M. V. Shcherbakov

M. V. Shcherbakov

Auto-generated profile, based on publicly available information

M. V. Shcherbakov

Samara State Medical University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Stomatology for all / International Dental Review
Verified
Journal Article
Closed access
MSM.V. Shcherbakov
M.V. Shcherbakov
ABA.I. Bayrikov
A.I. Bayrikov

10 December 2021 in Bulletin of the Medical Institute "REAVIZ" (REHABILITATION, DOCTOR AND HEALTH)
Verified
Journal Article
Open access
PDF file
AIA. V. Ivaschenko
A. V. Ivaschenko
AYA. E. Yablokov
A. E. Yablokov
MSM. V. Shcherbakov
M. V. Shcherbakov
IBI. V. Bazhutova
I. V. Bazhutova
SVS. V. Vinnik
S. V. Vinnik
Relevance. According to a number of authors, it is known that full adaptation to complete removable dentures occurs within 3 months [3–5, 9]. The main criterion for patients getting used to removable dentures is the synchronization of the work of the masticatory muscles and, as a consequence, the normalization of the chewing function. The aim of the study was to evaluate the bioelectrical activity of the masticatory muscles in patients using the CSPP.Materials and methods. In patients of the control (n = 23) and main (n = 63) groups, electromyographic examination was performed using the electroneuromyographic system "Synapsis" (Neurotechnology, Russia). Registration of the bioelectric activity of the chewing muscles was carried out directly on the day of applying the prostheses, after 1 and 3 months, respectively.Results and discussion. The electromyographic indices of the masticatory muscles in the patients of the control group decreased within one month after the treatment and amounted to 231 ± 18.2 μV for the right and 229 ± 16.1 μV for the left proper chewing muscles. The values were also reduced for the right and left temporal muscles – 228 ± 15.2 μV and 225 ± 24.1 μV (p < 0.05). It should be noted that the electromyographic parameters in patients of the main group were comparable to the lower limit of the norm and amounted to 269 ± 16.5 μV and 256 ± 20.4 μV, respectively, after one month of treatment.Conclusions. In the treatment of dysfunction of the temporomandibular joint with the use of thermoplastic prostheses, an increase in the biopotentials of the masticatory muscles is observed. In the orthopedic treatment of patients with terminal dentition defects using thermoplastic prostheses, the electromyographic parameters of the masticatory muscles are most close to normal after 3 months of using these prostheses.

1 January 2021 in Russian Journal of Stomatology
Verified
Journal Article
Closed access
AIAnton Ivaschenko
Anton Ivaschenko
AYA.E. Yablokov
A.E. Yablokov
ANA.M. Nesterov
A.M. Nesterov
MSM.V. Shcherbakov
M.V. Shcherbakov
IBI.O. Buentsov
I.O. Buentsov
IBI.V. Bazhutova
I.V. Bazhutova
В статье описан анатомический эксперимент, определяющий затрачиваемое врачом время на одонтопрепарирование отдельных групп зубов. ЦЕЛЬ ИССЛЕДОВАНИЯ Выявить влияние человеческого фактора при проведении одонтопрепарирования. МАТЕРИАЛ И МЕТОДЫ В эксперименте группой врачей индивидуально выполнялось одонтопрепарирование 4.4 и 4.6 зубов. Данный выбор был сделан в пользу дистальной группы зубов. Выбор был обусловлен тем, что эти зубы расположены в дистальном отделе челюсти и являются наиболее труднодоступными для врача-стоматолога при проведении одонтопрепарирования. Момент касания стоматологическим инструментом отдельных сегментов фиксировался звукозаписывающим устройством. Впоследствии было оценено время сошлифовывания секторов препарированного зуба и была найдена взаимосвязь между временем обработки секторов на основе полученной видеозаписи и звуковой дорожки. Проанализированы зубы 4.4 и 4.6. В результате были получены числовые распределения, показывающие, каким анатомическим областям зуба (групп зубов) врач уделяет наибольшее внимание во время подготовки к протезированию. РЕЗУЛЬТАТЫ И ОБСУЖДЕНИЕ В конце статьи был сделан вывод, что при одонтопрепарировании врач больше внимания уделяет наиболее доступным участкам зуба и меньше — труднодоступным участкам, скрытым от глаза. Врач обрабатывает участки боковой поверхности зуба, которые легко видны и легкодоступны для него, в то время как боковые поверхности зуба, которые скрыты от глаз врача, менее подвержены манипуляциям.

