16 June 2021 in Journal of Geophysical Research: Atmospheres
Urban heat islands (UHIs) are one of the most typical changes to surface climate induced by human activities, which manifest as higher temperatures in urban areas than in their surroundings. In this study, we synthetically analyzed spatiotemporal features of daytime surface UHI intensity in east China over the period from 2009 to 2018 carried out with several offline simulations coupled with four land‐use data sets, and identified the causes of UHIs with two attribution methods. The results indicate that spatial variations of summer daytime UHI intensity in east China are dominated by variations in the efficiency of evaporating water (∼3°C) between urban and rural areas. Geographic variations of winter UHI intensity mainly depend on the urban‐rural contrast of heat storage capacity (∼1°C). Additionally, we found that forest‐covered rural areas have an extremely higher convection efficiency than urban areas and nonforest rural landscapes, resulting in a remarkable contribution to summer daytime UHI intensity (∼6°C). However, rural areas largely comprising croplands and grasslands evaporate water more efficiently, expanding summer daytime UHI intensity by approximately 3°C. The prominent capacity of heat storage in nonforest vegetation rural areas accounts for 1°C warming of winter daytime UHI intensity. The major discrepancy between the two attribution methods lies in the evapotranspiration performances of forest‐covered rural lands. Furthermore, the inter‐comparison of several modeling experiments for land‐use data sets suggests that the disparity in UHI intensity could increase by up to 0.4°C, which may exceed 1°C at the local scale.
21 August 2023 in Journal of Geophysical Research: Atmospheres
7 May 2024 in Journal of Geophysical Research: Atmospheres
31 July 2025 in Geophysical Research Letters
As the nexus of terrestrial water‐energy‐carbon exchange, evapotranspiration (ET) modulates ecosystem‐climate interactions, yet its biophysical responses to urbanization and climate change remain unclear. Using fully coupled Earth system modeling and flux tower observations, we disentangle radiative (surface available energy) and non‐radiative (advection‐sustained vapor gradients) controls on global ET. The decoupling factor, a pivotal biophysical regulator of land‐atmosphere coupling for ET, exhibits a climate‐vegetation latitudinal gradient spanning 0.1 (arid) to 0.5 (continental). Global warming enhances land‐atmosphere coupling, suppressing radiative contributions while amplifying non‐radiative influences. Urbanization reduces ET but tends to shift its dominant driver toward available energy, unlike rural areas dominated by advection‐sustained vapor gradients. The urban‐rural contrast in the radiative contributor intensifies at ∼0.3 W m−2 decade−1 (2.4 times that of the non‐radiative contributor) under RCP8.5, linked to a 60% slower decline in urban decoupling factor than rural areas. This study provides a fuller picture of the mechanistic understanding of ET.
4 July 2026 in Journal of Advances in Modeling Earth Systems
There have been significant wet biases in the simulation of precipitation over the Tibetan Plateau (TP) for a long time. One of the important reasons is that current numerical models cannot accurately describe the influence of small‐scale orography. In the orographic gravity wave drag (OGWD) parameterization used to describe small‐scale orographic effects, this study develops a high‐precision calculation method of sub‐grid mountain sharpness that varies with geographical areas to revise and optimize the current constant mountain sharpness parameter (results in a constant drag coefficient at the surface). Batch numerical experiments on precipitation over the TP are carried out using the Yin‐He Global Spectral Model. The results show that the newly calculated drag coefficient of revised OGWD scheme improves the simulation of precipitation and atmospheric circulation over the TP. The new mountain sharpness overall increases the OGWD over the TP on the westerly circulation. According to the vertical vorticity equation, changes in OGWD enhance the positive vorticity over the southern TP. Compared to the original scheme, the revised OGWD experiment exhibits a cyclonic circulation difference over the southern TP, which weakens the flow of water vapor into the TP. The water vapor budget of the main precipitation area over the western TP decreases by about 12.66%, thus reducing precipitation and wet biases over the western TP.
29 August 2022 in ESS Open Archive
The urban expansion-induced heat can deteriorate heat stress for urban dwellers, especially during heat waves. With a focus on the intra-urban variability of UHIs and thermal comfort, the urban parameterization within the CLM5 was modified to incorporate the LCZs framework to simulate urban climate during a HW event in the summer of 2013 in East China. The simulations were validated by observation data from a flux tower measurement site, conventional stations and automatic meteorological stations, which exhibits a reasonable agreement. The aim of this work was to investigate: 1) the variability of temperature and heat stress in relation to each urban LCZ, 2) the influence of intra-urban inhomogeneity on attributing factors of SUHII, 3) the response of CUHII and SUHII, urban thermal comfort and controlling factors of SUHII to HW. The results show that daytime and nighttime CUHII were highest in LCZ3 and LCZ1 areas, respectively. SUHII separately peaked in LCZ8 and LCZ1 areas during daytime and nighttime. Contrasts of CUHII and SUHII between urban classes could exceed 1.7℃ and 5.4℃ which varied with background climate and HW episode. Urban dwellers were exposed to the most serious heat stress in LCZ3 and LCZ1 areas over the north subtropical climate zone. The intra-urban heterogeneity resulted in the changes in dominant factors controlling SUHII that were modulated by local climate and HW intensity. Moreover, UHIs and thermal comfort were obviously affected by the occurrence of HW events such as the changes in CUHII for LCZ7 (1.0℃) and SUHII for LCZ8 (3.8℃).