen