Matt Trinh

Matt Trinh

Auto-generated profile, based on publicly available information

Matt Trinh

School of Optometry and Vision Science, University of New South Wales, Sydney, Australia

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2023 in Ophthalmology Retina
Verified
Journal Article
Closed access
MTMatt Trinh
Matt Trinh
RCRene Cheung
Rene Cheung
ADAnnita Duong
Annita Duong
LNLisa Nivison-Smith
Lisa Nivison-Smith
ALAngelica Ly
Angelica Ly

18 March 2024 in Eye
Verified
Journal Article
Open access
PDF file
MTMatt Trinh
Matt Trinh
MKMichael Kalloniatis
Michael Kalloniatis
SKSieu K. Khuu
Sieu K. Khuu
LNLisa Nivison-Smith
Lisa Nivison-Smith
Visual fields under mesopic and scotopic lighting are increasingly being used for macular functional assessment. This review evaluates its statistical significance and clinical relevance, and the optimal testing protocol for early/intermediate age-related macular degeneration (AMD). PubMed and Embase were searched from inception to 14/05/2022. All quality assessments were performed according to GRADE guidelines. The primary outcome was global mean sensitivity (MS), further meta-analysed by: AMD classification scheme, device, test pattern, mesopic/scotopic lighting, stimuli size/chromaticity, pupil dilation, testing radius (area), background luminance, adaptation time, AMD severity, reticular pseudodrusen presence, and follow-up visit. From 1489 studies screened, 42 observational study results contributed to the primary meta-analysis. Supported by moderate GRADE certainty of the evidence, global MS was significantly reduced across all devices under mesopic and scotopic lighting with large effect size (−0.9 [−1.04, −0.75] Hedge’s g, P < 0.0001). The device (P < 0.01) and lighting (P < 0.05) used were the only modifiable factors affecting global MS, whereby the mesopic MP-1 and MAIA produced the largest effect sizes and exceeded test-retest variabilities. Global MS was significantly affected by AMD severity (intermediate versus early AMD; −0.58 [−0.88, −0.29] Hedge’s g or −2.55 [3.62, −1.47] MAIA-dB) and at follow-up visit (versus baseline; −0.62 [−0.84, −0.41] Hedge’s g or −1.61[−2.69, −0.54] MAIA-dB). Magnitudes of retinal sensitivity changes in early/intermediate AMD are clinically relevant for the MP-1 and MAIA devices under mesopic lighting within the central 10° radius. Other factors including pupil dilation and dark adaptation did not significantly affect global MS in early/intermediate AMD.

25 June 2025 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
MTMatt Trinh
Matt Trinh
RCRene Cheung
Rene Cheung
JNJudy Nam
Judy Nam
DNDavid Ng
David Ng
LNLisa Nivison‐Smith
Lisa Nivison‐Smith
ALAngelica Ly
Angelica Ly
Purpose: The translation of high‐risk biomarkers into accurate predictions of late age‐related macular degeneration (AMD) may be limited by biomarker prevalence, subjective identification and competing risks from concurrent biomarkers. This study evaluates the prognostic performance of key optical coherence tomography (OCT) biomarkers for progression to late AMD, with colour fundus photography (CFP) as the reference standard. Methods: This retrospective study included 78 single eyes with intermediate AMD, propensity‐score matched by age and sex between converters and non‐converters to late AMD. Ten OCT biomarkers empirically derived from recent meta‐analysis, alongside CFP biomarkers of large drusen and pigmentary abnormality, were independently graded by three clinician‐researchers. Biomarkers' associated risk (odds ratios) and prognostic performance (area under the receiver operating characteristic curve (AUC), sensitivity, specificity) were evaluated for predicting late AMD. Results: The adjusted risk was highest for OCT‐detected nascent geographic atrophy, shallow irregular retinal pigment epithelium (RPE) elevations, drusenoid pigment epithelium detachment and RPE reflective abnormality (odds ratios, 6.66 [1.32, 42.71] to 28.27 [2.44, 545.3], p < 0.05). However, CFP‐detected pigmentary abnormalities demonstrated the highest individual prognostic accuracy (77.69 [68.11, 87.27]% AUC, p < 0.0001), with excellent sensitivity (92.31%) but moderate specificity (63.08%). Adding at least three OCT biomarkers was required to improve prognostic performance significantly (91.01 [84.66, 97.36]%, p < 0.0001), and at least eight additional biomarkers to yield both excellent sensitivity (94.62%) and specificity (90.77%). Conclusions: CFP‐detected pigmentary abnormality remains a mainstay of clinical AMD prognostication, likely due to its higher prevalence and interpretability than high‐risk OCT biomarkers. Integrating OCT biomarkers into clinical prognostic models is promising but complex and may require automated identification to aid efficiency.

