Todd Thorsen

Todd Thorsen

Auto-generated profile, based on publicly available information

Todd Thorsen

Massachusetts Institute of Technology

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ZWZhanhui Wang
Zhanhui Wang
MKMin-Cheol Kim
Min-Cheol Kim
MMManuel Marquez
Manuel Marquez
TTTodd Thorsen
Todd Thorsen
In this paper, we report on the development of a multilayer elastomeric microfluidic array platform for the high-throughput cell cytotoxicity screening of mammalian cell lines. Microfluidic channels in the platform for cell seeding are orthogonal to channels for toxin exposure, and within each channel intersection is a circular chamber with cell-trapping sieves. Integrated, pneumatically-actuated elastomeric valves within the device isolate the microchannel array within the device into parallel rows and columns for cell seeding and toxin exposure. As a demonstration of the multiplexing capability of the platform, a microfluidic array containing 576 chambers was used to screen three cell types (BALB/3T3, HeLa, and bovine endothelial cells) against a panel of five toxins (digitonin, saponin, CoCl2 , NiCl2 , acrolein). Evaluation of on-chip cell morphology and viability was carried out using fluorescence microscopy, with outcomes comparable to microtiter plate cytotoxicity assays. Using this scalable platform, cell seeding and toxin exposure can be carried out within a single microfluidic device in a multiplexed format, enabling high-density parallel cytotoxicity screening while minimizing reagent consumption.

2 October 2006 in Applied Physics Letters
Verified
Journal Article
Closed access
JUJohn Paul Urbanski
John Paul Urbanski
TTTodd Thorsen
Todd Thorsen
JLJeremy A. Levitan
Jeremy A. Levitan
MBMartin Z. Bazant
Martin Z. Bazant
This letter demonstrates dramatic improvements in flow rate and frequency range over conventional planar ac electro-osmotic (ACEO) pumps by exploiting three-dimensional (3D) stepped electrodes. A 3D ACEO pump was fabricated by electroplating steps on a symmetric electrode array and tested against a state-of-the-art asymmetric planar ACEO pump in a microfluidic loop. For all frequencies (0.1–100kHz), the 3D pump had a faster flow rate, in some cases by an order of magnitude. Their experimental results suggest that, after some optimization, mm/s velocities will be attainable with alternating battery voltages, which presents an exciting opportunity for microfluidics.

5 May 2007 in Natural Computing
Verified
Journal Article
Closed access
PDF file
WTWilliam Thies
William Thies
JUJohn Paul Urbanski
John Paul Urbanski
TTTodd Thorsen
Todd Thorsen
SASaman Amarasinghe
Saman Amarasinghe

29 November 2005 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JUJohn Paul Urbanski
John Paul Urbanski
WTWilliam Thies
William Thies
CRChristopher Rhodes
Christopher Rhodes
SASaman Amarasinghe
Saman Amarasinghe
TTTodd Thorsen
Todd Thorsen
Although microfluidic chips have demonstrated basic functionality for single applications, performing varied and complex experiments on a single device is still technically challenging. While many groups have implemented control software to drive the pumps, valves, and electrodes used to manipulate fluids in microfluidic devices, a new level of programmability is needed for end users to orchestrate their own unique experiments on a given device. This paper presents an approach for programmable and scalable control of discrete fluid samples in a polydimethylsiloxane (PDMS) microfluidic system using multiphase flows. An immiscible fluid phase is utilized to separate aqueous samples from one another, and a novel “microfluidic latch” is used to precisely align a sample after it has been transported a long distance through the flow channels. To demonstrate the scalability of the approach, this paper introduces a “general-purpose” microfluidic chip containing a rotary mixer and addressable storage cells. The system is general purpose in that all operations on the chip operate in terms of unit-sized aqueous samples; using the underlying mechanisms for sample transport and storage, additional sensors and actuators can be integrated in a scalable manner. A novel high-level software library allows users to specify experiments in terms of variables (i.e., fluids) and operations (i.e., mixes) without the need for detailed knowledge about the underlying device architecture. This research represents a first step to provide a programmable interface to the microfluidic realm, with the aim of enabling a new level of scalability and flexibility for lab-on-a-chip experiments.

25 August 2005 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AVAdam P. Vollmer
Adam P. Vollmer
RPRonald F. Probstein
Ronald F. Probstein
RGRichard Gilbert
Richard Gilbert
TTTodd Thorsen
Todd Thorsen
This paper describes a platform for real-time sensing of dissolved oxygen in a flowing microfluidic environment using an oxygen-sensitive luminescent dye (platinum octaethylporphyrin ketone) integrated into a micro-oxygenator device. Using a phase-based detection method, the luminescent decay lifetime of the dye was consistent with the linear Stern–Volmer relationship using both gaseous and aqueous samples. Maximum sensor resolution varied between 120–780 ppb across a range of dissolved oxygen (DO) concentrations ranging from 0–42.5 ppm. The sensor was subsequently used to determine the convective mass-transfer characteristics of a multi-layer polydimethylsiloxane (PDMS) microfluidic oxygenator. The membrane-based oxygenator showed excellent agreement with an analytical convection model, and the integrated oxygen sensor was accurate across a wide range of tested flow rates (0.05–5 mL min−1). The device is unique for its ease of fabrication and highly flexible configuration, as well as the novel incorporation of oxygen delivery and detection in a single micro-device. Potential applications include tissue engineering, cell culturing, and miniaturized bio-assays that require the delivery and/or detection of precise quantities of oxygen within a microfluidic construct.

11 June 2009 in Analytical Chemistry
Verified
Journal Article
Open access
Raymond LamRaymond Lam
Raymond Lam
MKMin-Cheol Kim
Min-Cheol Kim
TTTodd Thorsen
Todd Thorsen
In this manuscript, we report on the culture of anaerobic and aerobic species within a disposable multilayer polydimethylsiloxane (PDMS) microfluidic device with an integrated differential oxygenator. A gas-filled microchannel network functioning as an oxygen−nitrogen mixer generates differential oxygen concentration. By controlling the relative flow rate of the oxygen and nitrogen input gases, the dissolved oxygen (DO) concentration in proximal microchannels filled with culture media are precisely regulated by molecular diffusion. Sensors consisting of an oxygen-sensitive dye embedded in the fluid channels permit dynamic fluorescence-based monitoring of the DO concentration using low-cost light-emitting diodes. To demonstrate the general utility of the platform for both aerobic and anaerobic culture, three bacteria with differential oxygen requirements (E. coli, A. viscosus, and F. nucleatum), as well as a model mammalian cell line (murine embryonic fibroblast cells (3T3)), were cultured. Growth characteristics of the selected species were analyzed as a function of eight discrete DO concentrations, ranging from 0 ppm (anaerobic) to 42 ppm (fully saturated).