25 September 2026 in Clinical Dentistry (Russia)
Verified
Journal Article
Closed access
VTV.P. Tlustenko
V.P. Tlustenko
SKS.S. Komlev
S.S. Komlev
VTV.S. Tlustenko
V.S. Tlustenko
ASA.V. Shmelev
A.V. Shmelev
MSM.V. Shcherbakov
M.V. Shcherbakov
AKA.K. Karapetyan
A.K. Karapetyan
Bar structures are widely used in the fixation of implant-supported removable prostheses in patients with complete tooth loss and are considered as one of the most stable methods of prosthesis stabilization. However, a number of problems related to mechanical, biological, and functional complications remain in clinical practice, which determines the relevance of their comprehensive analysis. The subject of this study is the clinical and biomechanical features of the fixation of prostheses on bar structures. The aim of the work is to review current data on fixation problems, identify key risk factors for complications, and determine the directions for their prevention. As a hypothesis, it is proposed that the frequency of complications is determined by a combination of biomechanical design parameters, manufacturing accuracy, the quality of hygienic care, and the level of technical support. The methodological basis of the study was an analytical review of domestic and foreign publications of recent years on the biomechanics of bar systems, clinical effectiveness, comparative analysis of alternative fixation methods, and the use of digital technologies in their production. The results of the analysis show that bar structures provide high stability of the prosthesis and even distribution of the occlusal load, but they are also highly sensitive to the accuracy of the fit, the condition of the retention elements, and the maintenance of hygiene. The most common complications include loosening of the screw fixation, wear of the clips, inflammatory changes in the periimplant tissues, and functional discomfort. The use of digital design and individualized implantation planning increases the predictability of results and reduces the risk of adverse outcomes. It is concluded that it is necessary to have a comprehensive approach to planning, manufacturing and subsequent support of bar fixation systems.

21 September 2025 in Clinical Dentistry (Russia)
Verified
Journal Article
Open access
PDF file
VTV.S. Tlustenko
V.S. Tlustenko
MSM.V. Shcherbakov
M.V. Shcherbakov
VTV.P. Tlustenko
V.P. Tlustenko
VKV.A. Koshelev
V.A. Koshelev
NNN.V. Nogina
N.V. Nogina
The main etiologic factor of periodontitis according to modern concepts is bacterial action followed by the immune response of the body and the production of proinflammatory cytokines. Genetic predisposition, lifestyle, and concomitant pathology complicate the course of the disease. Other risk factors include occlusal disorders leading to traumatic overload of the periodontium. However, to date, there are no convincing studies revealing the role and nature of occlusal factors influencing the development of periodontitis. The aim of the study is to assess the significance of occlusal disorders in the development of chronic generalized periodontitis of mild severity. Materials and methods. An observational study was conducted involving 45 people aged 25 to 45 years with identified occlusal disorders of the supercontact type in static and dynamic occlusions. The main group included 25 individuals with occlusal interferences against the background of chronic generalized periodontitis of mild severity, the comparison group consisted of 20 individuals with identified occlusal interferences without established periodontal pathology. To assess the condition of the periodontium, hygienic and periodontal indices were used, occlusal analysis was performed, the bioelectrical activity of the masticatory muscles was assessed using surface electromyography, and microcirculation in the periodontal tissues was studied using the rheoparodontography method. Results. According to the results of the study, the hygienic indices of individuals in the main group reflected an unsatisfactory level of oral hygiene, periodontal indices had significantly higher values in the main group. Rheographic characteristics of the microcirculatory bed showed statistically highly significant differences between the groups: the rheographic index was lower in the main group and amounted to 51.2±20.8 mΩ, in the comparison group — 82.5±14.8 mΩ (p<0.001). The vascular tone index and the peripheral resistance index were higher in the main group and amounted to 19.31% and 96.11%, respectively, in the comparison group — 14.48% and 76.62% (p<0.001), respectively. According to the results of the functional test with maximum compression in habitual occlusion, highly significant differences in the symmetry coefficients of opposite muscles on each side were established in the main group and the comparison group: for the right side, Td/Md was 0.64 and 0.75 (p=0.009), respectively, for the left, Ts/Ms was 0.68 and 0.79 (p=0.008), respectively. Conclusion. According to the data obtained, occlusal interferences in some cases cause changes in the microhemodynamics of the intact periodontium, but are compensated in most cases by its reserve forces. In the presence of an inflammatory process in the periodontium, occlusal disorders can be considered as a potential aggravating risk factor.