29 November 2021 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
PDF file
MTMatt Trinh
Matt Trinh
MKMichael Kalloniatis
Michael Kalloniatis
LNLisa Nivison‐Smith
Lisa Nivison‐Smith
Purpose: There is growing interest in functional testing for early/intermediate age‐related macular degeneration (iAMD). However, systematic evaluation of existing clinical functional tests is lacking. This systematic review examines evidence for using clinical automated perimetry in routine assessment of early/iAMD. Recent findings: PubMed, Web of Science Core Collection, and Embase were searched from inception to October 2020 to answer, is there evidence of visual field defects in early/iAMD, and if so, are early/iAMD visual field defects linked to real‐world patient outcomes? Articles using clinical automated perimetry (commercially accessible and non‐modified devices/protocols) were included. Microperimetry was excluded as this has yet to be incorporated into clinical guidelines. The primary outcome was global visual field indices including mean deviation (MD), pattern standard deviation (PSD), mean sensitivity (MS) and frequency of defects. The secondary outcome was any real‐world patient outcome including quality of life and/or activities of daily living indices. Twenty‐six studies were eligible for inclusion and all studies were observational. There was consistent evidence of worsened MD, PSD, MS and frequency of defects for early/iAMD compared to normal eyes under photopic, low‐photopic and scotopic conditions. Meta‐analysis of studies using standard automated perimetry (SAP) under photopic conditions revealed worsened MD (−1.52dB [−2.27, −0.78 dB]) and MS (−1.47dB [−2, −0.94 dB]) in early/iAMD compared to normal eyes, representing large statistical effect sizes but non‐clinically meaningful reductions. There was insufficient data for meta‐analyses regarding other clinical automated perimetry protocols. Only one study assessed a real‐world patient outcome (on‐road driving performance), with no significant link to visual field outcomes in early/iAMD. Summary: Significant reduction of global visual field indices is present in early/iAMD, but not clinically meaningful using SAP under photopic conditions. Translational relevance of visual field outcomes to patient outcomes in early/iAMD remains unclear. Thus, SAP under photopic conditions is unlikely to be useful for routine assessment of early/iAMD.

3 July 2025 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Open access
MTMatt Trinh
Matt Trinh
ADAnnita Duong
Annita Duong
RCRene Cheung
Rene Cheung
SCSimon Chen
Simon Chen
DNDavid Ng
David Ng
ALAngelica Ly
Angelica Ly
Background: The updated simplified AREDS risk model predicts progression to late age‐related macular degeneration (AMD) by person, describing up to nine observations across both eyes and 10 annual risk scores (0–4, with/without reticular pseudodrusen [RPD]). This study proposes an abridged model to enable inter‐eye comparisons and potentially enhance clinical efficiency. Methods: This retrospective cohort study included 269 participants with early/intermediate AMD over 7 years. The full, person‐level updated simplified AREDS risk model was compared to eye‐level candidate risk models, derived by removing the least predictive biomarkers. The main outcomes were prognostic performance (AUC) and risk score separability ( χ 2 ). Results: At 1–3 years, the full model showed prognostic performance (AUC ± SE) up to 84.52% ± 5.93%, with overlap between most risk scores ( χ 2 ≤ 2.08). Removing large drusen and pigmentary abnormalities in the fellow eye, intermediate drusen in both eyes, and redefining RPD presence as eye‐specific maintained prognostic performance (up to 84.71% ± 4.72%). Assigning one point per retained biomarker, based on similar adjusted risks, improved risk score separability ( χ 2 ≥ 3.85, p < 0.05) while reducing the number of annual scores from 10 to five. Conclusions: The updated simplified AREDS risk model can be essentially halved without compromising prognostic performance by deriving eye‐specific biomarkers and assigning one point per biomarker (large drusen, pigmentary abnormalities, and RPD in the primary eye, and late AMD in the fellow eye). This eye‐level risk stratification may improve clinical efficiency and inter‐eye study designs when one eye is of particular interest. An example of 3‐year risks (scores 0–4) was ≈4%, 8%, 16%, 32%, and 64%.

7 July 2024 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
MTMatt Trinh
Matt Trinh
KOKelly O.
Kelly O.
MLMelanie La
Melanie La
ALAngelica Ly
Angelica Ly
Purpose: To assess the associations between physiology and demographics, non‐ocular pathology and pharmaceutical drug use against peri‐papillary retinal nerve fibre layer thickness (pRNFL T) and other optical coherence tomography (OCT) inner retinal measures in normal, healthy eyes. Methods: A retrospective, cross‐sectional study of 705 consecutive participants with bilateral normal, healthy optic nerves and maculae. PRNFL Ts, vertical cup/disc ratio (CDR), cup volume and macular ganglion cell layer‐inner plexiform layer (GCL‐IPL) Ts were extracted from Cirrus OCT scans, then regressed against predictor variables of participants' physiology and demographics (eye laterality, refraction, intraocular pressure [IOP], age, sex, race/ethnicity, etc.) and non‐ocular pathology and pharmaceutical drug use according to the World Health Organisation classifications. Associations were assessed for statistical significance ( p < 0.05) and clinical significance (|β| > 95% limits of agreement for repeated measures). Results: A multitude of non‐ocular pathology and pharmaceutical drug use were statistically and clinically significantly associated with deviations in standard OCT inner retinal measures, exceeding the magnitude of other factors such as age, IOP and race/ethnicity. Thinner inner retina and larger optic nerve cup measures were linked to use of systemic corticosteroids, sex hormones/modulators, presence of vasomotor/allergic rhinitis and other diseases and drugs (up to −29.3 [−49.88, −8.72] μm pRNFL T, 0.31 [0.07, 0.54] vertical CDR, 0.29 [0.03, 0.54] mm 3 cup volume and −10.18 [−16.62, −3.74] μm macular GCL‐IPL T; all p < 0.05). Thicker inner retina and smaller optic nerve cup measures were diffusely associated with use of antineoplastic agents, presence of liver or urinary diseases and other diseases and drugs (up to 67.12 [64.92, 69.31] μm pRNFL T, −0.31 [−0.53, −0.09] vertical CDR, −0.06 [−0.11, 0] mm 3 cup volume and 28.84 [14.51, 43.17] μm macular GCL‐IPL T; all p < 0.05). Conclusion: There are a multitude of systemic diseases and drugs associated with altered OCT inner retinal measures, with magnitudes far exceeding those of other factors such as age, IOP and race/ethnicity. These systemic factors should at least be considered during OCT assessments to ensure precise interpretation of normal versus pathological inner retinal health.