31 March 2022 in Endoscopy
Background Multiple computer-aided systems for polyp detection (CADe) have been introduced into clinical practice, with an unclear effect on examiner behavior. This study aimed to measure the influence of a CADe system on reaction time, mucosa misinterpretation, and changes in visual gaze pattern. Methods Participants with variable levels of colonoscopy experience viewed video sequences (n = 29) while eye movement was tracked. Using a crossover design, videos were presented in two assessments, with and without CADe support. Reaction time for polyp detection and eye-tracking metrics were evaluated. Results 21 participants performed 1218 experiments. CADe was significantly faster in detecting polyps compared with participants (median 1.16 seconds [99 %CI 0.40–3.43] vs. 2.97 seconds [99 %CI 2.53–3.77], respectively). However, the reaction time of participants when using CADe (median 2.90 seconds [99 %CI 2.55–3.38]) was similar to that without CADe. CADe increased misinterpretation of normal mucosa and reduced the eye travel distance. Conclusions Results confirm that CADe systems detect polyps faster than humans. However, use of CADe did not improve human reaction times. It increased misinterpretation of normal mucosa and decreased the eye travel distance. Possible consequences of these findings might be prolonged examination time and deskilling. * These authors contributed equally to this work. Received: 19 September 2021 Accepted: 10 February 2022 Accepted Manuscript online: 14 February 2022 Article published online: 31 March 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
20 April 2023 in Endoscopy
Background Measurement of colorectal polyp size during endoscopy is mainly performed visually. In this work, we propose a novel polyp size measurement system (Poseidon) based on artificial intelligence (AI) using the auxiliary waterjet as a measurement reference. Methods Visual estimation, biopsy forceps-based estimation, and Poseidon were compared using a computed tomography colonography-based silicone model with 28 polyps of defined sizes. Four experienced gastroenterologists estimated polyp sizes visually and with biopsy forceps. Furthermore, the gastroenterologists recorded images of each polyp with the waterjet in proximity for the application of Poseidon. Additionally, Poseidon's measurements of 29 colorectal polyps during routine clinical practice were compared with visual estimates. Results In the silicone model, visual estimation had the largest median percentage error of 25.1 % (95 %CI 19.1 %–30.4 %), followed by biopsy forceps-based estimation: median 20.0 % (95 %CI 14.4 %–25.6 %). Poseidon gave a significantly lower median percentage error of 7.4 % (95 %CI 5.0 %–9.4 %) compared with other methods. During routine colonoscopies, Poseidon presented a significantly lower median percentage error (7.7 %, 95 %CI 6.1 %–9.3 %) than visual estimation (22.1 %, 95 %CI 15.1 %–26.9 %). Conclusion In this work, we present a novel AI-based method for measuring colorectal polyp size with significantly higher accuracy than other common sizing methods.
7 June 2021 in United European Gastroenterology Journal
Background: Artificial intelligence (AI) using deep learning methods for polyp detection (CADe) and characterization (CADx) is on the verge of clinical application. CADe already implied its potential use in randomized controlled trials. Further efforts are needed to take CADx to the next level of development.Aim: This work aims to give an overview of the current status of AI in colonoscopy, without going into too much technical detail.Methods: A literature search to identify important studies exploring the use of AI in colonoscopy was performed.Results: This review focuses on AI performance in screening colonoscopy summarizing the first prospective trials for CADe, the state of research in CADx as well as current limitations of those systems and legal issues.
2 August 2023 in Endoscopy
Background and study aims Artificial intelligence (AI)-based systems for computer-aided detection (CADe) of polyps receive regular updates and occasionally offer customizable detection thresholds, both of which impact their performance, but little is known about these effects. This study aimed to compare the performance of different CADe systems on the same benchmark dataset. Methods 101 colonoscopy videos were used as benchmark. Each video frame with a visible polyp was manually annotated with bounding boxes, resulting in 129 705 polyp images. The videos were then analyzed by three different CADe systems, representing five conditions: two versions of GI Genius, Endo-AID with detection Types A and B, and EndoMind, a freely available system. Evaluation included an analysis of sensitivity and false-positive rate, among other metrics. Results Endo-AID detection Type A, the earlier version of GI Genius, and EndoMind detected all 93 polyps. Both the later version of GI Genius and Endo-AID Type B missed 1 polyp. The mean per-frame sensitivities were 50.63 % and 67.85 %, respectively, for the earlier and later versions of GI Genius, 65.60 % and 52.95 %, respectively, for Endo-AID Types A and B, and 60.22 % for EndoMind. Conclusions This study compares the performance of different CADe systems, different updates, and different configuration modes. This might help clinicians to select the most appropriate system for their specific needs.